Page 10
7021-130E
November 13, 2013
Castile-B FS Pellet Stove
*L Exception
for Horizontal Installations:
See Figure 10 2
USA INSTALLATIONS
: A non-combustible floor protection is
recommended extending beneath the flue pipe when installed
with horizontal venting or under the Top Vent Adapter with
vertical installation.
CANADA INSTALLATIONS
: A non-combustible floor pro
-
tection extending beneath the flue pipe is
required
with hori-
zontal venting or under the Top Vent Adapter with vertical
installation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
C. Hearth Pad Requirements (UL and ULC)
Use a non-combustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance “M” from the surface of the glass
door.
Hearth Pad Requirements
Inches Millimeters
K
Sides
2
51
L*
Back
2
51
M
Front
6
152
L*
K
K
M
Hearth Pad Requirements
Inches Millimeters
K
Sides
8
203
L*
Back
2
51
M
Front
18
457
USA Installations
CANADA Installations
Figure 10.2
Figure 10.1