May 12, 2014
7022-122D
Page 37
Castile Pellet Insert
F. Convection Blower Replacement
1. The blower is located at the bottom rear of the insert.
If an outside air kit is also installed, you will fi rst need
to remove the outside air fl ange by removing the 2
screws using a Phillips head screwdriver. You do not
need to remove the fl ex pipe from the fl ange.
2. If you have adequate clearance you will not have to
remove the panel set and disconnect fl ue, if not then
you will have to remove the panel set and disconnect
the fl ue.
3. Pull appliance out onto the hearth.
4. Remove left cast side.
5. Disconnect the wires from the blower. The wires
coming from the wiring harness are purple & white and
the wires from the blower are black.
6. The blower is held in place with a wing screw.
7. Re-install in reverse order.
E. Combustion Blower Replacement
1. If you have adequate clearance you will not have to
remove the panel set and disconnect fl ue, if not then
you will have to remove the panel set and disconnect
the fl ue.
2. Pull appliance out onto the hearth.
3. Remove right cast side.
4. Disconnect the white and blue wires from the blower.
5. Remove blower mounting screws (not housing bolts),
Figure 37.1
, from blower housing and remove blower.
The replacement blower is shipped with a housing.
If you do not need the housing, discard it. If you do
need to the replace the housing you will also need
to replace the gasket. See Service Parts List for the
part number.
6. Re-install in reverse order.
Figure 37.1
Housing Bolts
(Do Not Remove)
Blower
Screws