January 17, 2013
7033-308B
Page 5
R
3100 Series ACC Wood Burner
CORNER POSITIONING (45°)
DESCRIPTION
Pioneer Double Flue Mounted Shield Universal
Shall be Fitted
With Double
Flue Shield
Fitted
A
Min. clearance from firebox corner to corner walls
225
B
Min. distance from center of spigot to corner walls
532
C
Min. distance from corner wall to floor protector front
1322
D
Min. floor protector projection from corner wall
756
E
Min. floor protector front width
800
F
Min. overall floor protector depth
1469
CORNER POSITIONING (45°)
Table 2
Fig. 4
FIREBOX INSTALLATION
1. If a separate floor protector is being used position now. Place the firebox on the floor protector to
suit the minimum installation clearances. (See Fig 3 or 4).
2. Seismically restrain the firebox and the floor protector to the floor.
3. Fit 2 x 6mm fixings suitable for the floor material. DO NOT over tighten.
4. Fit timber trim pedestal edging to front and back of base (optional).
A
B
D
E
F
C
FLOOR PROTECTOR
CORNER
WALL
CORNER
WALL