8
7021-154J
May 12, 2017
CASTILE FREESTANDING
Straight Back Against Wall
Inches
Millimeters
A
Back Wall to Appliance
2
51
B
Side Wall to Appliance
6
152
Corner Installation
Inches
Millimeters
C
Walls to Appliance
2
51
Vertical Installation
Inches
Millimeters
D
Back Wall to Flue Pipe
3
76
E
Side Wall to Appliance
6
152
F
Back Wall to Appliance
7
178
Corner Installation
Inches
Millimeters
G
Side Wall to Appliance
Corner
2
51
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
NOTE:
•
Illustrations reflect typical installations and are FOR DESIGN PUR
-
POSES ONLY.
•
I
llustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design preference.
Hearth Pad Requirements
Inches
Millimeters
K
Sides
2
51
L*
Back
2
51
M
Front
6
152
*L Exception
for Horizontal Installations:
USA INSTALLATIONS
: A
non
-combustible floor protec
-
tion is
recommended extending beneath the flue pipe when
installed with horizontal venting or under the Top Vent
Adapter with vertical installation.
CANADA INSTALLATIONS
: A
non
-combustible floor pro
-
tection extending beneath the flue pipe
is
required
with hor
-
izontal venting or under the Top Vent Adapter with vertical
installation.
C
C
A
B
D
E
F
G
G
H
H
L*
K
K
M
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
Dimension to Corner
Inches Millimeters
I
Flue Center Line
10-3/8
264
J
Back of Top Vent Adapter
9-1/8
232
J
I
C L
H
Side Wall to Flue Pipe
3
76
Alcove Installation
Inches
Millimeters
Minimum Alcove Height
43
1092
Minimum Alcove Side Wall
6
152
Minimum Alcove Width
38
965
Maximum Alcove Depth
36
914
B. Clearances to Combustibles (UL and ULC)
C. Hearth Pad Requirements (UL and ULC)
Use a non
-
combustible floor protector, extending beneath
appliance and to the front
,
sides and rear as indicated. Mea
-
sure front distance “M” from the surface of the glass door.
Fire Risk.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
WARNING