November 13, 2013
7021-130D
Page 21
Castile-B FS Pellet Stove
1
.
A 12 volt AC thermostat is required to operate this pellet
appliance. You may use the included wall mount thermo
-
stat or purchase an optional programmable thermostat
or remote control. It is equipped with an adjustable
heat anticipator. The current rating is .05 amps. The
anticipator needs to be adjusted to the lowest setting
available.
2. When mounting a thermostat on a wall, be sure to follow
your thermostat installation instructions carefully.
NOTE: Thermostat must be mounted level for
accurate readings. The thermostat should be
mounted on an inside wall and not in direct line
with the appliance convection air.
NOTE: If the thermostat is located too close to the
appliance, you may need to set the temperature
setting slightly higher to maintain the desired
temperature in your home.
3. There is a 4 screw terminal block located on the back
lower right corner of the stove directly above the power
cord inlet. The center 2 screws are for the thermostat
wires.
F. Thermostat Installation
Shock hazard.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong recep
-
tacle.
• Route cord away from appliance.
•
Do NOT route cord under or in front of appliance.
CAUTION
TERMINAL BLOCK
CENTER 2 SCREWS FOR
THERMOSTAT WIRES
POWER OUTLET
FUSE
Fuse
Figure 21.1