Page  8

October 24, 2011

Castile & Santa Fe CE Pellet Stove 

R

7068-112B

A. Fire Safety

To  provide  reasonable  fire  safety,  the  following  should  be 

given serious consideration:
•  Install at least one smoke detector and CO

 

monitor on each 

floor of your home.

•  Locate detectors away from the heating appliance and close 

to the sleeping areas.  

•  Follow  the  detector’s  manufacturer’s  placement  and 

installation instructions and maintain regularly.  

•  Conveniently locate a fire extinguisher to contend with small 

fires.

•  In the event of a hopper fire:

•  Evacute the house immediately.

•  Notify fire department.

B. Combustible/Non-Combustible Materials

• 

Combustible Material

 

Material  made  of  or  surfaced  with  wood,  compressed 

paper,  plant  fibers,  plastics,  or  any  material  capable 

of  igniting  and  burning,  whether  flame-proofed  or  not, 

plastered or unplastered.

• 

Non-combustible Material

  Material which will not ignite and burn. Such materials are 

those consisting entirely of steel, iron, brick, tile, slate, 

glass or plasters, or any combination thereof.

• 

Firestop

 

Non-combustible Sealant Material

 

  Sealants which will not ignite and burn.

Clinkers
Minerals and other non-combustible materials such as sand 

will turn into a hard, glass-like substance called a clinker when 

heated in the firepot. 
Trees from different areas will vary in mineral content.  That 

is why some fuels produce more clinkers than others. 
Moisture
Always burn dry fuel.  Burning fuel with high moisture content 

takes  heat  from  the  fuel  and  tends  to  cool  the  appliance, 

robbing heat from your home.  Damp pellet fuel can clog the 

feed system.
Size
•  Pellets are either 6 or 8mm in diameter

•  Length should be no more that 38mm

•  Pellet  lengths  can  vary  from  lot  to  lot  from  the  same 

manufacturer

•  Due to length variations, the flame height (feed rate) may 

need adjusting occasionally.  See 

page 10 

for instructions.

Performance
•  Higher ash content requires the ash drawer to be emptied 

more frequently

•  Hardwoods require more air to burn properly

•  Premium wood pellets produce the highest heat output.

•  Burning pellets longer than 38mm can cause an inconsistent 

fuel feed rate and/or missed ignitions.

C.  Fuel Material and Fuel Storage

Pellet fuel quality can greatly fluctuate.  We recommend that 

you buy fuel in multi-ton lots whenever possible.  However, 

we do recommend trying various brands before purchasing 

multi-ton lots to ensure your satisfaction.
Fuel Material
•  Made from sawdust or wood by-products

•  Depending on the source material it may have a high or 

low ash content.

Higher Ash Content Material 

•  Hardwoods with a high mineral content

•  Fuel that contains bark

•  Standard grade pellets and high ash pellets
Lower Ash Content Material

•  Softwoods

•  Fuels with low mineral content

•  Premium grade pellets

CAUTION

Do not b

urn fuel that contains an additive; 

(such as soybean oil

).

 

•  May cause hopper fires

  •  Damage to product may result 

Storage
•  Wood pellets should be left in their original sealed bag until 

using to prevent moisture absorption.

•  Do  not  store  any  pellet  fuel  within  the  clearance 

requirements  or  in  an  area  that  would  hinder  routine 

cleaning and maintenance.

CAUTION!  

Tested and approved for wood pellets. Burning 

of any other type of fuel voids your warranty.

Summary of Contents for CASTILE-CE-MBK

Page 1: ...esponsible for use and operation Read understand and follow these instruc tions for safe installa tion and operation DO NOT DISCARD WARNING Hot glass will cause burns Do not touch glass until it is co...

Page 2: ...voeding 470 W Rated Voltage Tension nominale Nominale spanning 230 V 50 Hz Safety clearance distance back Distance de d gagement de s curit retour Veiligheidsafstand afstand terug 50 mm Safety clearan...

Page 3: ...lame Height Adjustment Feed Rate 10 J Ignition Cycles 10 K Clear Space 10 Section 3 Maintaining Servicing Appliance A Proper Shutdown Procedures 11 B Quick Reference Maintenance Chart 11 C General Mai...

Page 4: ...Page 4 October 24 2011 Castile Santa Fe CE Pellet Stove R 7068 112B...

Page 5: ...R October 24 2011 Page 5 Castile Santa Fe CE Pellet Stove 7068 112B...

Page 6: ...Overfire Install any component not approved by Hearth Home Technologies Install parts or components not Listed or approved Improper installation adjustment alteration service or maintenance can cause...

Page 7: ...E children in same room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and...

Page 8: ...ppliance robbing heat from your home Damp pellet fuel can clog the feed system Size Pellets are either 6 or 8mm in diameter Length should be no more that 38mm Pellet lengths can vary from lot to lot f...

Page 9: ...our appliance will automatically light and deliver heat When the room is up to temperature and the thermostat is satisfied the red call light will go off and the appliance will shut down 2 Heat Output...

Page 10: ...minutes This blower transfers heat from your appliance into the room and will continue to run after the thermostat has stopped calling for heat until the appliance has cooled down 3 Occasionally the a...

Page 11: ...build up OR X Ash Removal from Firebox Every 5 bags or more frequently depending on the fuel type or ash build up OR X Beneath Heat Exchanger Every 1 ton of fuel OR X Blower Combustion Exhaust More f...

Page 12: ...ust blower and vent system b Plug in your appliance if unplugged and turn the thermostat on and immediatley shut it off to start the exhaust blower on its cycle time It will pull fly ash out the exhau...

Page 13: ...d close cast hinge face 10 Cleaning the Hopper Frequency Monthly or after burning 50 bags of fuel By Homeowner After burning approximately 1 ton of fuel you will need to clean the hopper to prevent sa...

Page 14: ...e Technician Task Contact your local dealer 14 Cleaning Convection Blower Requires No Lubrication Frequency Yearly or every 25 bags or more fre quently depending on operating environ ment By Qualified...

Page 15: ...and possible hopper fires Poor quality pellet fuel or lack of maintenance can create conditions that make the firepot fill quickly with ashes and clinkers This condition makes the appliance susceptib...

Page 16: ...oot 3 Excessive build up of ash See solution 4 The lower burn settings will produce more ash the higher burn settings produce less The more it burns on low the more frequent cleaning of the glass is r...

Page 17: ...affect the loca tion of the vent termination Marginal Location Below peak Location NOT recommended Not the highest point of the roof Wind loading possible Multi level Roofs Windward Leeward Recommende...

Page 18: ...dealer any parts damaged in shipment All labels have been removed from the glass door Plated surfaces have been wiped clean with a soft cloth if applicable Read all the instructions before starting th...

Page 19: ...ew Figure 20 1 Top View Figure 20 3 Side View Figure 20 4 Side View with Top Vent Adapter 658mm 324mm 540mm 729mm 426mm 715mm 653mm 95mm 64mm 73mm 683mm 609mm 626mm 305mm 609mm 725mm 405mm 582mm 431mm...

Page 20: ...Appliance 50 H Side Wall to Flue Pipe 76 Alcove Installation Millimeters Minimum Alcove Height 1092 Minimum Alcove Side Wall 152 Minimum Alcove Width 965 Maximum Alcove Depth 914 Dimension to Corner M...

Page 21: ...tion Figure 22 3 Figure 22 4 Must extend 51mm beyond each side of pipe shaded area C Hearth Pad Requirements If the current flooring is made from wood provide adequate surface protection according to...

Page 22: ...service shall be the same as minimum clearance to vinyl soffits Clearance of a termination cap above electrical service will be 305mm minimum Location of the vent termination must not obstruct or inte...

Page 23: ...erformance of the chimney system caused by Inadequate draft due to environmental conditions Downdrafts Tight sealing construction of the structure Mechanical exhausting devices D Draft To minimize the...

Page 24: ...with at least 3 screws through each joint 5 DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT 6 DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE NOTE All pipe...

Page 25: ...foot Hearth Home Technologies recommends any installation requiring more than two 90 elbows or more than 4 5m of venting to use 102mm vent NOTICE These are guidelines for successful venting of your pe...

Page 26: ...and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference A Alcove Figure 27 1 All minimums listed are to a combus...

Page 27: ...actures listed air clearances to combustibles and installation instructions for all reduced air clearances installations The stove must be connected to a flue pipe conforming to current standards UNI...

Page 28: ...FE Non combustible Hearth Pad Airtight Cleanout Door Cleanout cover Sheathing 76mm Minimum 25mm Clearance Flashing Fireclay flue Liner with Airspace Concrete Cap 25mm Clearance with Firestop 152mm Mi...

Page 29: ...e Horizontal Termination Cap 51mm Minimum 152mm Minimum From Glass NOTICE Please note that while the minimum clearance for the termination cap is 152mm there is the possibility of soot build up around...

Page 30: ...e saw to cut opening in wall Cut a 64 to 76mm open ing on inside wall and a 76 to 89mm opening on outside of house 2 Remove cover plate and then install the collar assembly 3 Use hose clamp to secure...

Page 31: ...tional programmable thermo stat or remote control It is equipped with an adjustable heat anticipator The current rating is 05 amps The anticipator needs to be adjusted to the lowest setting available...

Page 32: ...instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc tions for safe installa tion and operation DO NOT DISCARD Date purchased...

Reviews: