May 12, 2014

7021-130F

Page  11

Castile-B FS Pellet Stove 

Do not terminate vent in any enclosed or semi-enclosed 
area such as a carport, garage, attic, crawl space, under a 
sun deck or porch, narrow walkway or closely fenced area, 
or any location that can build up a concentration of fumes 
such as a stairwell, covered breezeway, etc.

CAUTION

A.  Chimney and Exhaust Connection

Fire Hazard.

•  Only LISTED venting components may be 
used.

•  NO OTHER vent components may be used.
Substitute or damaged vent components may 
impair safe operation.

WARNING

B.  Venting Termination Requirements

1

Termination must exhaust above air inlet elevation.  It 

is recommended that at least 60 inches (1.5m) of verti-
cal pipe be installed when appliance is vented directly 
through a wall.  This will create a natural draft, which 
will help prevent the possibility of smoke or odor venting 
into the home during a power outage.  It will also keep 
exhaust from causing a nuisance or hazard by exposing 
people or shrubs to high temperatures.  The safest and 
preferred venting method is to extend the vent vertically 
through the roof.

2

Distance from

 

doors and opening windows, or gravity or 

ventilation air inlets into building:

a.  Not less than 48 inches (1.2m) below;
b.  Not less than 48 inches (1.2m) horizontally from;
c.  Not less than 12 inches (305mm) above.

3.  Distance from permanently closed windows:

a.  Not less than 12 inches (305mm) below, horizontally 

from or above.

4

Distance between

 

bottom of termination and grade should 

be 12 inches (305mm) minimum.  This is conditional upon 
plants in the area, and nature of grade surface.  The 
grade surface must be a noncombustible material (i.e., 
rock, dirt).  The grade surface must not be lawn.  Distance 
between bottom of termination and public walkway should 
be 84 inches (2.13m) minimum.

5

 

Distance to combustible

 

materials must be 24 inches 

(610mm) minimum.  This includes adjacent buildings, 
fences, protruding parts of the structure, roof overhang, 
plants and shrubs, etc.

6.  Termination Cap Location (Home Electrical Service)

•  Side-to-side clearance is to be the same as minimum 

clearance to vinyl inside corners.

•  Clearance of a termination cap below electrical service 

shall be the same as minimum clearance to vinyl sof-
fi ts.

•  Clearance of a termination cap above electrical service 

will be 12 inches minimum.

•  Location of the vent termination must not obstruct or 

interfere with access to the electrical service.

4

Vent Information

Vent surfaces get HOT, can cause burns if 
touched.  Noncombustible shielding or guards 
may be required

WARNING

1.

 

Chimney & Connector

:  Use 3 or 4 inch (76-102mm)  

diameter type "L" or "PL" venting system.  It can be vented 
vertically or horizontally.

2.

 Mobile Home: 

Approved for all Listed pellet vent.  If using 

the 3 inch (76mm) vertical Top Vent Adapter Kit or the 3 
to 6 inch (76-152mm) Top Vent Offset Adapter, use Listed 
double wall fl ue connector.  A Quadra-Fire Outside Air Kit 
must be used with manufactured home installations.

3.

 Residential: 

 The 3 inch (76mm) vertical Top Vent Adapter 

Kit and the 3 to 6 inch (76-152mm) Top Vent Offset Adapter 
are tested to use 24 gauge single wall fl ue connector or 
Listed double wall fl ue connector to Class A Listed metal 
chimneys, or masonry chimneys meeting International 
Conference of Building Offi cials (ICBO) standards for solid 
fuel appliances.

4.

  INSTALL VENT AT CLEARANCES SPECIFIED BY THE 

VENT MANUFACTURER.

5

.  Secure exhaust venting system to the appliance with at 

least 3 screws.  Also secure all connector pipe joints with 
at least 3 screws through each joint.

6.  DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST 

VENTING SYSTEM OF THIS UNIT.

7.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE 

SERVING ANOTHER APPLIANCE.

NOTE: All pipe must be welded seam pipe whenever pos-
sible.  Seal pipe joints with high temperature silicone (500°F 
[260°C] minimum rated only).  Do not put silicone inside 
of pipe.

NOTE:  If burning shelled fi eld corn, you must use approved 
venting specifi cally designed for corn.  Follow the instruc-
tions from the venting manufacturer.

Summary of Contents for CASTILE-MBK-B

Page 1: ...requirements in your area CAUTION Tested and approved for wood pellets and shelled field corn fuel only Burning of any other type of fuel voids your warranty CAUTION WARNING Hot glass will cause burns...

Page 2: ...des codes locaux pour les pr cautions requises pour passer une chemin e travers un mur ou un plafond combustibles et les compensations maximums Inspectez et nettoyez la chemin e fr quemment Ne pas co...

Page 3: ...n A Chimney Exhaust Connection 11 B Venting Termination Requirements 11 C Equivalent Feet of Pipe 12 D Pipe Selection Chart 12 Section 5 Venting Systems A Alcove 13 B Through the Wall 14 C Vertical 15...

Page 4: ...e Technologies Operate the appliance without fully assembling all components Overfire Install any component not approved by Hearth Home Technologies Install parts or components not Listed or approved...

Page 5: ...loca tion of the vent termination CAUTION If burning shelled field corn you must use ap proved venting specifically designed for corn to prevent corro sion or degradation Follow the instructions from...

Page 6: ...appliance is drafting successfully all combustion byproducts are exiting the home through the chimney Considerations for successful draft include Preventing negative pressure Location of appliance and...

Page 7: ...ials have been met 8 The masonry chimney is inspected by a profes sional and is clean or the factory built metal chimney is installed according to the manufac turer s instructions and clearances 9 The...

Page 8: ...nsions Figure 8 2 Front View Figure 8 1 Top View Figure 8 3 Side View Figure 8 4 Side View with Top Vent Adapter 24 in 609mm 24 5 8 in 626mm 12 in 305mm 24 in 609mm 28 9 16 in 725mm 15 15 16 in 405mm...

Page 9: ...Appliance 2 51 H Side Wall to Flue Pipe 3 76 Alcove Installation Inches Millimeters Minimum Alcove Height 43 1092 Minimum Alcove Side Wall 6 152 Minimum Alcove Width 38 965 Maximum Alcove Depth 36 91...

Page 10: ...required with hori zontal venting or under the Top Vent Adapter with vertical installation Must extend 2 inches 51mm beyond each side of pipe shaded area C Hearth Pad Requirements UL and ULC Use a no...

Page 11: ...otruding parts of the structure roof overhang plants and shrubs etc 6 Termination Cap Location Home Electrical Service Side to side clearance is to be the same as minimum clearance to vinyl inside cor...

Page 12: ...ere above the diagonal line a 4 inch 102mm diam eter pipe is required The chart reveals that a 90 elbow is 5 times as restrictive to the flow of exhaust gases under positive pressure as 1 foot of hori...

Page 13: ...S ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference A Alcove Figure 13 1 All minimums listed are to a combustible surface Minimum Maxi...

Page 14: ...ust be a minimum of 6 inches 152mm from the wall Approved for mobile home instal lations Must use 3 or 4 inch 76 102mm L or PL listed pellet venting or listed double wall pipe and a Quadra Fire Outsid...

Page 15: ...Single wall pipe is approved for residential installations only C Vertical D Through The Wall Vertical Firestop Flashing Rain Cap 6 in 152mm Min Non combustible Hearth Pad 3 in 76mm Min Clean out Cov...

Page 16: ...nry Figure 16 1 Figure 16 2 Non combustible Hearth Pad Airtight Clean out Door Clean out cover Sheathing 3 in 76mm minimum 1 in 25mm clearance Flashing Fireclay flue liner with airspace Concrete Cap 1...

Page 17: ...ling the vent system for use in a mobile home 8 Installation shall be in accordance with the Manufactur ers Home Safety Standard HUD CFR 3280 Part 24 Installation must comply with Manufactured Home an...

Page 18: ...interior wall Tools Needed Phillips headscrewdriver wire cutters hole saw or jig saw CAUTION Never draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or gar...

Page 19: ...tion Figure 19 5 Figure 19 4 Installing the Top Vent Adapter Top Vent Adapter 3 to 3 inch Rear Exhaust Outlet Use hole on each side as drilling guide Offset Collar 3 to 6 inch Mount with 4 screws Clea...

Page 20: ...overed under warranty Any placement varia tion other than shown here can cause excessive heat and shall void the appliance warranty Figure 20 2 1 Open door to expose the firebox 2 Install the left log...

Page 21: ...he thermostat should be mounted on an inside wall and not in direct line with the appliance convection air NOTE If the thermostat is located too close to the appliance you may need to set the temperat...

Page 22: ...ood pellets should be left in their original sealed bag until using This will prevent moisture absorption Shelled corn should be stored in a tight container where it will not absorb moisture from damp...

Page 23: ...nutes after start up and again in 5 minutes This will fill the feed system and allow the appliance to begin dropping pellets The appliance will continue to run as long as the thermostat is calling for...

Page 24: ...ped calling for heat until the appliance has cooled down 3 Occasionally the appliance may run out of fuel and shut itself down When this happens the red call light will be on Figure 24 1 To restart it...

Page 25: ...does not affect the operation or longevity of your appliance 2 Ash buildup on glass 2 This is normal Clean the glass 3 Glass has turned dirty 3 Excessive build up of ash The lower burn settings will p...

Page 26: ...clean Make sure front door is closed Replace control box Call light on No fire Partially burned fuel in firepot Firepot clean out plate not closed Firepot is dirty missed ignition Check that firepot...

Page 27: ...s of vacuum Empty hopper of fuel Use a wet dry vacuum cleaner to remove remaining fuel from hopper including feed tube Check feed chute for obstructions Loosen 2 feed assembly mounting screws and ligh...

Page 28: ...less steel baffle from firebox to clean ash from on top of baffle Clean behind rear brick panels Change fuel brand to premium Check that firepot clean out plate is fully closed Reduce feed rate using...

Page 29: ...Removal from Firebox More frequently depending on the fuel type or ash build up OR X Beneath Heat Exchanger Every 1 ton of fuel OR X Blower Combustion Exhaust More frequently depending on the fuel ty...

Page 30: ...sal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled Other waste shall not be plac...

Page 31: ...left behind from the use of the cleaning rods for the heat exchanger tubes c The ash will be resting on the back of the baffle This will require removing the cast baffle Please refer to page 35 for a...

Page 32: ...on adjustable but the gasketing between the glass and firebox should be inspected periodically to make sure there is a good seal 16 Preparing Firebox for Non Burn Season Frequency Yearly By Homeowner...

Page 33: ...An inefficient and non economical method of burning of fuel caused by poor quality pellet fuel is shown in Figure 33 2 The correct flame size when good quality premium pellet fuel is burned is shown i...

Page 34: ...the thermostat block and disconnect the 2 yellow wires e Remove the 2 screws from the power inlet and rotate it through the hole and out of the screen leaving the wires attached f Disconnect the vacuu...

Page 35: ...ont of the housing and very carefully bend the 2 housing sides out and bend the back of the housing away from the blower This allows for room to access the back 2 screws and nuts 4 total that is secur...

Page 36: ...el by loosening 2 screws do not remove and pull side panel away 3 The wire leads to the igniter are connected to the wire harness black wires with 1 4 inch male female spade connectors Disconnect the...

Page 37: ...for 120 volt 60 Hz standard current Make sure the outlet is grounded and has the correct polarity A good surge protector is recommended When operating with a generator you need a least 600 watts of p...

Page 38: ...ly reset itself 19 Snap Disc 3 Back Burn Protector 250 F Snap disc 3 is mounted on the back of the auger tube in the center of the appliance and has a red reset button To access it remove the right si...

Page 39: ...vection Blower Housing Feed Motor High Med Low Heat Output Switch Reset Button Reset Button Combustion Blower TERMINAL BLOCK CENTER 2 SCREWS FOR THERMOSTAT WIRES POWER OUTLET FUSE Fuse Red Call Light...

Page 40: ...chase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer d...

Page 41: ...Pellet Stove R Castile Pellet Insert WARRANTY CONDITIONS This warranty is void if LIMITATIONS OF LIABILITY 8 K N N OQ R U Z 8 88 U 8 U Q 8 N N Q Z R N U Q 8 R Z N N 88 N U Q 8 N O K WARRANTY EXCLUSION...

Page 42: ...Page 42 7021 130F May 12 2014 Castile B FS Pellet Stove...

Page 43: ...May 12 2014 7021 130F Page 43 Castile B FS Pellet Stove...

Page 44: ...502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302B2 6715724B2 6729551 6736133 6748940 6748942 6769426 6774802 6796302 6840261 6848441 6863064 6866205...

Reviews: