2700 INSERT WOOD INSERT

Automatic Combustion Control (ACC)

Model(s):

27I-ACC

O-T L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

  

HOT 

SURFACES!

 

 

Glass and other surfaces are hot 

 

 

during operation AND cool down. 

Hot glass will cause burns.

• 

Do not touch glass until it is cooled

• 

NEVER allow children to touch glass

• 

Keep children away

• 

CAREFULLY SUPERVISE children in same room as 
fi replace.

• 

Alert children and adults to hazards of high temperatures

• 

High temperatures may ignite clothing or other 
fl ammable materials.

• 

Keep clothing, furniture, draperies and other fl ammable 
materials away.

 WARNING

If the information in these instruc-
tions is not followed exactly, a 
fi re may result causing property 
damage, personal injury, or death.

 

•  Do not store or use gasoline or other fl am-

mable vapors and liquids in the vicinity of 
this or any other appliance.

•  Do not overfi re - If heater or chimney con-

nector glows, you are overfi ring. Overfi ring 
will void your warranty.

•  Comply with all minimum clearances to 

combustibles as specifi ed.  Failure to 
comply may cause house fi re.

WARNING

Fire Risk.

For use with solid wood fuel only.
Other fuels may overfi re and generate 
poisonous gases (i.e. carbon monoxide).

Installation and service of this appliance should 
be performed by qualifi ed personnel.  Hearth & 
Home Technologies recommends NFI certifi ed 
professionals, or technicians supervised by an 
NFI certifi ed professional.

WARNING

Installation Manual

Installation & Appliance Set-Up

INSTALLER: Leave this manual with party responsible for use and operation. 
OWNER: Retain this manual for future reference. 

NOTICE: DO NOT DISCARD THIS MANUAL

NOTE

To obtain a French translation of this manual, please contact 
your dealer or visit www.quadrafi re.com

Pour obtenir une traduction française de ce manuel, s’il vous 
plaît contacter votre revendeur ou visitez www.quadrafi re.com

Summary of Contents for 27I-ACC

Page 1: ...in the vicinity of this or any other appliance Do not overfire If heater or chimney con nector glows you are overfiring Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire WARNING Fire Risk For use with solid wood fuel only Other fuels may overfire and generate poisonous gases i e carbon monoxide Installation and...

Page 2: ...Appliance and Components 5 F Install Checklist 6 3 Dimensions and Clearances A Appliance Dimensions 7 B Clearances to Combustibles 8 C Calculating Alternate Floor Protection 10 D Locating Your Stove Chimney 11 E Chimney Termination Requirements 11 F 2 10 3 Rule 12 4 Chimney Systems A Venting Systems 13 B Inspections 13 C Larger Chimneys 13 D Masonry Chimney 13 E Metal Heat Circulating Masonry 15 F...

Page 3: ...be installed in a mobile home installation Improper installation adjustment alteration service or maintenance can cause injury or property damage For assistance or additional information consult a qualified installer service agency or your dealer Quadra Fire is a registered trademark of Hearth Home Technologies Installation and use of any damaged appliance Modification of the appliance Installatio...

Page 4: ...ation Installation MUST comply with local regional state and national codes and regulations Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits CAUTION WARNING Asphyxiation Risk DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM May...

Page 5: ...air handler joints and seams taped or sealed Basement installations should be avoided D Tools And Supplies Needed Before beginning the installation be sure the following tools and building supplies are available Reciprocating saw Framing material Pliers High temp caulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits Plumb line Safety gla...

Page 6: ...t requirements Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 7 Combustible materials not installed in non combustible areas Verified all clearances meet installation manual requirements Mantels and wall projections comply with installation manual requirements Protective hearth strips and hearth extension installed per manual requirements Appliance Set...

Page 7: ...13 7 16 in 342mm 18 11 16 in 475mm 22 1 16 in 560mm 3 1 16 in 78mm 6 5 8 in 168mm 15o 23 7 8 in 606mm Surround Sizes A B Standard 43 in 1092mm 31 in 787mm Large 51 in 1346mm 34 in 864mm 13 9 16 344mm 14 5 8 371mm 20 15 16 532mm 20 11 16 525mm 30 degree Vertical 30 o Figure 7 3 Side View With Optional 15 degree Adapter 3 Dimensions and Clearances A Appliance Dimensions NOTE Flue Collar size is 6 in...

Page 8: ...y authority having juris diction Fire Risk Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire WARNING SIDE TRIM SIDE WALL TOP TRIM 21 3 4 552mm 28 1 2 724mm HEARTH EXTENSION USA 16 3 4 CANADA 20 3 4 527mm 36 1 16 916mm FIREPLACE FRONT SURFACE USA 17 CANADA 19 483mm HEARTH EXTENSION 43 1 2 1105mm 12in max MANTEL See next page for thermal protectio...

Page 9: ... 3 With Adjustable Hearth Support Accessory Thermal Protection NOT Required Adj Hearth Support 0 to 3 1 2 inch 0 to 89mm USA ONLY Hearth Height 0 to 3 1 2 inch Full Reline Required 3 1 2 in 89mm Non Combustible Ember Protection Figure 9 2 With Adjustable Hearth Support Accessory USA and CANADA Build On Site Hearth Support Accessory Full Reline Required 3 1 2 in 89mm See Table Above 1 inch 25mm air...

Page 10: ...ial s resisteance to heat transfer R value is convenient when more than one material is used since you can add the R values together whereas you can not do this for k value The HIGHER the R factor means less heat is being conduct ed through the non combustible material to the combustible material beneath it The R value of a material must be equal or larger then the required R value to be acceptabl...

Page 11: ...ll through the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures ...

Page 12: ...Minimum 3 ft 91cm Minimum Wall or Parapet F 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimney connector as the flue collar on the unit Changing the diameter of the chimney can affect draft and cause poor performance It is not recommended to use offsets and elbows at altitudes above 4000 feet above sea...

Page 13: ...r cleaning and re installation When possible install an airtight clean out door to the rear of the smoke shelf A Venting Systems Chimney Connector It is also known as flue pipe or stove pipe It must be 6 inches 152mm minimum diameter stainless steel connector pipe Chimney The chimney can be new or existing masonry or prefabricated and must meet the following minimum requirements as specified below...

Page 14: ...cordance with Insert Listing Follow Manufacturer s Instructions for Maximum Liner Extension Above Chimney Maximum 30 Degrees Offset in Chimney Combustible Floor Masonry Chimney Cont d This insert conforms with the UL 1482 and ULC S628 Canada in all respects and is approved to UL ULC safety standards for installation and use within a fireplace with a masonry chimney in accordance with NFPA 211 and ...

Page 15: ...lue collar and the chimney top The air flow of the factory built zero clearance fireplace system must not be altered The flue liner top support attachment must not reduce the air flow for the existing air cooled chimney system No dilution air is allowed to enter the chimney 1 Secure the fireplace damper in the open position If this cannot be accomplished it will be necessary to remove the damper 2...

Page 16: ... fireplace opening the portion of the insert extending onto the hearth must be supported Manufacturer designed adjustable support kit can be ordered from your dealer Final approval of this installation type is contingent upon the authority having jurisdiction Fire Risk When lining air cooled factory built chimneys Run chimney liner approved to UL 1777 Type HT requirements 2100 degrees F Re install...

Page 17: ...rly Chimney heights exceeding 25 feet 7 62m from base of appliance may create an over draft situation Overdraft condition may create over firing Over firing may ignite creosote and or damage appliance and chimney WARNING A permit may be required for installations final approval is contingent of the authority having local jurisdiction Consult insurance carrier local building fire officials or autho...

Page 18: ... starvation WARNING Option One Installation Instructions The outside air cover comes packaged with the component pack It is necessary to remove the blower housing and block off the room air with the outside air cover 1 Remove the appliance cover plate on outer can and discard and reuse the 4 screws 2 Install optional flex adapter to outer can with the same screws Do not use plastic wire ties that ...

Page 19: ...here are 4 pre drilled holes in the flue collar 90 degrees apart Attach the flue collar to the stove pipe liner If the seal is questionable use high temperature sealant such as stove mastic Figure 19 1 2 Attach gasket to bottom side of flue collar with a thin coat of silicone C Leveling Legs 1 Remove the 2 screws already installed on each leg 2 Move legs to the desired height 3 Re install the scre...

Page 20: ...bly baffle board ceramic blanket and baffle protection channel E Surround Trim Kit Installation 1 Lay surround face down on a protected surface to pre vent scratching 2 Using a Phillips head screw driver attach the side sur rounds to the top surround using 2 8 sheet metal screws provided with the kit Figure 20 2 3 Lay the trim face down and place the corner brackets into position 4 Using a standar...

Page 21: ...iance Alignment Hole in Appliance Top Alignment Screw in Surround Top Surround Alignment Slot Alignment Pin on Appliance Start Up Air Control Figure 21 1 Figure 21 2 Figure 21 3 Surround Top Top F Top Installation Instructions NOTE The top is packaged separately and shipped with the appliance Install after the appliance is in place and the installation of the surround and trim are complete 1 Push ...

Page 22: ...th a Phillips head screw driver 5 Disconnect the spade terminals to the snap disc 6 Remove the blower control plate using a flat head screw driver to remove the 2 screws 1 on the top and 1 on the bottom Remove the blower control plate and wire har ness at the same time 7 On the left end of the blower housing remove the cover plate and re install on the right end of the housing 8 Install the blower...

Page 23: ...heet metal shears cut trim along the marked edge The cut edge fits under lip of top trim so it allows for some variance in your straight edge 5 The double sided tape that holds front and side trims to scissors has a particularly powerful bonding adhesive Adjustments are extremely difficult once trim has adhered to tape Do a dry run first without removing paper from tape 6 Place cut edge of trim un...

Page 24: ... from each side of insert and use plumbers tape to secure to structure a washer may be required Re install bolts 3 Unit must be grounded with 8 solid copper grounding wire or equivalent and terminated at each end with N E C approved grounding device 4 The factory built fireplace must meet UM 84 HUD requirements for outside combustion air supply to the fireplace fire chamber and the chimney must be...

Page 25: ...round Large SP 27IACC LRG Standard SP 27IACC STD Component Pack SRV7044 036 Outside Air Cover Plate SRV7046 182 U Clip Pkg of 4 7000 137 4 Surround Trim Assembly 43 X 31 Black TRIMKIT 4331 BK Gold Trim TRIMKIT 4331 GD Nickel Trim TRIMKIT 4331 NL Surround Trim Assembly 51 X 34 Black TRIMKIT 5134 BK Gold Trim TRIMKIT 5134 GD Nickel Trim TRIMKIT 5134 NL Bracket L Trim Pkg of 2 832 0840 ...

Page 26: ...26 7046 192C May 14 2015 2700 I ACC B Installation Notes ...

Page 27: ...May 14 2015 7046 192C 27 2700 I ACC ...

Page 28: ...mportant operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc tions for safe installa tion and operation DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This product...

Reviews: