background image

 

      7037-171E 

   

August 

13, 

2018

4300 Wood Stove Series ACC

CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.

PART NAME:

DRAWN BY:

SCALE:

MATERIAL:

SHEET:

PART NUMBER:

REV:

THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING 

DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.

ECO #

DATE

BY

REV

UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE:  (2) PLACE DEC : ± 0.03     (3) PLACE DEC: ± 0.005     ANGLE: ± 2°     FRACTION: ± 1/16

OUTSIDE MATERIAL.

NORMAL DIM & INSIDE MATERIAL.

OUTSIDE APEX

INSIDE APEX  -  DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS

REVISIONS

ITEM

PART NUMBER

PART NAME

QTY

11

UPDATE TO REFLECT HALIFAX CHANGES

84782

03/21/17

TPS

LABEL

XXX

NTS

SEE NOTE

1 OF 1

7037-136

11

RELEASED

NOTE:

1. MATERIAL: NON-ANODIZED ALUMINUM 0.020 THICK

2. BACKGROUND: SILVER

3. COPY: BLACK & RED

4. ADHESIVE:  3M #468 PERMANENT ACRYLIC

5. TEMPERATURE RATING: -50 F TO 350 F

H UPDATED ALL NOTE MATERIAL; UPDATED MFG YEARS

75223

5/20/14

WPK

I 2015 NSPS UPDATE

77523

05/04/15

BLW

J

UPDATED INSTALL: ALCOVE & SN TO NEW STANDARD

82646

10/03/16

IJW

1

7037-136

SERIAL RATING PLATE

1

INSTALLATION: FULL VERTICAL OR HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP

INSTALLATION: ENTIÈREMENT VERTICALE OU HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE

SINGLE WALL PIPE

 

A  B  C  D E  F  G  H

Flat Top Model

 

15.5 (394)  11.75 (298)  24.5 (622)  14.5 (368)  10 (255)  17.5 (445)   53.5 (1359)  12 (305)

Step Top Model

 

15.5 (394)  11.75 (298)  24.5 (584)  14.5 (368)  2 (51)  12 (305)  49.5 (1283)  12 (305)

DOUBLE WALL PIPE

 Flat Top Model

 

9 (229)  5.25 (133)  24.5 (622)  14.5 (368)  10 (255)  17.5 (445)  53.5 (1359)  12 (305)

Step Top Model

 

7.5 (191)  3.75 (95)  22 (559)  11.75 (298)  2 (51)  12 (305)  49.5 (1283)  5 (127)

INSTALLATION:  90o ELBOW OFF TOP OF STOVE THROUGH BACKWALL

INSTALLATION:  90o DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIÈRE

DOUBLE WALL PIPE

 Flat Top Model

 

8.5 (216)  6 (152)  24.5 (622)  15 (381)  10 (254)  17.5 (445)  53.5 (1359) 

N/A

 Step Top Model

 

7.5 (191)  4 (102)  19 (229)  9 (229)  2 (51)  12 (305)  49.5 (1283) 

N/A

I

NSTALLATION:   ALCOVE 

-

Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT** listed factory-built Class "A" 

chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1219mm) 

and the referenced alcove clearances

.

INSTALLATION: ALCÔVE - 

Six pouces (6 pouces) (152mm) de diamètre listé air isolé tuyau de raccordement à double paroi avec UL103 HT ** cotée Classe usine construite "A" 

cheminée ou une cheminée de maçonnerie. (Mobile Home doit être équipé d' un pare-étincelles.) Profondeur maximale de Alcove ne doit pas être plus de 48 pouces (1219mm) et les 

dégagements en alcôve référencés.

DOUBLE WALL PIPE

Flat Top Model

 

 13 (330)     10 (255)  24 (610)  14.5 (368)  N/A 

N/A 

53.5 (1359)  12 (305)

 Step Top Model 

7.5

 (191)  3.75 (95)  22 (584)  11.75 (298)  N/A 

N/A 

49.5 (1257)  5 (127)

*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650oC Factory-built chimney.

*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650oC cheminée bâtit en usine.

SPÉCIFICATIONS DE LA VENTILATION:

MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de minimum 

d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine UL103HT* de 

Classe "A", adéquate pour usage avec les combustions solides, ou une cheminée de briques, 

avec espaces libres référés.

MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé pour 

mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou une cheminée de 

briques, avec espaces libres alloués.

MAISON MOBILE:  Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk Metalbestos DS 

ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les espaces libres pour mur double 

comme mentionné ci-bas.

ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:En Pouces & (millimètres)

NOTE:  Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de l'entrée du conduit.

LISTED ROOM HEATER, SOLID FUEL TYPE.   

ALSO FOR USE IN MOBILE HOMES. (UM) 84 HUD

352 Mountain House Road, Halifax, PA 17032 

www.quadrafire.com

In

stall and use only in accordance with 

manufacturer's installation and operating instructions.  

Contact local building or fire officials about restrictions 

and installation inspections in your area. Do not 

obstruct the space beneath heater. 

For use only with leg and pedestal options intended 

for this model, refer to owner’s manual for appropriate 

part numbers and installation instructions.

WARNING - For Mobile Home

s:  Do not install in a 

sleeping room.  An outside combustion air inlet must be 

provided and unrestricted while unit is in use.  The 

structural integrity of the mobile home floor, ceiling and 

walls must be maintained.  The stove needs to be 

properly grounded to the frame of the mobile home.  

Components required for mobile home installation:  

Outside Air Kit, Part Number OAK-ACC.

Refer to manufacturer's instructions 

and local 

codes for precautions required for passing chimney 

through a combustible wall or ceiling and maximum 

offsets.

Inspect and clean chimney frequently - Under Certain 

Conditions of Use, Creosote Buildup May Occur 

Rapidly.

Do not connect this unit to a chimney serving another appliance.

Optional Components:  Optional Blower, Part 

812-4900.

Electrical Rating:  115 VAC, 1.2 Amps, 60 Hz.

Route power cord away from unit.  Do not route cord 

under or in front of appliance.

DANGER: Risk of electrical shock

.  Disconnect 

power supply before servicing.

Replace glass only with 5mm ceramic available from 

your dealer.

Do not use grate or elevate fire.  Build wood fire 

directly on hearth.

Do not overfire - if heater or chimney connector glows, 

you are overfiring.

Operate only with the fuel loading door closed.  Open 

only to add fuel to the fire.

CAUTION

:

U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply 

with 2015 particulate emission standards at 1.1 g/hr EPA Method 28 

and 5G. Not approved for sale after May 15, 2020.

2017  2018  2019  Jan.  Feb.  Mar.  Apr.  May  June July  Aug. Sept. Oct.  Nov.  Dec.

PREVENT HOUSE FIRES

EMBER PROTECTION

:

It is necessary to install a Type I floor protector.

Floor protector must be non-combustible material, 

extending beneath appliance and to front/sides/rear as 

indicated on the diagram below. 

Exception

:

Non-combustible floor protections must extend beneath the 

flue pipe when installed with horizontal venting and extend 

2 inches (51mm) beyond each side.

Report / Rapport

0061WS067S

TESTED TO:/ TESTÉ À:

   UL 1482-11 (R2015),  ULC S627-00. 

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS.  KEEP FURNISHINGS AND OTHER

COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS.

VENT SPECIFICATIONS:

SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or blued steel connector 

pipe, with a listed factory-built UL103HT* Class "A" chimney, suitable for use with solid fuels, or a 

masonry chimney, and the referenced clearances.

DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air insulated connector pipe 

with listed factory-built UL103HT* Class "A" chimney, or  a masonry chimney and the referenced 

clearances

MOBILE HOME:  Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double 

wall connector pipe. Must be equipped with a spark arrestor.  Apply double wall clearances below when 

installing unit.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)

NOTE:  All "A" , T"C" and "F" Dimensions are to inside diameter of the flue collar.

R

7037-136_R11

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES 

BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.

ATTENTION:

APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE 

COMBUSTIBLE SOLIDE, POUR USAGE DANS LES 

MAISONS MOBILES. (UM) 84 HUD. 

"Pour Usage 

Avec Bois Solide Seulement"

I

nstallez et utilisez en accord avec les instructions 

d'installation et d'opération du fabricant. Contactez le bureau 

de la construction ou le bureau des incendies au sujet des 

restrictions et des inspections d'installation dans votre 

voisinage. Ne pas obstruez l'espace en dessous de 

l'appareil.

AVIS - Pour Les Maisons Mobiles:

  Ne pas installer dans 

une chambre à coucher. Un tuyau extérieur de combustion 

d'air doit être installé et ne doit pas être obstrué lorsque 

l'appareil est en usage. La structure intégrale du plancher, du 

plafond et des murs de la maison mobile doit être maintenue 

intacte. L'appareil de chauffage doit être fixé à la charpente 

de la maison mobile. Les composants requis pour 

l'installation des maisons mobiles: Assemblage d'air 

extérieur, Numéro de Pièce OAK-ACC.

Référez vous aux instructions du fabricant 

et des codes 

locaux pour les précautions requises pour passer une cheminée 

à travers un mur ou un plafond combustibles, et les 

compensations maximums.

Inspectez et nettoyez la cheminée fréquemment. Sous 

certaines conditions, il se peut que la créosote s'accumule 

rapidement.

Ne pas connecter cet appareil à une cheminée servant un 

autre appareil.

Composants Optionnels: Ventilateur Optionnel, Pièce 

812-4900.

Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.

Éloignez le fil électrique de l'appareil. Ne pas faire passer le 

fil électrique au dessus ou en dessous de l'appareil.

DANGER: Il y a risque de décharge électrique

.

Déconnectez le fil électrique de la prise de contact avant le 

service.

Remplacez la vitre seulement avec une vitre céramique de 5 

mm disponible chez votre fournisseur.

N'élevez pas le feu. Bâtissez le feu de bois directement sur 

l'âtre.

Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau de 

cheminée rougissent, vous surchauffez.

Opérez l'appareil seulement lorsque la porte de chargement 

est fermée. Ouvrez la porte seulement lorsque vous devez 

ajouter des combustibles dans le feu.

PRÉVENTION DES FEUX DE MAISON

PROTECTION DU PLANCHER:

Le protecteur de plancher doit être d'un minimum de 3/8 

inch (10mm) d'épaisseur de matériel incombustible ou 

équivalent, s'étendant du dessous de l'appareil de 

chauffage à l'avant, aux cotés et à l'arrière comme indiqué 

sur le diagramme suivant. Exception: Les protections 

incombustibles du plancher doivent s'étendre en dessous 

du conduit de cheminée lorsqu'installées avec une 

ventilation à l'horizontale et s'étendre de 2 inches (51mm) 

de chaque côté.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Manufactured by:
Fabriqué par:

G

A

B

ALCOVE TOP VIEW /

VUE DU HAUT DE L'ALCÔVE 

C

D

BACKWALL/SIDEWALL

MUR ARRIÈRE/MUR DE CÔTÉ 

A

B

C

D

90

o

 OFF TOP 

UP & OUT CEILING CLEARANCE
ESPACE LIBRE DU DESSUS DE 

L'APPAREIL AU PLAFOND AVEC 90 

DE COURBURE 

STOVE TO CEILING CLEARANCE
ESPACE LIBRE DU POÊLE AU 

PLAFOND

G

G

H

CORNER INSTALLATION/

INSTALLATION DU COIN 

E

F

E

F

G

H

ALCOVE SIDE VIEW / 

VUE DE CÔTÉ DE L'ALCÔVE

G

A

B

16" from glass

8"

USA

Fuel loading door

4-3/4"

3-1/4"

31-5/8" minimum

41"

minimum

CANADA

203mm (8")

203mm

(8")

203mm

(8")

457mm (18")

1295mm

(51")

minimum

1066mm (42") minimum

O-T L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

Flat Top & Step Top

Flat Top & Step Top

Made in U.S.A. of US and 

imported parts.

Fabriqué aux 

États-Unis-d’Amérique par des 

pièces d’origine américaine et 

pièces importées.

This wood heater needs periodic inspection and repair for proper operation. 

Consult the owner’s manual for further information. It is against federal regulations 

to operate this wood heater in a manner inconsistent with the operating instructions 

in the owner’s manual.

43 MILLENIUM

43 STEP TOP

DISCOVERY III

Serial No. / N° de série

HF

BARCODE LABEL

CONDUIT DU MUR DOUBLE

Modèle au dessus en appartement

Modèle au dessus en escalier

CONDUIT DU MUR DOUBLE

Modèle au dessus en appartement

Modèle au dessus en escalier

CONDUIT DU MUR DOUBLE

Modèle au dessus en appartement

Modèle au dessus en escalier

CONDUIT DU MUR DOUBLE

Modèle au dessus en appartement

Modèle au dessus en escalier

4300 ACC Series

Serial No.
Model 

Name
Test Lab & 

Report No.

Mfg. Date

A. Sample of Serial Number / Safety Label 

LOCATION:  Back of appliance

NOTE: Clearances may only be reduced by means approved 

by the regulatory authority having jurisdiction

Summary of Contents for 43ST-ACC-B

Page 1: ...ay over fire and generate poisonous gases i e carbon monoxide WARNING If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over ...

Page 2: ...front sides rear as indicated on the diagram below Exception Non combustible floor protections must extend beneath the flue pipe when installed with horizontal venting and extend 2 inches 51mm beyond each side Report Rapport 0061WS067S TESTED TO TESTÉ À UL 1482 11 R2015 ULC S627 00 HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDRENAND CLOTHINGAWAY CONTACT MAY CAUSE SKIN BURNS KEEP FURNISHINGSAND OT...

Page 3: ...ance and Service A Quick Reference Maintenance Guide 18 B Cleaning and Operating the Ash Removal System 19 C General Maintenance 19 4 Troubleshooting Guide 5 Service Part Replacement A Glass Replacement Door Assembly 22 B Firebrick Replacement 22 C Snap Disc Replacement 22 D Door Handle Assembly 23 E Baffle Removal 23 F Tube Channel Assembly Replacement 24 6 Reference Materials A Service Maintenan...

Page 4: ...nents and glass X X X Factory installed blowers X Molded refractory panels X Ignition Modules X Firepots burnpots mechanical feeders auger assemblies X Vent Free burners Vent Free ceramic fiber logs Aluminized Burners X X Castings and Baffles 6 years 3 years X Catalyst limitations listed 7 years 3 years X X Manifold tubes HHT chimney and termination 10 years 1 year X Burners logs and refractory Li...

Page 5: ...en arranging a warranty call Travel and shipping charges for parts are not covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period as follows if the original o From 37 to 72 months a pro rated credit will be allowed against a replacement catalyst and labor credit necessary to install Amount of Time Si...

Page 6: ...s due to water or weather damage which is the result of but not limited LIMITATIONS OF LIABILITY have other rights which vary from state to state EXCEPT TO THE EXTENT PROVIDED BY LAW HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE ...

Page 7: ...tarted and after refueling to prevent Spillage of smoke flame and carbon monoxide Spillage of sparks coals and logs Over firing DO NOT leave the appliance unattended with the door open Starting a fire may not require an open door for draft The air control should supply adequate draft ADD MORE WOOD REDUCE AIR CONTROLS Ser to desired heat output The appliance is ready for normal operation HIGH BURN ...

Page 8: ... BTU Output 11 800 to 38 300 hr Peak BTU Hour Output 63 700 Vent Size 6 inches Firebox Size 2 30 cubic feet Recommended Wood Length 18 inches Fuel Orientation Front to Back Fuel Seasoned Cord Wood Weighted average LHV Low Heating Value efficiency using Douglas Fir dimensional lumber and data collected during EPA emission test Weighted average HHV High Heating Value efficiency using Douglas Fir dim...

Page 9: ...and walls must be maintained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter liner must be used Outside Air Kit part OAK ACC must be installed in a mobile home installation Improper installation adjustment alteration service or maintenance can cause injur...

Page 10: ...ections from the center it is dry If your wood sizzles in the fire even though the surface is dry it may not be fully cured Splitting wood before it is stored reduces drying time Wood should be stacked so that both ends of each piece are exposed to air since more drying occurs through the cut ends than the sides This is true even with wood that has been split Store wood under cover such as in a sh...

Page 11: ...2 HIGH MED LOW Burn Rate Air Control Start Up Air Control Manual Timer ACC Shut Down Pull Forward to Shut Down Injury Risk Gloves recommended CAUTION D Air Controls Users will need to find their preferred setting between high and low based on desired heat output installation configuration and fuel type 1 Burn Rate Air Control This air supply enters at the upper front of the firebox near the top of...

Page 12: ...ystem by pushing the knob all the back toward the appliance to HI then pull forwards towards the front of the appliance until the knob stops At that point move the Burn Rate Air Control spring handle to 1 8 1 2 from the low setting 3 Medium high burn setting Burn Rate Air Control spring handle up to high position Then activate the ACC timer system by pushing the knob all the back toward the applia...

Page 13: ... the appliance Be sure the room is adequately ventilated and the flue unobstructed 5 Light the paper in the appliance NEVER light or rekindle fire with kerosene gasoline or charcoal lighter fluid the results can be fatal 6 Once the kindling is burning quickly add several full length logs 3 inches 76mm or 4 inches 102mm in diameter Be careful not to smother the fire Stack the pieces of wood careful...

Page 14: ... MUST be in contact with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket The baffle boards are FRAGILE Use extreme caution when loading firewood to prevent Cracking breaking or damaging the baffle boards DO NOT operate the appliance without baffle boards CAUTION WARNING Fire Risk Firebox damage due to improper baffl...

Page 15: ...ISSIPATE SMOKE AND ODORS Odors may be irritating to sensitive individuals Smoke detectors may activate CAUTION Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids clear of appliance Do NOT store flammable materials in the appliance s vicinity DO NOT USE GASOLINE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS Ap...

Page 16: ...t equipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work and air handler joints and seams taped or sealed L Negative Pressure K Clear Space Do NOT p...

Page 17: ...eed is increased CONTACT YOUR DEALER for additional information regarding operation and troubleshooting Visit www quadrafire com to find a dealer M Frequently Asked Questions Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids clear of appliance Do NOT store flammable materials in the appliance s vicinity DO NOT USE GASOLINE LANTERN FUEL KEROSENE CHARCOAL LIGHTER F...

Page 18: ... season or more frequency if chimney exceeds or is under 14 16 ft 4 3m 4 8m measured from bottom of appliance This will prevent pipe blockage poor draft and chimney fires Always burn dry wood to help prevent cap blockage and creosote build up Firebrick Ash Removal WEEKLY or After Every 25 Loads of Wood Ashes must be cool before you can dispose of the ashes in a non combustible container Firebrick ...

Page 19: ... described in your owner s manual Figure 19 2 Access Cover Handle Insert Access Cover Handle handle into slot of ARS Cover to remove ARS Cover for cleaning ash out of firebox Injury Risk Gloves recommended May have sharp edges CAUTION Fire Risk Make sure Ash Removal System door is sealed tight against the gasket Air leakage may cause Over fire condition Flame and or smoke spillage Wood to burn too...

Page 20: ...4mm of firebox lip By Homeowner Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders ...

Page 21: ...n Check for adequate vent height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to Building a Fire Section Flue blockage such as birds nests or leaves in termination cap H...

Page 22: ...t is flush with the side of the appliance A Glass Replacement Door Assembly Replace with 5mm ceramic glass only 1 Ensure that the fire is out and the appliance is cool to the touch 2 Protect a table or counter top with padding or towels Protect your hands and wear gloves to prevent injury 3 Remove the door with the broken glass by lifting the door up and off of the hinges 4 Lay door face down on a...

Page 23: ... a metal container 2 The baffle board has 2 pieces With the ceramic blanket still in place slide one baffle piece over the top of other one and pull out top piece through the door opening and then remove bottom baffle piece Figure 23 2 3 Remove the ceramic blanket 4 Re install the baffle pieces one piece at a time Be sure the baffle boards are even with the front manifold tube and is resting on al...

Page 24: ...e bolts with penetrating oil for at least 15 minutes before trying to remove them Replacing Tube Channel Assembly 1 Slide one gasket onto each tube 2 Slide the tube channel assembly into side of firebox and insert each tube into the corresponding hole in the tube channel rack starting with the back hole first 3 Make sure tube channel assembly is flush against the side of the appliance and secure w...

Page 25: ...August 13 2018 7037 171E 25 4300 Wood Stove Series ACC A Service Maintenance Log Date of Service Performed By Description of Service 6 Reference Materials ...

Page 26: ...26 7037 171E August 13 2018 4300 Wood Stove Series ACC Date of Service Performed By Description of Service ...

Page 27: ...vice Parts R 43M ACC Beginning Manufacturing Date Oct 2006 Ending Manufacturing Date Active Wood Stove Part number list on following page 43M ACC GT Oct 2006 Jan 2007 43M ACC NT Oct 2006 Jan 2007 1 2 3 4 5 7 6 8 9 10 11 12 13 14 15 43M ACC MBK 08 18 B 43M ACC ...

Page 28: ...y 2 SRV7037 112 Y 9 Brick Retainer 7033 149 10 Tube Channel Assembly Manifold Tubes SRV7033 023 Y 11 Label Burn Rate Air Control SRV7033 160 12 Label Start Up Air Control Acc SRV7033 166 13 Panel Assembly Right Side 7037 006 14 Tube Channel Access Cover Top SRV7033 237 15 1 Burn Rate Control Assembly 7037 004 Y 15 2 Spring Handle 1 4 Gold Pre SN 0070030424 832 0630 Y Spring Handle 1 4 Nickel 250 8...

Page 29: ...RT NUMBER 16 Brick Assembly Complete Set Pkg of 20 SRV7037 003 16 1 Brick 9 x 4 5 x 1 25 Qty 12 Reg 16 2 Brick 6 x 4 5 Qty 4 Reg 16 3 Brick 9 x 4 5 with angle Qty 1 Reg 16 4 Brick 9 x 3 with angle Qty 1 Reg 16 5 Brick small Qty 2 Reg Brick Uncut Pkg of 1 832 0550 Pkg of 6 832 3040 17 Pedestal Assembly 17 1 Pedestal Riser 7033 207 17 2 Pedestal Base 7033 163 17 3 Strip Oak Trim No longer available ...

Page 30: ...3 Door Handle Assembly 832 0540 Cam Latch SRV430 1141 Key Cam Latch SRV430 1151 Nut Locking Door Handle Pkg of 24 226 0100 24 Y Door Handle Formed SRV430 1131 18 4 Spring Handle Door 1 2 Gold 832 0620 Y Nickel 250 8330 Y Black SRV7000 613 Y 18 5 Trim Ring For Door Trim door assembly only No longer available 430 2682 No longer available 430 5340 18 6 Door Glass Assembly 15 1 2 W x 13 3 8 H 7000 012...

Page 31: ...acement Blower 812 4900 Y Gasket Manifold Pkg of 4 7038 168 4 Y Logo Quadra Fire Gold 200 3180 Nickel 200 3240 Paint Touch Up Black 812 0910 Outside Air Kit Floor Rear OAK ACC Outside Air Collar Assembly 7033 039 Outside Air Shield SRV33271 Y FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head 1 4 20 X 1 Pkg of 10 25221A 10 Y Button Head 1 4 20 X 5 Pkg of 20 32...

Page 32: ...ve Series ACC Service Parts R 43ST ACC B Beginning Manufacturing Date Sept 2016 Ending Manufacturing Date Active Step Top Model Wood Stove Part number list on following page 08 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 20 16 C 43ST ACC B ...

Page 33: ...embly Side Left 7037 011 4 Brick Assembly See following pages ARS Cast Components SRV7037 038 5 ARS Access Cover SRV7038 196 Y 6 ARS Channel SRV7061 184 Y 7 ARS Latch Assembly SRV7062 034 Y 8 ARS Door Assembly SRV7060 048 Y 9 ARS Gasket SRV7033 296 Y Handle Access Cover SRV7038 197 10 Rear Channel Assembly 7033 002 Y 11 Tube Support Rack 7033 148 12 Brick Retainer 7033 149 13 Ceramic Fiber Blanket...

Page 34: ... Qty 1 Reg 4 6 Brick small Qty 2 Reg Brick Uncut Pkg of 1 832 0550 Pkg of 6 832 3040 20 1 Burn Rate Control Assembly 7037 004 Y 20 2 Spring Handle 1 4 Gold 832 0630 Y Nickel 250 8340 Y 20 3 Door Gasket Front Rear Air Timer Doors 7033 282 Y 20 4 Timer Air Control Assembly SRV7037 018 Y Rear Air Door Assembly 7037 013 Y 20 5 Rear Air Control Arm Assembly 7037 005 Y 20 6 Knob Start Up Control Knob SR...

Page 35: ...Kit Ash Removal System Black LEG KIT BK Nickel LEG KIT NL 21 1 Ash Pan Assembly 7033 008 21 2 Legs Queen Anne Black 831 1240 Nickel LEGS QANL 21 3 Leg Mount Kit SRV7037 132 Ash Pan Leg ARS Ash Pan Removal System 7033 050 Component Pack Leg Step Top Includes Gasket For Ash Removal Fasteners 7033 048 Pedestal PED KIT 43 21 4 Pedestal Assembly 7033 013 21 5 Ash Pan Assembly 7033 010 Ash Pan Door Hand...

Page 36: ... 0250 Qty 2 Nickel SRV430 5320 22 2 Rope Door 3 4 x 84 Field cut to Size 7 Ft Length 832 1680 Y 22 3 Door Glass Assembly 15 1 2 W x 13 3 8 H 7000 012 Y Gasket Glass Tape Field cut to Size 5 Ft Length 832 0460 Y 22 4 Glass Frame Set Qty 4 Pc 832 0350 22 5 Door Handle Assembly Spring 832 0540 Fiber SRV7033 071 Spring Handle 1 2 Gold 832 0620 Y Nickel 250 8330 Y Cam Latch SRV430 1141 Key Cam Latch SR...

Page 37: ...10 7000 694 10 Outside Air Collar Assembly 7033 039 Outside Air Kit Floor Rear OAK ACC Outside Air Shield SRV33271 Y Paint Touch Up 812 0910 Snap Disc Bracket Assembly 7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Upgrade Door Nickel Nickel Handles Hinge Pins Logo UK DRNL Wire Harness Blower 7033 262 FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head 1 ...

Page 38: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dealership purchased from ________________________________________ Dealer phone _1 _____ _____ ______ Notes ________________________________________________________________________________________ ______...