Page 20
October 24, 2011
Castile & Santa Fe CE Pellet Stove
R
7068-112B
Straight Back Against Wall
Millimeters
A
Back Wall to Appliance
50
B
Side Wall to Appliance
160
Corner Installation
Millimeters
C
Walls to Appliance
50
Vertical Installation
Millimeters
D
Back Wall to Flue Pipe
76
E
Side Wall to Cast Top
152
F
Back Wall to Appliance
178
Installations with:
76mm to 76mm Top Vent Adapter and
76mm to 152mm Offset Adapter
Corner Installation
Millimeters
G
Walls to Appliance
50
H
Side Wall to Flue Pipe
76
Alcove Installation
Millimeters
Minimum Alcove Height
1092
Minimum Alcove Side Wall
152
Minimum Alcove Width
965
Maximum Alcove Depth
914
Dimension to Corner
Millimeters
I
Flue Center Line (Santa
Fe/ Castile)
217 / 264
J
Back of Top Vent Adapter
232
B. Clearances to Combustibles
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
WARNING
Failure to comply may cause house fire.
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
•
Illustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design
preference.