background image

 8 

 

 

 

 

                        7021-154J 

 

 

 

 

   May 12, 2017

CASTILE FREESTANDING

Straight Back Against  Wall

Inches

Millimeters

A

Back Wall to Appliance

2

51

B

Side Wall to Appliance

6

152

Corner Installation

Inches

Millimeters

C

Walls to Appliance

2

51

Vertical Installation

Inches

Millimeters

D

Back Wall to Flue Pipe

3

76

E

Side Wall to Appliance

6

152

F

Back Wall to Appliance

7

178

Corner Installation 

Inches

Millimeters

G

Side Wall to Appliance 

Corner

2

51

Installations with:

3 to 3 inch Top Vent Adapter and

3 to 6 inch Offset Adapter Kit

NOTE:

  Illustrations reflect typical installations and are FOR DESIGN PUR

-

POSES ONLY.

•  

I

llustrations/diagrams are not drawn to scale.

•  

Actual installation may vary due to individual design preference.

Hearth Pad Requirements

Inches

Millimeters

K

Sides

2

51

L*

Back

2

51

M

Front

6

152

*L Exception

 for Horizontal Installations:

USA INSTALLATIONS

:  A

 non

-combustible  floor  protec

-

tion is 

recommended extending beneath the flue pipe when 

installed  with  horizontal  venting  or  under  the  Top  Vent 

Adapter with vertical installation.

CANADA INSTALLATIONS

:  A

 non

-combustible floor pro

-

tection extending beneath the flue pipe 

is 

required

 

with hor

-

izontal venting or under the Top Vent Adapter with vertical 

installation.

C

C

E

G

G

L* 

 

Must extend 2 inches (51mm) beyond each 

side of pipe  (shaded area) 

Dimension to Corner

Inches Millimeters

I

Flue Center Line

10-3/8

264

J

Back of Top Vent Adapter

9-1/8

232

C L 

H

Side Wall to Flue Pipe

3

76

Alcove Installation

Inches

Millimeters

Minimum Alcove Height

43

1092

Minimum Alcove Side Wall

6

152

Minimum Alcove Width

38

965

Maximum Alcove Depth

36

914

B. Clearances to Combustibles (UL and ULC)

C. Hearth Pad Requirements (UL and ULC)

Use  a  non

-

combustible  floor  protector,  extending  beneath 

appliance and to the front

sides and rear as indicated.  Mea

-

sure front distance “M” from the surface of the glass door.

Fire Risk.

Comply with all minimum clearances to combustibles 

as specified. Failure to comply may cause house fire.

WARNING

Summary of Contents for CASTILE-MBK-B

Page 1: ...minimum clearances to combustibles as specified Failure to comply may cause house fire HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns Do not to...

Page 2: ...Components 5 E Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Clearances to Combustibles UL and ULC 8 C Hearth Pad Requirements UL and ULC 8 D Alcove 9 4 Vent Informatio...

Page 3: ...ped with 5mm ceramic glass Replace glass only with 5mm ceramic glass Please con tact your dealer for replacement glass D Electrical Rating 115 VAC 60 Hz Start 4 1 Amps Run 1 1 Amps E Mobile Home Appro...

Page 4: ...the installation Location of the appliance and chimney will affect performance Consideration must be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to mini...

Page 5: ...ermostat Wall Control Location The thermostat wall control s location will have some affect on the appliance s operation Maximum wire length from appliance is 100 feet 30 48m with continuous non splic...

Page 6: ...the party responsible for use and operation ATTENTION INSTALLER Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with not instead of the...

Page 7: ...7 3 Side View Figure 7 4 Side View with Top Vent Adapter 24 in 609mm 24 5 8 in 626mm 12 in 305mm 24 in 609mm 28 9 16 in 725mm 15 15 16 in 405mm 22 7 8 in 582mm 17 in 431mm 16 5 16 in 414mm 28 3 4 in...

Page 8: ...ecommended extending beneath the flue pipe when installed with horizontal venting or under the Top Vent Adapter with vertical installation CANADA INSTALLATIONS A non combustible floor pro tection exte...

Page 9: ...Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference D Alcove Figure 9 1 All minimums listed are to a combustible surface Minimum Maximum Inc...

Page 10: ...protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table be...

Page 11: ...t with your local HVAC professional to determine the ventilation demands for your house Vent Configurations To reduce probability of reverse drafting during shut down conditions Hearth Home Technologi...

Page 12: ...zontally from c Not less than 12 inches 305mm above 3 Distance from permanently closed windows a Not less than 12 inches 305mm below horizontally from or above 4 Distance between bottom of termination...

Page 13: ...2 If the equivalent length of pipe is 12 feet 3 7m with altitude of 6 000 feet 1829m you may use 3 or 4 inch 76 to 102mm diameter type L or PL vent H Pipe Selection Chart The chart will help you in de...

Page 14: ...cumulate ash and will need to be cleaned more often Try to keep them as short as possible ONE 90 ELBOW Total Horizontal Minimum Vertical Vent Diameter 4 0 3 5 5 3 6 6 3 7 7 3 8 8 4 9 9 4 10 10 4 11 11...

Page 15: ...stalla tions Must use 3 or 4 inch 76 102mm L or PL Listed pellet venting or Listed double wall pipe and a Quadra Fire Outside Air Kit in mobile homes NOTE In Canada where passage through a wall or par...

Page 16: ...an out Cover 24 in 610mm Minimum Ceiling Support 6 in 152mm Flue Connector 6 in 152mm Class A Chimney Connector Adapter 3 in to 6 in 76 152mm Top Vent Kit We recommend a minimum of 60 inches 1524mm ve...

Page 17: ...ce Concrete Cap 1 in 25mm clearance with firestop 6 in 152mm minimum Non combustible Hearth Pad Airtight clean out door Sheathing 2 in 51mm minimum Flashing 1 in 25mm clearance 1 in 25mm clearance wit...

Page 18: ...N Never draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage Flex Hose Hose Clamp Collar Assembly Trim Ring Termination Cap Assembly Hose Clamp Air I...

Page 19: ...hort horizontal pipe in the top vent adapter as a guide Install the 4 screws Figure 19 2 6 Install the vent pipe into the top vent adapter be sure to silicone all joints C Rear Vent Rear Vent to Top V...

Page 20: ...from appliance Do NOT route cord under or in front of appliance CAUTION The appliance comes standard with a wall thermostat and 25 of wire If you need to run more than 25 make sure you use a continuo...

Page 21: ...S FOR THERMOSTAT WIRES POWER OUTLET FUSE Fuse W R Figure 21 2 Press and pull to remove Press and pull to remove Figure 21 3 Thermostat Operation Digital display Digital display Back light Heat On or O...

Page 22: ...3280 Part 24 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arestor Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 22 1 CAUTION Never draw outside combustion ai...

Page 23: ...ssembly 7001 044 Outside Air Collar Assembly SRV7001 045 Trim Plate Outside Air Kit 412 7100 Pullrod Handle PULLROD HNDL Smart Batt Il 841 0970 Smart Stat Il 841 0960 Thermostat Mechanical 812 3760 Y...

Page 24: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deale...

Reviews: