Page 14
7037-135H
December 16, 2011
R
4300 Wood Stove Series (ACC)
B. Outside Air Kit Installation
1. Remove all materials from packing box.
2. Using a #2 Phillips screw driver attach the flex adapter
to the stove using 4 screws.
Figure 14.1.
3. For floor installations remove circular” knock-out” in the
base of the pedestal.
4
.
Floor & Rear Installation:
Cut a 4 inch (102mm)
hole in outside wall or floor to accommodate outside
air piping. Use 4 inch (102mm) aluminum metal flex or
rigid piping to directly connect outside air to appliance
intake. Use the supplied termination cap with a rodent
screen. Seal between the wall (or floor) and the pipe
with silicone to prevent moisture penetration.
Items Needed for Installation (not supplied)
• 4 inch flex aluminum pipe, or if using alternate material,
then it shall be made from durable, non-combustible,
heat resistant material up to 350
o
F. Cut the pipe to
the required length for your installation.
• Phillips head screw driver
• Silicone sealant
• Drills and saws necessary for cutting holes through
the wall or flooring in your home.
Figure 14.1 - Floor & Rear Installation
A source of air (oxygen) is necessary in order for combus
-
tion to take place. Whatever combustion air is consumed
by the fire must be replaced. Air is replaced via air leak
-
age around windows and under doors. In homes that have
tightly sealed doors and windows, an outside air source is
needed. An optional Outside Air Kit is available.
Flex Line
Wire Tie
Wire Tie
Flex Adapter
Termination
Cap
For Floor Installa-
tions Remove
Circular “Knock-Out”
in Base of Pedestal.
WARNING
Do not draw outside combustion air from:
• Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
• Close proximity to exhaust vents or
chimneys
Fumes or odor may result
Fire Risk.
Asphyxiation Risk.
Asphyxiation Risk.
Outside air inlet must be located to prevent block
-
age from:
• Leaves
• Snow or ice
• Other debris
Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensi
-
tive individuals.
WARNING
Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed
the length of the vertical height of the exhaust flue.
•
Fire will not burn properly
•
Smoke spillage occurs when door is opened due
to air starvation.
WARNING
Included in OAK-ACC:
Termination cap, (2) wire ties, flex
adapter, and fasteners
Included in SRV7033-041
:
Cover plate and sealing rope (see
Floor Installation Alternative below,
Figure 14.2
)
Figure 14.2 - Floor Installation Alternative
Cover
Plate
Rope to Seal
Pedestal
5.
Floor Installation Alternative:
In some instances you may
not be able to install the flex pipe as show in
Figure 14.1.
If that is the case, you will need to order SRV7033-041
which includes a cover plate and sealing rope as shown in
Figure 14.2.
The goal is to seal the pedestal so no room
air can leak into the pedestal or cold air infiltration.