background image

Page  2

7037-141B

March 28, 2012

R

2100 & 4300 Millennium ACC Wood Burner

Hearth & Home Technologies welcomes you to our tradition 

of excellence!  In choosing a Quadra-Fire appliance, you 

have our assurance of commitment to quality, durability, and 

performance.
This commitment begins with our research of the market, 

including ‘Voice of the Customer’ contacts, ensuring we 

make products that will satisfy your needs. Our Research 

and  Development  facility  then  employs  the  world’s  most 

advanced technology to achieve the optimum operation of 

our stoves, inserts and fireplaces.  And yet we are old-fash

-

ioned when it comes to craftsmanship.  Each unit is meticu-

lously fabricated and surfaces are hand-finished for lasting 

beauty and enjoyment.  Our pledge to quality is completed 

as each model undergoes a quality control inspection.    

We wish you and your family many years of enjoyment in 

the warmth and comfort of your hearth appliance.  Thank 

you for choosing Quadra-Fire.

4300 MILLENNIUM ACC

762mm

383mm

271mm

475mm

373mm

660mm

247mm

330mm

CL

292mm

527mm

406mm

CL

L

C

729mm

668mm

170mm

108mm 

Outside Air 

Connection

Fig. 2 - Quadra-Fire 4300 Millenium ACC Wood Burner Dimensions

room for .14 x .875” S/N

1.5” x .375 Barcode Label

JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

2012 2013 2014

INSTALLATION 

DATE

MILLENNIUM ACC WOODFIRE COMPLIANCE LABEL

R

SERIAL NO. 

007037

7037-147

This appliance has been TESTED TO AS/NZS4013 for Softwood by Applied Research Services Ltd. Report # 07/1717                   Date tested: November 2007
This appliance has been TESTED TO AS/NZS4013 for Hardwood by HRL Technology Report # HCMG/12/016                                 Date tested: March 2012

  

MODEL  QUADRA-FIRE 4300 MILLENNIUM ACC

BURN ONLY WOOD WITH A MOISTURE CONTENT LESS THEN 25% (dry 

basis).

Wetbacks are NOT an approved option and must not be fitted.

Hearth & Home Technologies, 1445 North Highway, Colville, WA 

99114, United States of America.

OVERALL AVERAGE EFFICIENCY 

TESTED TO AS/NZS 4012

AVERAGE PARTICULATE EMISSION FACTOR 

TESTED TO AS/NZS 4013

MAXIMUM AVERAGE HEAT OUTPUT 

APPROVED FUEL

WETBACK - ALL MODELS

MANUFACTURED BY

PERFORMANCE MAY VARY FROM TEST VALUES DEPENDING ON ACTUAL 

OPERATING CONDITIONS.

SOFTWOOD

71%

0.4 g/kg

10 kW

HARDWOOD

78%

2.5 g/kg

11.8 kW

U.S. ENVIRONMENTAL PROTECTION AGENCY

Export stove. May not be operated within the United States.

Summary of Contents for 21M-ACC-NZ

Page 1: ...a ceiling angle greater than 30 refer to Fig 6 7 and AS NZS 2918 2001 4 6 3 b Ceiling Plate may vary in size depending on ceiling angle Please specify ceiling pitch prior to ordering the ceiling plate...

Page 2: ...mm 660mm 247mm 330mm C L 292mm 527mm 406mm C L L C 729mm 668mm 170mm 108mm Outside Air Connection Fig 2 Quadra Fire 4300 Millenium ACC Wood Burner Dimensions roomfor 14x 875 S N 1 5 x 375BarcodeLabel...

Page 3: ...ONFACTORBURNINGSOFTWOOD WHENTESTEDINACCORDANCEWITHAS NZS4013 MAXIMUMAVERAGEHEATOUTPUTBURNINGSOFTWOOD APPROVEDFUEL WETBACK ALLMODELS MANUFACTUREDBY PERFORMANCEMAYVARYFROMTESTVALUESDEPENDINGONACTUAL OPE...

Page 4: ...0 4300 A Min clearance from firebox to rear wall 150 200 B Min clearance from firebox to side wall 550 400 C Min distance from firebox opening to floor protector front 300 300 D Min distance from fire...

Page 5: ...is being used position now Place the firebox on the floor protector to suit the minimum installation clearances See Fig 3 or 4 2 Seismically restrain the firebox and the floor protector to the floor...

Page 6: ...t roof penetration see NZ Building Code E2 Acceptable Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition...

Page 7: ...sing cover is necessary minimum 25mm gap between flue pipe casing combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing...

Page 8: ...b Fig 4 6 downward distance of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing A Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe Fig 7...

Page 9: ...legs from the bracket 5B leaving the entral tongue to locate inside the flue outlet only Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will mount lower ont...

Page 10: ...MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MODIFICATION OF THE APPLI...

Page 11: ...March 28 2012 7037 141B Page 11 R 2100 4300 Millennium ACC Wood Burner Homeowner Notes...

Page 12: ...Page 12 7037 141B March 28 2012 R 2100 4300 Millennium ACC Wood Burner Service And Maintenance Log Date of Service Performed By Description of Service...

Page 13: ...ACC STOVE DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these...

Reviews: