background image

March 4, 2015

7033-308D

Page  15

3100 Series ACC Wood Burner

AUSTRALIAN WARRANTY INFORMATION

Hearth & Home Technologies Inc 

(

HHT

)

1445 N. Highway | Colville, WA 99114 | (509-684-3745)

HHT extends the following manufacturer’s warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased 
from an HHT authorized dealer.

HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance 
at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in 
materials and workmanship at the time of manufacture. 

After installation, if covered components manufactured by HHT are found to be defective in materials or workmanship during the applicable 
warranty period, HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of 
its obligations under this manufacturer’s warranty by replacing the product itself or refunding the veri

fi

 ed purchase price of the product 

itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to 
conditions, exclusions and limitations as described below.

Warranty coverage begins on the date of original purchase. In the case of new home construction, coverage under this manufacturer’s 
warranty begins on the date of 

fi

 rst occupancy of the dwelling or six months after the sale of the product by an independent, authorized 

HHT dealer/ distributor, whichever occurs earlier. The warranty period for this manufacturer’s warranty shall commence no later than 24 
months following the date of product shipment from HHT, regardless of the installation or occupancy date. The manufacturer’s warranty 
period for parts and labor for covered components is produced in the following table. 

The term “Limited Lifetime” in the table below is de

fi

 ned as: 20 years from the beginning date of warranty coverage for gas appliances, 

and 10 years from the beginning date of warranty coverage for wood, pellet and coal appliances. These time periods re

fl

 ect the minimum 

expected useful lives of the designated components under normal operating conditions.

Warranty Period

Hearth and Home Technologies Manufactured Appliances and Venting

Components Covered

Parts

Labor

Gas

Wood

Pellet

EPA

Wood

Coal

Electric

Venting

1 Year

X

X

X

X

X

X

X

All parts and material 
except as covered by 

Conditions, Exclusions, 

and Limitations listed

2 years

X

X

X

Igniters, electronic 

components, and glass

X

X

X

X

X

Factory-installed blowers

X

Molded refractory panels

3 years

X

Firepots and Burnpots

5 years

1 year

X

X

Castings and baf

fl

 es

7 years

3 years

X

X

X

Manifold tubes,

HHT chimney and 

termination

10 

years

1 year

X

Burners, logs and 

refractory

Limited 

Lifetime

3 years

X

X

X

X

X

Firebox and heat 

exchanger

90 Days

X

X

X

X

X

X

X

All replacement parts 

beyond warranty period

Summary of Contents for 31M-ACC-AU

Page 1: ...e systems as per AS NZS 2918 2001 Appendix F with a ceiling angle between 0 30 inclusive For installations with a ceiling angle greater than 30 refer to Fig 7 8 and AS NZS 2918 2001 4 6 3 b Ceiling Pl...

Page 2: ...fort of your hearth appliance Thank you for choosing Quadra Fire and Welcome to the Quadra Fire Family 3100 Series ACC JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2015 2016 2017 INSTALLATION DATE...

Page 3: ...re 3100 Millenium ACC Wood Burner Dimensions 616 mm 533 mm 254 mm 457 mm 273 mm 397 mm 379 mm 484 mm 749 mm 90 mm 25 mm 499 mm 406 mm 677 mm 46 mm Quadra Fire 3100 Limited Edition ACC Wood Burner Dime...

Page 4: ...are tested and comply with the minimum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 1 2 A Floor Protector can...

Page 5: ...m corner wall 756mm E Min floor protector front width 800mm F Min overall floor protector depth 1469mm CORNER POSITIONING 45 31M and 31LE Table 2 Fig 4 FIREBOX INSTALLATION 1 If a separate floor prote...

Page 6: ...308D March 4 2015 3100 Series ACC Wood Burner Quadra Fire 31 Step Top ACC Wood Burner Dimensions 678mm 618mm 391mm 292mm 406mm 527mm 870mm 635mm 318mm 237mm C L 457mm 606mm 841mm 194mm 537mm 264mm 170...

Page 7: ...and comply with the minimum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 3 4 A Floor Protector can include ce...

Page 8: ...om corner wall 661mm E Min floor protector front width 800mm F Min overall floor protector depth 1335mm CORNER POSITIONING 45 31 Step Top Table 4 Fig 6 FIREBOX INSTALLATION 1 If a separate floor prote...

Page 9: ...a phillips screwdriver to remove 4 screws on back Fig 14 1 3 Using a 11mm socket or wrench remove 4 wood lag bolts located in corners of pedestal base Fig 14 2 4 Lift stove off of pallet and reassemb...

Page 10: ...eptable Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition of metal L brackets affix to the outer casing...

Page 11: ...combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing Roof Line Inner Casing 200mm above roof line Outer Casing Inner Ca...

Page 12: ...ownward distance of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing A Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe Fig 7 ADD Cowl AS...

Page 13: ...entral tongue to locate inside the flue outlet only Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will mount lower onto the appliance The Flue Mounted Shi...

Page 14: ...ION IS CONSIDERED THE MAN UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MO...

Page 15: ...under this manufacturer s warranty begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occu...

Page 16: ...otes DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instr...

Reviews: