2100 Millennium NZ Wood Appliance

Important Safety Information .............3

A. Appliance Certification

. . . . . . . . . . . . . . . . . . . . . . . 3

B. BTU & Efficiency Specifications

  . . . . . . . . . . . . . . . 3

C. Glass Specifications

  . . . . . . . . . . . . . . . . . . . . . . . . 3

D. Non-Combustible Materials

. . . . . . . . . . . . . . . . . . . 3

E. Combustible Materials

. . . . . . . . . . . . . . . . . . . . . . . 3

Getting Started ....................................4

A. Design and Installation Considerations . . . . . . . . . . 4

B. Fire Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

C. Negative Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . 4

D. Tools And Supplies Needed  . . . . . . . . . . . . . . . . . . 5

E. Inspection of Appliance and Components . . . . . . . . 5

F. Removal of Appliance from Shipping Materials

. . . . 5

G. Install Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Dimensions and Clearances ..............7

A. Appliance Dimensions . . . . . . . . . . . . . . . . . . . . . . . 7

B. Hearth Protection Requirements . . . . . . . . . . . . . . . 8

C. Firebox Installation

  . . . . . . . . . . . . . . . . . . . . . . . . . 8

D. Clearances to Combustibles

. . . . . . . . . . . . . . . . . . 9

Chimney Systems .............................10

A. Locating Your Appliance & Chimney . . . . . . . . . . . 10

B. Minimum Height of Flue System Exit

  . . . . . . . . . . 11

C. Chimney Termination Requirements . . . . . . . . . . . 12

D. General Flue System Instructions . . . . . . . . . . . . . 13

E. Chimney Height / Rise and Run  . . . . . . . . . . . . . . 13

F. Installing Chimney Components  . . . . . . . . . . . . . . 13

G. Proper Draft  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

H. Tested Flue Systems. . . . . . . . . . . . . . . . . . . . . . . 14

I. Un-Tested Flue Systems

. . . . . . . . . . . . . . . . . . . . . 15

Appliance Set-Up ..............................16

A. Outside Air Kit Installation   . . . . . . . . . . . . . . . . . . 16

B. Door Handle Assembly

  . . . . . . . . . . . . . . . . . . . . . 17

AS/NZS 2918:2001 General Notes ...18

Accessory List ..................................19

Quadra-Fire is a registered trademark of Hearth & Home Technologies.

TABLE OF CONTENTS

Safety Alert Key:

•  DANGER!

 Indicates a hazardous situation which, if not avoided will result in death or serious injury.

•  WARNING!

 Indicates a hazardous situation which, if not avoided may result in death or serious injury.

•  CAUTION!

 Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury.

•  NOTICE:

 Indicates practices which may cause damage to the appliance or to property.

Summary of Contents for 21M-ACC-NZ

Page 1: ...same room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away WARNING Fire Risk For use with solid wood fuel only Other fuels may over fire and generate poisonous gases i e carbon monoxide Do not store or use gasoline or other flammable vapors a...

Page 2: ...mney 10 B Minimum Height of Flue System Exit 11 C Chimney Termination Requirements 12 D General Flue System Instructions 13 E Chimney Height Rise and Run 13 F Installing Chimney Components 13 G Proper Draft 13 H Tested Flue Systems 14 I Un Tested Flue Systems 15 5 Appliance Set Up 16 A Outside Air Kit Installation 16 B Door Handle Assembly 17 6 AS NZS 2918 2001 General Notes 18 7 Accessory List 19...

Page 3: ...e this wood appliance in a manner inconsistent with operating instructions in this manual NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or price without notice Improper installation adjustment alteration service or maintenance can cause injury or property damage For assistance or additional information consult a quali...

Page 4: ...ed evacuation plan consisting of at least two escape routes 5 A plan to deal with a chimney fire as follows 6 In the event of a chimney fire a Evacuate the house immediately b Notify fire department C Negative Pressure Negative pressure results from the imbalance of air available for the appliance to operate properly It can be strongest in lower levels of the house Causes include Exhaust fans kitc...

Page 5: ...ded Reciprocating saw Pliers Hammer Phillips screwdriver Flat blade screwdriver Plumb line Level Misc screws and nails Framing material High temp caulking material Gloves Framing square Electric drill and bits Safety glasses Tape measure 7 16 socket or wrench 1 2 3 4 in length 6 or 8 self drilling screws Installation and use of any damaged appliance Modification of the appliance Installation other...

Page 6: ...ard doit être utilisée par l installateur en plus et non au lieu des instructions contenues dans ce manuel d installation Client __________________________________________________________________________ Date d installation __________________________________________________________________________ Lot Adresse __________________________________________________________________________ Emplacement su...

Page 7: ...d Appliance 501mm 745mm 618mm 677mm Figure 7 1 Front View Figure 7 3 Side View 533mm 600mm 600mm 699mm 233mm 343mm Figure 7 2 Top View 300mm 93mm 170mm 3 Dimensions and Clearances A Appliance Dimensions NOTE Flue Collar size is 152mm inside diameter ID ...

Page 8: ...tighten 4 Fit timber trim pedestal edging to front and back of base optional WARNING Fire Risk Hearth pads must be installed exactly as specified High temperatures or hot embers may ignite concealed combustibles Fire Risk Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire WARNING NOTE The minimum Floor Protector sizes are specified in the clearan...

Page 9: ...300 DOUBLE WALL PIPE A B C D E F G H 860 1280 I J 1510 K L Figure 9 1 Figure 9 3 Figure 9 2 D Clearances to Combustibles G D E H C A I B F F J J G G L L K K NOTE Service Space In order to replace the tube channel assembly a clearance of 483mm is required on the right side of appliance in order to remove the tubes with the appliance in place If space is not available the appliance will have to be d...

Page 10: ...should Install through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent s...

Page 11: ...ture 3000mm 3000mm 3000mm or less more than 3000mm 600mm minimum NOTICE Chimney performance may vary Trees buildings roof lines and wind conditions affect performance Chimney height may need adjustment if smoking or overdraft occurs NOTICE Locating the appliance in a basement or in a location of considerable air movement can cause intermittent smoke spillage from appliance Do not locate appliance ...

Page 12: ...ns on page 13 for termination height The option of outer casing slips to be taken into account 6 Flash the outer casing to the roof material with the appropriate approved flashing 7 If using an outer inner casing combination now install the inner casing ensuring it extends a minimum 200mm above the high side of the roof penetration If not using a combination see 11 below C Chimney Termination Requ...

Page 13: ...nce the Flue Mounted Shield is fitted in position onto either of the two lower mounting brackets check to ensure a large gap is not present between the top of the wood fire and the base of the Flue Mounted Shield as this may result in a hot spot on the rear wall directly behind the flue outlet If your wood fire has a lift off top grill the Flue Mounted Shield should be raised sufficiently to enabl...

Page 14: ...nimum 25mm gap between flue pipe casing combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing Roof Line Inner Casing 200mm above roof line Outer Casing Inner Casing 25 Internal Swage 25 25 12 5 Vented Ceiling Plate Flue Pipe C L C L Floor Protector as per AS NZS 2918 2001 Figure 14 1 ...

Page 15: ...f casing and 3 x ø flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing Ceiling Plate Batten A 3 x Ø flue pipe Ceiling flue pipe Ø ADD Cowl AS NZS2918 2001 Un tested flue with sloped ceiling penetration greater than 30 from horizontal A 25mm 4 6 3 b Fig 4 6 3 x ø flue from active flue to heat sensitive surface Casing Cover Spider Bracket Approved Flashing A Cei...

Page 16: ...as show in Figure 16 1 If that is the case you will need to order SRV7033 041 which includes a cover plate and sealing rope as shown in Figure 16 2 The goal is to seal the pedestal so no room air can leak into the pedestal or for cold air infiltration A Outside Air Kit Installation A source of air oxygen is necessary in order for combustion to take place Whatever combustion air is consumed by the ...

Page 17: ...Handle Assembly Figure 17 1 Install spring handle using a counter clockwise motion until the spring handle has a 51mm clearance from bend of door hand rod Figure 17 1 51mm clearance is required from bend in door handle rod to end of spring handle Spring handle Door handle ...

Page 18: ... HAZARDOUS CONDITIONS WHERE SUCH ACTION IS CONSIDERED THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTION CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARNING DO NOT USE FLAMMABLE LIQUIDS...

Page 19: ...19 October 23 2018 7039 186A 2100 Millennium NZ Wood Appliance 7 Accessory List ...

Page 20: ...te purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dealership purchased from ________________________________________ Dealer phone _1 _____ _____ ______ Notes ________________________________________________________________________________________ _____...