2
7037-171E
August
13,
2018
4300 Wood Stove Series ACC
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
PART NAME:
DRAWN BY:
SCALE:
MATERIAL:
SHEET:
PART NUMBER:
REV:
THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING
DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.
ECO #
DATE
BY
REV
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03 (3) PLACE DEC: ± 0.005 ANGLE: ± 2° FRACTION: ± 1/16
OUTSIDE MATERIAL.
NORMAL DIM & INSIDE MATERIAL.
OUTSIDE APEX
INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
REVISIONS
ITEM
PART NUMBER
PART NAME
QTY
11
UPDATE TO REFLECT HALIFAX CHANGES
84782
03/21/17
TPS
LABEL
XXX
NTS
SEE NOTE
1 OF 1
7037-136
11
RELEASED
NOTE:
1. MATERIAL: NON-ANODIZED ALUMINUM 0.020 THICK
2. BACKGROUND: SILVER
3. COPY: BLACK & RED
4. ADHESIVE: 3M #468 PERMANENT ACRYLIC
5. TEMPERATURE RATING: -50 F TO 350 F
H UPDATED ALL NOTE MATERIAL; UPDATED MFG YEARS
75223
5/20/14
WPK
I 2015 NSPS UPDATE
77523
05/04/15
BLW
J
UPDATED INSTALL: ALCOVE & SN TO NEW STANDARD
82646
10/03/16
IJW
1
7037-136
SERIAL RATING PLATE
1
INSTALLATION: FULL VERTICAL OR HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP
INSTALLATION: ENTIÈREMENT VERTICALE OU HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
SINGLE WALL PIPE
A B C D E F G H
Flat Top Model
15.5 (394) 11.75 (298) 24.5 (622) 14.5 (368) 10 (255) 17.5 (445) 53.5 (1359) 12 (305)
Step Top Model
15.5 (394) 11.75 (298) 24.5 (584) 14.5 (368) 2 (51) 12 (305) 49.5 (1283) 12 (305)
DOUBLE WALL PIPE
Flat Top Model
9 (229) 5.25 (133) 24.5 (622) 14.5 (368) 10 (255) 17.5 (445) 53.5 (1359) 12 (305)
Step Top Model
7.5 (191) 3.75 (95) 22 (559) 11.75 (298) 2 (51) 12 (305) 49.5 (1283) 5 (127)
INSTALLATION: 90o ELBOW OFF TOP OF STOVE THROUGH BACKWALL
INSTALLATION: 90o DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIÈRE
DOUBLE WALL PIPE
Flat Top Model
8.5 (216) 6 (152) 24.5 (622) 15 (381) 10 (254) 17.5 (445) 53.5 (1359)
N/A
Step Top Model
7.5 (191) 4 (102) 19 (229) 9 (229) 2 (51) 12 (305) 49.5 (1283)
N/A
I
NSTALLATION: ALCOVE
-
Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT** listed factory-built Class "A"
chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1219mm)
and the referenced alcove clearances
.
INSTALLATION: ALCÔVE -
Six pouces (6 pouces) (152mm) de diamètre listé air isolé tuyau de raccordement à double paroi avec UL103 HT ** cotée Classe usine construite "A"
cheminée ou une cheminée de maçonnerie. (Mobile Home doit être équipé d' un pare-étincelles.) Profondeur maximale de Alcove ne doit pas être plus de 48 pouces (1219mm) et les
dégagements en alcôve référencés.
DOUBLE WALL PIPE
Flat Top Model
13 (330) 10 (255) 24 (610) 14.5 (368) N/A
N/A
53.5 (1359) 12 (305)
Step Top Model
7.5
(191) 3.75 (95) 22 (584) 11.75 (298) N/A
N/A
49.5 (1257) 5 (127)
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650oC Factory-built chimney.
*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650oC cheminée bâtit en usine.
SPÉCIFICATIONS DE LA VENTILATION:
MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de minimum
d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine UL103HT* de
Classe "A", adéquate pour usage avec les combustions solides, ou une cheminée de briques,
avec espaces libres référés.
MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé pour
mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou une cheminée de
briques, avec espaces libres alloués.
MAISON MOBILE: Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk Metalbestos DS
ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les espaces libres pour mur double
comme mentionné ci-bas.
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:En Pouces & (millimètres)
NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de l'entrée du conduit.
LISTED ROOM HEATER, SOLID FUEL TYPE.
ALSO FOR USE IN MOBILE HOMES. (UM) 84 HUD
352 Mountain House Road, Halifax, PA 17032
www.quadrafire.com
In
stall and use only in accordance with
manufacturer's installation and operating instructions.
Contact local building or fire officials about restrictions
and installation inspections in your area. Do not
obstruct the space beneath heater.
For use only with leg and pedestal options intended
for this model, refer to owner’s manual for appropriate
part numbers and installation instructions.
WARNING - For Mobile Home
s: Do not install in a
sleeping room. An outside combustion air inlet must be
provided and unrestricted while unit is in use. The
structural integrity of the mobile home floor, ceiling and
walls must be maintained. The stove needs to be
properly grounded to the frame of the mobile home.
Components required for mobile home installation:
Outside Air Kit, Part Number OAK-ACC.
Refer to manufacturer's instructions
and local
codes for precautions required for passing chimney
through a combustible wall or ceiling and maximum
offsets.
Inspect and clean chimney frequently - Under Certain
Conditions of Use, Creosote Buildup May Occur
Rapidly.
Do not connect this unit to a chimney serving another appliance.
Optional Components: Optional Blower, Part
812-4900.
Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.
Route power cord away from unit. Do not route cord
under or in front of appliance.
DANGER: Risk of electrical shock
. Disconnect
power supply before servicing.
Replace glass only with 5mm ceramic available from
your dealer.
Do not use grate or elevate fire. Build wood fire
directly on hearth.
Do not overfire - if heater or chimney connector glows,
you are overfiring.
Operate only with the fuel loading door closed. Open
only to add fuel to the fire.
CAUTION
:
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply
with 2015 particulate emission standards at 1.1 g/hr EPA Method 28
and 5G. Not approved for sale after May 15, 2020.
2017 2018 2019 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.
PREVENT HOUSE FIRES
EMBER PROTECTION
:
It is necessary to install a Type I floor protector.
Floor protector must be non-combustible material,
extending beneath appliance and to front/sides/rear as
indicated on the diagram below.
Exception
:
Non-combustible floor protections must extend beneath the
flue pipe when installed with horizontal venting and extend
2 inches (51mm) beyond each side.
Report / Rapport
0061WS067S
TESTED TO:/ TESTÉ À:
UL 1482-11 (R2015), ULC S627-00.
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS.
VENT SPECIFICATIONS:
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or blued steel connector
pipe, with a listed factory-built UL103HT* Class "A" chimney, suitable for use with solid fuels, or a
masonry chimney, and the referenced clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air insulated connector pipe
with listed factory-built UL103HT* Class "A" chimney, or a masonry chimney and the referenced
clearances
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double
wall connector pipe. Must be equipped with a spark arrestor. Apply double wall clearances below when
installing unit.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE: All "A" , T"C" and "F" Dimensions are to inside diameter of the flue collar.
R
7037-136_R11
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES
BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.
ATTENTION:
APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES
MAISONS MOBILES. (UM) 84 HUD.
"Pour Usage
Avec Bois Solide Seulement"
I
nstallez et utilisez en accord avec les instructions
d'installation et d'opération du fabricant. Contactez le bureau
de la construction ou le bureau des incendies au sujet des
restrictions et des inspections d'installation dans votre
voisinage. Ne pas obstruez l'espace en dessous de
l'appareil.
AVIS - Pour Les Maisons Mobiles:
Ne pas installer dans
une chambre à coucher. Un tuyau extérieur de combustion
d'air doit être installé et ne doit pas être obstrué lorsque
l'appareil est en usage. La structure intégrale du plancher, du
plafond et des murs de la maison mobile doit être maintenue
intacte. L'appareil de chauffage doit être fixé à la charpente
de la maison mobile. Les composants requis pour
l'installation des maisons mobiles: Assemblage d'air
extérieur, Numéro de Pièce OAK-ACC.
Référez vous aux instructions du fabricant
et des codes
locaux pour les précautions requises pour passer une cheminée
à travers un mur ou un plafond combustibles, et les
compensations maximums.
Inspectez et nettoyez la cheminée fréquemment. Sous
certaines conditions, il se peut que la créosote s'accumule
rapidement.
Ne pas connecter cet appareil à une cheminée servant un
autre appareil.
Composants Optionnels: Ventilateur Optionnel, Pièce
812-4900.
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
Éloignez le fil électrique de l'appareil. Ne pas faire passer le
fil électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique
.
Déconnectez le fil électrique de la prise de contact avant le
service.
Remplacez la vitre seulement avec une vitre céramique de 5
mm disponible chez votre fournisseur.
N'élevez pas le feu. Bâtissez le feu de bois directement sur
l'âtre.
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau de
cheminée rougissent, vous surchauffez.
Opérez l'appareil seulement lorsque la porte de chargement
est fermée. Ouvrez la porte seulement lorsque vous devez
ajouter des combustibles dans le feu.
PRÉVENTION DES FEUX DE MAISON
PROTECTION DU PLANCHER:
Le protecteur de plancher doit être d'un minimum de 3/8
inch (10mm) d'épaisseur de matériel incombustible ou
équivalent, s'étendant du dessous de l'appareil de
chauffage à l'avant, aux cotés et à l'arrière comme indiqué
sur le diagramme suivant. Exception: Les protections
incombustibles du plancher doivent s'étendre en dessous
du conduit de cheminée lorsqu'installées avec une
ventilation à l'horizontale et s'étendre de 2 inches (51mm)
de chaque côté.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Manufactured by:
Fabriqué par:
G
A
B
ALCOVE TOP VIEW /
VUE DU HAUT DE L'ALCÔVE
C
D
BACKWALL/SIDEWALL
MUR ARRIÈRE/MUR DE CÔTÉ
A
B
C
D
90
o
OFF TOP
UP & OUT CEILING CLEARANCE
ESPACE LIBRE DU DESSUS DE
L'APPAREIL AU PLAFOND AVEC 90
DE COURBURE
STOVE TO CEILING CLEARANCE
ESPACE LIBRE DU POÊLE AU
PLAFOND
G
G
H
CORNER INSTALLATION/
INSTALLATION DU COIN
E
F
E
F
G
H
ALCOVE SIDE VIEW /
VUE DE CÔTÉ DE L'ALCÔVE
G
A
B
16" from glass
8"
USA
Fuel loading door
4-3/4"
3-1/4"
31-5/8" minimum
41"
minimum
CANADA
203mm (8")
203mm
(8")
203mm
(8")
457mm (18")
1295mm
(51")
minimum
1066mm (42") minimum
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
Flat Top & Step Top
Flat Top & Step Top
Made in U.S.A. of US and
imported parts.
Fabriqué aux
États-Unis-d’Amérique par des
pièces d’origine américaine et
pièces importées.
This wood heater needs periodic inspection and repair for proper operation.
Consult the owner’s manual for further information. It is against federal regulations
to operate this wood heater in a manner inconsistent with the operating instructions
in the owner’s manual.
43 MILLENIUM
43 STEP TOP
DISCOVERY III
Serial No. / N° de série
HF
BARCODE LABEL
CONDUIT DU MUR DOUBLE
Modèle au dessus en appartement
Modèle au dessus en escalier
CONDUIT DU MUR DOUBLE
Modèle au dessus en appartement
Modèle au dessus en escalier
CONDUIT DU MUR DOUBLE
Modèle au dessus en appartement
Modèle au dessus en escalier
CONDUIT DU MUR DOUBLE
Modèle au dessus en appartement
Modèle au dessus en escalier
4300 ACC Series
Serial No.
Model
Name
Test Lab &
Report No.
Mfg. Date
A. Sample of Serial Number / Safety Label
LOCATION: Back of appliance
NOTE: Clearances may only be reduced by means approved
by the regulatory authority having jurisdiction