November 13, 2013
7021-130D
Page 37
Castile-B FS Pellet Stove
11
Reference Materials
When describing the location of a component,
it is always AS YOU FACE THE FRONT OF
THE APPLIANCE.
NOTE:
Do
NOT
open the control box.
This will void the
warranty. FolIow proper shutdown procedures first if
you need to plug in or remove the control box.
1. Control Box
a. The control box is located on upper right side of
appliance, behind the right side panel and above the
vacuum switch.
b. There is a light located inside of the control box. The
internal light will turn green when the appliance has
reached a temperature of 175
o
F (79
°
C) in the firepot.
and will turn red when it reaches 600
o
F (315
°
C).
c. There is also an internal blue light located in the upper
left corner of the control box. When you plug in the
appliance the blue light will automatically start blinking
6 times in a row for 60 seconds and then will stop.
A. Component Function
7. Heat Exchangers
The heat exchangers transfer hot air from the exhaust system
into convecton air. Remove the stainless steel top baffle to
access the heat exchangers. There are 2 clean out rods
located under the heat exchangers.
8
.
Heat Output Switch
The heat output switch is located on the upper right rear
corner. The funtion of the heat ouput switch is to regulate
the burn rates; low, medium and high settings.
9. Hopper Switch
The hopper switch is located in the upper right hand corner
of the hopper. This switch is designed to shut down the feed
motor whenever the hopper lid is opened.
10. Igniter
The igniter is mounted on the base of the firepot. Combustion
air travels over the red hot igniter creating super heated air
that ignites the pellets.
11. Junction Box And Wiring Harness
The junction box is located on the right side of the appliance,
behind the right side panel. The junction box and wiring
harness are replaced as one component.
12. Power Supply
The power outlet is located on the right rear of the appliance
on the front of the junction box. Check the wall receptacle
for 120 volt, 60 Hz (standard current). Make sure the outlet
is grounded and has the correct polarity. A good surge
protector is recommended. When operating with a generator
you need a least 600 watts of power, or with an inverter at
least 800 watts of power available for the appliance during
the start cycle.
13. Red Call Light
The red call light is on the front of the junction box, behind
the control box. The function of the red call light is to indicate
that the thermostat is calling for heat.
14. Reset Button
The reset button is located on the back of the appliance on
the upper right corner of the side panel under the heat output
control switch. The function of the button is to momentarily
open the thermostat circuit, which restarts the system.
15. Thermocouple
The thermocouple is located on top of the firepot inside
the thermocouple cover (ceramic protection tube). The
thermocouple sends a millivolt signal to the control box
indicating the preset temperatures of the green and red lights
have been obtained.
2. Convection Blower
The convection blower is mounted at the bottom rear of the
appliance. There are 2 impellers, one on each side of the
motor. The convection blower pushes heated air through the
heat exchange system into the room.
3. Combustion Blower
The combustion blower is located on the right side of
appliance and is designed to pull the exhaust from the
appliance and push it out through the venting system.
4. Feed System
The feed system is located on the right side of the appliance
and can be removed as an entire assembly. The assembly
includes the feed motor, mounting bracket, bearing and feed
spring (auger). The hollow feed spring (auger) pulls pellets
up the feed tube from the hopper area and drops them down
the feed chute into the firepot.
5. Firepot
The firepot is made of high quality ductile iron and has a
cleaning pull-out rod. The floor of the firepot opens for
cleaning when you pull out the rod. Be sure that the floor
returns to a completely closed position or your appliance will
not operate properly.
6. Fuse
The fuse is located on the front of the junction box on the
right side of appliance. The fuse will blow should a short
occur and shut off power to the appliance.