Page 10
7022-122D
May 12, 2014
Castile Pellet Insert
Fire Risk.
Comply with all minimum clear-
ances to combustibles as speci-
fi ed.
WARNING
Failure to comply may cause
house fi re.
NOTE:
•
Illustrations
refl ect typical installations
and are FOR DESIGN PURPOSES
ONLY.
•
Illustrations/diagrams are not drawn to
scale.
•
Actual installation may vary due to
individual design preference.
A
C
B
D
C
B
0 in. Clearance To Exposed Section And Face Trim
B. Clearance To Combustibles, UL and ULC
Inches
Millimeters
A
Top of Hopper
Top Vent
2.0
51
Rear Vent
2.5
64
B
Side of Hopper
Top or Rear Vent
2.0
51
C
Back of Hopper
Top or Rear Vent
4.0
102
D
Vent Pipe to Combustible
Top or Rear Vent
3.0
76
305mm
Combustible
Mantel
152mm
Outside Air
Top Vent:
51mm
Rear Vent:
64mm
Back of Hopper:
102mm
Vent Pipe to
Combustibles:
76mm
INSTALLED AS A BUILT-IN UNIT
Shown with Rear Vent and Outside Air
Figure 10.1
Figure 10.2
AS A BUILT-IN
NOTE:
All Clearances are Minimum Clearances
Must be installed in a non-tapered enclosure.