background image

March 28, 2012

7037-141B

Page  3

R

2100 & 4300 Millennium ACC Wood Burner

2100 (NZ-SOFTWOOD) MILLENNIUM ACC

709mm

342mm

235mm

432mm

324mm

594mm

219mm

297mm

CL

CL

292mm

406mm

CL

108mm 

Outside Air 

Connection

527mm

671mm

618mm

170mm

Fig. 1 - Quadra-Fire 2100 Millenium ACC Wood Burner Dimensions

room for .14 x .875” S/N

1.5” x .375 Barcode Label

JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

2012 2013 2014

INSTALLATION 

DATE

MILLENNIUM ACC WOODFIRE COMPLIANCE LABEL

R

SERIAL NO. / NUMÉRO DE SÉRIE / SERIENUMMER

007036

7039-145C

This appliance has been TESTED TO AS/NZS4013 by Applied Research Services Ltd. Report # 07/1716

Date tested: November 2007

ECan Authorisation Number 

     083786 

 

ECan Expiry Date  

24/10/2013

MODEL  QUADRA-FIRE 2100 MILLENNIUM ACC

72%

0.6 g/kg

9 kW

BURN ONLY SOFTWOOD WITH A MOISTURE CONTENT LESS THEN 

25% (dry basis).

Wetbacks are NOT an approved option and must not be fitted.

Hearth & Home Technologies, 1445 North Highway, Colville, WA 

99114, United States of America.

OVERALL AVERAGE EFFICIENCY BURNING SOFTWOOD

WHEN TESTED IN ACCORDANCE WITH AS/NZS 4012

AVERAGE PARTICULATE EMISSION FACTOR BURNING SOFTWOOD

WHEN TESTED IN ACCORDANCE WITH AS/NZS 4013

MAXIMUM AVERAGE HEAT OUTPUT BURNING SOFTWOOD

APPROVED FUEL

WETBACK - ALL MODELS

MANUFACTURED BY

PERFORMANCE MAY VARY FROM TEST VALUES DEPENDING ON ACTUAL 

OPERATING CONDITIONS.

U.S. ENVIRONMENTAL PROTECTION AGENCY

Export stove. May not be operated within the United States.

JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

2012 2013 2014

INSTALLATION 

DATE

MILLENNIUM ACC WOODFIRE COMPLIANCE LABEL

R

SERIAL NO. 

007044

7039-148

This appliance has been TESTED TO AS/NZS4013 for Hardwood by HRL Technology Report # HCMG/12/014  Date tested: March 2012

MODEL  QUADRA-FIRE 2100 MILLENNIUM ACC

81%

2.0 g/kg

9.1 kW

BURN ONLY HARDWOOD WITH A MOISTURE CONTENT LESS THEN 

25% (dry basis).

Wetbacks are NOT an approved option and must not be fitted.

Hearth & Home Technologies, 1445 North Highway, Colville, WA 

99114, United States of America.

OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD

  TESTED TO AS/NZS 4012

AVERAGE PARTICULATE EMISSION FACTOR BURNING HARDWOOD

TESTED TO AS/NZS 4013

MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD

APPROVED FUEL

WETBACK - ALL MODELS

MANUFACTURED BY

PERFORMANCE MAY VARY FROM TEST VALUES DEPENDING ON ACTUAL 

OPERATING CONDITIONS.

U.S. ENVIRONMENTAL PROTECTION AGENCY

Export stove. May not be operated within the United States.

2100 (AU-HARDWOOD) MILLENNIUM ACC

Summary of Contents for 21M-ACC-NZ

Page 1: ...a ceiling angle greater than 30 refer to Fig 6 7 and AS NZS 2918 2001 4 6 3 b Ceiling Plate may vary in size depending on ceiling angle Please specify ceiling pitch prior to ordering the ceiling plate...

Page 2: ...mm 660mm 247mm 330mm C L 292mm 527mm 406mm C L L C 729mm 668mm 170mm 108mm Outside Air Connection Fig 2 Quadra Fire 4300 Millenium ACC Wood Burner Dimensions roomfor 14x 875 S N 1 5 x 375BarcodeLabel...

Page 3: ...ONFACTORBURNINGSOFTWOOD WHENTESTEDINACCORDANCEWITHAS NZS4013 MAXIMUMAVERAGEHEATOUTPUTBURNINGSOFTWOOD APPROVEDFUEL WETBACK ALLMODELS MANUFACTUREDBY PERFORMANCEMAYVARYFROMTESTVALUESDEPENDINGONACTUAL OPE...

Page 4: ...0 4300 A Min clearance from firebox to rear wall 150 200 B Min clearance from firebox to side wall 550 400 C Min distance from firebox opening to floor protector front 300 300 D Min distance from fire...

Page 5: ...is being used position now Place the firebox on the floor protector to suit the minimum installation clearances See Fig 3 or 4 2 Seismically restrain the firebox and the floor protector to the floor...

Page 6: ...t roof penetration see NZ Building Code E2 Acceptable Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition...

Page 7: ...sing cover is necessary minimum 25mm gap between flue pipe casing combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing...

Page 8: ...b Fig 4 6 downward distance of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing A Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe Fig 7...

Page 9: ...legs from the bracket 5B leaving the entral tongue to locate inside the flue outlet only Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will mount lower ont...

Page 10: ...MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MODIFICATION OF THE APPLI...

Page 11: ...March 28 2012 7037 141B Page 11 R 2100 4300 Millennium ACC Wood Burner Homeowner Notes...

Page 12: ...Page 12 7037 141B March 28 2012 R 2100 4300 Millennium ACC Wood Burner Service And Maintenance Log Date of Service Performed By Description of Service...

Page 13: ...ACC STOVE DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these...

Reviews: