7037-141B

March 28, 2012

R

2100 & 4300 Millennium ACC Wood Burner

 

GENERAL INSTRUCTIONS FOR FLUE SYSTEM

 

1.QF.1D

 

 

 

 Flue pipe installed crimp/narrow end down

 

 Outer casings installed crimped/narrow end up. (Critical when exposed above the roof)

 

 Inner casings - direction not critical

 

 Flue pipes   - seal all joints including firebox spigot.

 

- fix with a minimum of 3 stainless steel rivets

 

 Flue pipe spacers - affix to flue pipe

 

 Flue system termination point - 

Refer to AS/NZS 2918:2001 4.9.1, see Fig. 9.

 

 Flue pipe shall extend not less than 4.6m above top of the floor protector as per

 

AS/NZS 2918:2001 4.9.1(a)

 

 Façade or chase systems  -  same rule applies as above.

 

 Roof penetration and flashing method refer to NZ Building Code E2.(From 01/07/05)

 

 

 

Note: These instructions apply to 150mm diameter flue pipe systems as tested to

 

AS/NZS 2918:2001

 

 

 

1.  Either locate the appliance in position or by measuring at the ceiling mark the flue pipe centre 

position. Check that the outer casing is unobstructed through the attic space or roof area.

 

2.  Spike the centre with a nail. Transfer this position to the next surface above. Plumb bob/laser.

 

3.  Cut out the ceiling penetration hole – square or rectangle – short axis equals outer casing 

diameter plus 50mm, long axis as required. See Table 5 . Perform the same at the roof 
penetration.

 

4.  Frame out the hole with minimum  75 x 50 timber or as required  for roofing material. Minimum 

requirement at roof penetration see NZ Building Code E2 Acceptable Solution (from 01/07/05).

 

5.  Install the outer casing so that :-

 

(i) 

lower end is flush with the underside of the ceiling material and

 

(ii) 

with the addition of metal “L” brackets, affix to the outer casing at 90 degrees secure the outer 

casing centrally to the ceiling and roof nogs.  Alternatively substitute the “L” brackets for 25mm 
thick non heat sensitive packers. Secure the outer casing through the packers with horizontal 
fixings to the nogs. Refer to the General Instruction for termination height. The option of outer 
casing slips to be taken into account.

 

6.  Flash the outer casing to the roof material with the appropriate approved flashing.

 

7.  If using an outer/inner casing combination, now install the inner casing ensuring it extends a 

minimum 200mm above the high side of the roof penetration. If not using a combination see ‘11’ 
below.

 

8.  Refer to Firebox Installation, points 1 & 2.

 

9.  Prepare the ceiling plate and place upside down over the flue spigot.

 

10. Install the flue pipes by preferred method – either up or down the outer casing. Affix each length 

per the notes in General Instructions (above). Extend the flue pipe  above the outer

 

casing to suit the casing cover/cowl assembly.

 

11. If the inner casing has not been installed, install now. Refer to 7 above  for minimum height.

 

12. Install the cowl assembly, i.e. Top spacer, casing cover and cowl.

 

13. Position and secure the ceiling plate with the screws and spacers.

 

14. Wipe the flue pipe to remove finger marks.

 

15. Refer to Firebox Installation, point 3.

 

16. If flue offset is required, refer to AS/NZS 2918:2001 4.1

 

Summary of Contents for 21M-ACC-NZ

Page 1: ...a ceiling angle greater than 30 refer to Fig 6 7 and AS NZS 2918 2001 4 6 3 b Ceiling Plate may vary in size depending on ceiling angle Please specify ceiling pitch prior to ordering the ceiling plate...

Page 2: ...mm 660mm 247mm 330mm C L 292mm 527mm 406mm C L L C 729mm 668mm 170mm 108mm Outside Air Connection Fig 2 Quadra Fire 4300 Millenium ACC Wood Burner Dimensions roomfor 14x 875 S N 1 5 x 375BarcodeLabel...

Page 3: ...ONFACTORBURNINGSOFTWOOD WHENTESTEDINACCORDANCEWITHAS NZS4013 MAXIMUMAVERAGEHEATOUTPUTBURNINGSOFTWOOD APPROVEDFUEL WETBACK ALLMODELS MANUFACTUREDBY PERFORMANCEMAYVARYFROMTESTVALUESDEPENDINGONACTUAL OPE...

Page 4: ...0 4300 A Min clearance from firebox to rear wall 150 200 B Min clearance from firebox to side wall 550 400 C Min distance from firebox opening to floor protector front 300 300 D Min distance from fire...

Page 5: ...is being used position now Place the firebox on the floor protector to suit the minimum installation clearances See Fig 3 or 4 2 Seismically restrain the firebox and the floor protector to the floor...

Page 6: ...t roof penetration see NZ Building Code E2 Acceptable Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition...

Page 7: ...sing cover is necessary minimum 25mm gap between flue pipe casing combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing...

Page 8: ...b Fig 4 6 downward distance of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing A Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe Fig 7...

Page 9: ...legs from the bracket 5B leaving the entral tongue to locate inside the flue outlet only Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will mount lower ont...

Page 10: ...MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MODIFICATION OF THE APPLI...

Page 11: ...March 28 2012 7037 141B Page 11 R 2100 4300 Millennium ACC Wood Burner Homeowner Notes...

Page 12: ...Page 12 7037 141B March 28 2012 R 2100 4300 Millennium ACC Wood Burner Service And Maintenance Log Date of Service Performed By Description of Service...

Page 13: ...ACC STOVE DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these...

Reviews: