background image

17

17 August, 2018

7039-184A

2100 Millennium AU Wood Appliance

B. Door Handle Assembly

Figure 17.1

Install spring handle using a counter-clockwise motion until 

the spring  handle has a 51mm clearance from bend of 

door hand rod 

(Figure 17.1)

.

 

51mm clearance is 

required from bend in 

door handle rod to 

end of spring handle

Spring 

handle

Door handle

Summary of Contents for 21M-ACC-AU

Page 1: ...me room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable...

Page 2: ...ey 10 B Minimum Height of Flue System Exit 11 C Chimney Termination Requirements 12 D General Flue System Instructions 13 E Chimney Height Rise and Run 13 F Installing Chimney Components 13 G Proper D...

Page 3: ...in a manner inconsistent with operating instructions in this manual NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or pr...

Page 4: ...d evacuation plan consisting of at least two escape routes 5 A plan to deal with a chimney fire as follows 6 In the event of a chimney fire a Evacuate the house immediately b Notify fire department C...

Page 5: ...d Reciprocating saw Pliers Hammer Phillips screwdriver Flat blade screwdriver Plumb line Level Misc screws and nails Framing material High temp caulking material Gloves Framing square Electric drill a...

Page 6: ...er the appliance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That...

Page 7: ...Appliance 501mm 745mm 618mm 677mm Figure 7 1 Front View Figure 7 3 Side View 533mm 600mm 600mm 699mm 233mm 343mm Figure 7 2 Top View 300mm 93mm 170mm 3 Dimensions and Clearances A Appliance Dimensions...

Page 8: ...ures 9 1 and 9 2 on page 9 A Floor Protector can include ceramic tiles with grouted joints fixed directly onto a wooden floor or a sheet of toughened glass panel steel or any other non combustible mat...

Page 9: ...0 DOUBLE WALL PIPE A B C D E F G H 808 1228 I J 1620 K L Figure 9 1 Figure 9 3 Figure 9 2 D Clearances to Combustibles G D E H C A I B F F J J G G L L K K NOTE Service Space In order to replace the tu...

Page 10: ...ould Install through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This m...

Page 11: ...re 3000mm 3000mm 3000mm or less more than 3000mm 600mm minimum NOTICE Chimney performance may vary Trees buildings roof lines and wind conditions affect performance Chimney height may need adjustment...

Page 12: ...s on page 13 for termination height The option of outer casing slips to be taken into account 6 Flash the outer casing to the roof material with the appropriate approved flashing 7 If using an outer i...

Page 13: ...ustrated 6 Once the Flue Mounted Shield is fitted in position onto either of the two lower mounting brackets check to ensure a large gap is not present between the top of the wood fire and the base of...

Page 14: ...imum 25mm gap between flue pipe casing combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing Roof Line Inner Casing 200m...

Page 15: ...e of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe ADD Cowl AS NZS2918 2001 Un tested...

Page 16: ...s show in Figure 16 1 If that is the case you will need to order SRV7033 041 which includes a cover plate and sealing rope as shown in Figure 16 2 The goal is to seal the pedestal so no room air can l...

Page 17: ...ndle Assembly Figure 17 1 Install spring handle using a counter clockwise motion until the spring handle has a 51mm clearance from bend of door hand rod Figure 17 1 51mm clearance is required from ben...

Page 18: ...AZARDOUS CONDITIONS WHERE SUCH ACTION IS CONSIDERED THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTION CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE IN...

Page 19: ...ing Date Active R IMPORTANT THIS IS DATED INFORMATION When requesting service or replacement parts for your appliance please provide model number and serial number All parts listed in this manual may...

Page 20: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deal...