November 13, 2013
7021-130D
Page 5
Castile-B FS Pellet Stove
2
Getting Started
A. Design, Installation & Location Consider-
ations
Warning! Risk of Fire
Damaged parts could impair safe
operation. Do NOT install damaged, incomplete or substitute
components.
1. Appliance Location
NOTICE: Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult insurance carrier, local building inspector, fire
officials or authorities having jurisdiction over restrictions,
installation inspection and permits.
It is a good idea to plan your installation on paper, using
exact measurements for clearances and floor protection,
before actually beginning the installation
Consideration must be given to:
• Safety, convenience, traffic flow
• Placement of the
chimney and chimney connector.
• If you are not using an existing chimney, place the appli
-
ance where there will be a clear passage for a factory-
built listed chimney through the ceiling and roof.
• Installing an optional outside air kit would affect the loca
-
tion of the vent termination.
CAUTION!
If burning shelled field corn, you must use ap-
proved venting specifically designed for corn to prevent corro-
sion or degradation. Follow the instructions from the venting
manufacturer.
Since pellet exhaust can contain ash, soot or sparks, you
must consider the location of:
• Windows
• Air Intakes
• Air Conditioner
• Overhang, soffits, porch roofs, adjacent walls
• Landscaping, vegetation
When locating vent and venting termination, vent above roof
line when possible.
Marginal Location:
• Below peak
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Recommended Location:
• Above peak
Recommended:
• Insulated exterior chase
in cooler climates
Recommended Location:
• Above peak
• Inside heated space
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Marginal Location:
• Wind loading possible
NOTICE: Locating the appliance in a location of
considerable air movement can cause intermittent smoke
spillage from appliance. Do not locate appliance near:
• Frequently open doors
• Central heat outlets or returns
Figure 5.1