background image

Page  8

7033-308D

March 4, 2015

3100 Series ACC Wood Burner

CORNER POSITIONING (45°)

DESCRIPTION

Pioneer Double Flue Mounted Shield Universal

Shall be Fitted

With Double 

Flue Shield 

Fitted

A

Min. clearance from 

fi

 rebox corner to corner walls

130mm

B

Min. distance from center of spigot to corner walls

437mm

C

Min. distance from corner wall to 

fl

 oor protector front

1227mm

D

Min. 

fl

 oor protector projection from corner wall

661mm

E

Min. 

fl

 oor protector front width 

800mm

F

Min. overall 

fl

 oor protector depth

1335mm

CORNER POSITIONING (45°) - 31 Step Top

Table 4

Fig. 6

FIREBOX INSTALLATION

1.  If a separate 

fl

 oor protector is being used position now. Place the 

fi

 rebox on the 

fl

 oor protector to 

suit the minimum installation clearances. (See Fig 5 or 6).
2.  Seismically restrain the 

fi

 rebox and the 

fl

 oor protector to the 

fl

 oor.

3.  Fit 2 x 6mm 

fi

 xings suitable for the 

fl

 oor material. DO NOT over tighten.

4.  Fit timber trim pedestal edging to front and back of base (optional).

A

B

D

E

F

C

FLOOR PROTECTOR

CORNER W

ALL

CORNER W

ALL

Summary of Contents for 31M-ACC-AU

Page 1: ...e systems as per AS NZS 2918 2001 Appendix F with a ceiling angle between 0 30 inclusive For installations with a ceiling angle greater than 30 refer to Fig 7 8 and AS NZS 2918 2001 4 6 3 b Ceiling Pl...

Page 2: ...fort of your hearth appliance Thank you for choosing Quadra Fire and Welcome to the Quadra Fire Family 3100 Series ACC JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2015 2016 2017 INSTALLATION DATE...

Page 3: ...re 3100 Millenium ACC Wood Burner Dimensions 616 mm 533 mm 254 mm 457 mm 273 mm 397 mm 379 mm 484 mm 749 mm 90 mm 25 mm 499 mm 406 mm 677 mm 46 mm Quadra Fire 3100 Limited Edition ACC Wood Burner Dime...

Page 4: ...are tested and comply with the minimum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 1 2 A Floor Protector can...

Page 5: ...m corner wall 756mm E Min floor protector front width 800mm F Min overall floor protector depth 1469mm CORNER POSITIONING 45 31M and 31LE Table 2 Fig 4 FIREBOX INSTALLATION 1 If a separate floor prote...

Page 6: ...308D March 4 2015 3100 Series ACC Wood Burner Quadra Fire 31 Step Top ACC Wood Burner Dimensions 678mm 618mm 391mm 292mm 406mm 527mm 870mm 635mm 318mm 237mm C L 457mm 606mm 841mm 194mm 537mm 264mm 170...

Page 7: ...and comply with the minimum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 3 4 A Floor Protector can include ce...

Page 8: ...om corner wall 661mm E Min floor protector front width 800mm F Min overall floor protector depth 1335mm CORNER POSITIONING 45 31 Step Top Table 4 Fig 6 FIREBOX INSTALLATION 1 If a separate floor prote...

Page 9: ...a phillips screwdriver to remove 4 screws on back Fig 14 1 3 Using a 11mm socket or wrench remove 4 wood lag bolts located in corners of pedestal base Fig 14 2 4 Lift stove off of pallet and reassemb...

Page 10: ...eptable Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition of metal L brackets affix to the outer casing...

Page 11: ...combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing Roof Line Inner Casing 200mm above roof line Outer Casing Inner Ca...

Page 12: ...ownward distance of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing A Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe Fig 7 ADD Cowl AS...

Page 13: ...entral tongue to locate inside the flue outlet only Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will mount lower onto the appliance The Flue Mounted Shi...

Page 14: ...ION IS CONSIDERED THE MAN UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MO...

Page 15: ...under this manufacturer s warranty begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occu...

Page 16: ...otes DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instr...

Reviews: