Page  4

7022-122D

May 12, 2014

Castile Pellet Insert

1

Listing and Code Approvals

A.  Appliance Certifi cation

C.  Glass Specifi cations

E.  BTU & Effi ciency Specifi cations

This appliance is equipped with 5mm ceramic glass. 

 

Replace glass only with 5mm ceramic glass.  Please contact 
your dealer for replacement glass.

This appliance is approved for mobile home installations 
when not installed in a sleeping room and when an outside 
combustion air inlet is provided.  

The structural integrity of the mobile home fl oor, ceiling, and 
walls must be maintained.  The appliance must be properly 
grounded to the frame of the mobile home and use only listed 
pellet vent, Class “L” or “PL” connector pipe.  

A Quadra-Fire Outside Air Kit must be installed in a mobile 
home installation.

B.  Mobile Home Approved

NOTE:  

This installation must conform with local codes. In 

the absence of local codes you must comply with the 

ASTM 

E1509-2004, ULC S628-93, ULC/ORD-C-1482-M1990, 
(UM) 84-HUD 

D.  Electrical Rating

115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps

MODEL:

Castile Pellet Insert-B

LABORATORY:

OMNI Test Laboratories, Inc

REPORT NO.

061-S-77d-6.2

TYPE:

Solid Fuel Room Heater/Pellet Fuel 
Burning Type Insert

STANDARD:

ASTM E1509-2004, ULC S628-93 and 
ULC/ORD-C1482-M1990 Room Heater 
Pellet Fuel Burning Type and (UM) 84-
HUD, Mobile Home Approved

NOTE:  

Hearth & Home Technologies, manufacturer of 

this appliance, reserves the right to alter its products, 
their specifi cations and/or price without notice.

WARNING! Risk of Fire! Hearth & Home Technologies dis-
claims any responsibility for, and the warranty and agency 
listing will be voided by the below actions.

DO NOT:
 

•  Install or operate damaged appliance

 • 

Modify 

appliance

 

•  Install other than as instructed by Hearth & Home 

Technologies

 

•  Operate the appliance without fully assembling all 

components

 • 

Overfi re

 

•  Install any component not approved by Hearth & 

Home Technologies

 

•  Install parts or components not Listed or approved.

 

•  Disable safety switches

Improper installation, adjustment, alteration, service or 
maintenance can cause injury or property damage. 

For assistance or additional information, consult a qualifi ed 
installer, service agency or your dealer.

Quadra-Fire is a registered trademark of Hearth & Home 
Technologies.

NOTE:  Some generator or battery back-up systems may 
not be compatible with the micro-processor electron-
ics on this appliance.  Please consult the power supply 
manufacturer for compatible systems.

The Castile Pellet Insrt by Quadra-Fire is exempt from Envi-
ronmental Protection Agency certifi cation  under 40 CFR 
60.531 y defi nition [Wood Heater (A) “Air to Fuel Ratio].

Note:

  

This appliance is also approved for installation 

into a shop.

*BTU output will vary, depending on the brand of fuel you 
use in your appliance.  Consult your Quadra-Fire dealer for 
best results.

Particulate 
Emissions Rating:

1.8 grams/hr

*BTU Output:

8,500 - 28,200 / hr

Heating Capacity:

up to 1,500 sq. ft. depending on 
climate zone

Hopper Capacity:

45 lbs

Fuel:

Wood Pellets or Shelled Corn

Shipping Weight:

214 lbs

Effi ciency

78%

These heaters meet the US Environmental Protection 
Agency’s emissions limits for pellet heaters. Under specifi c 
conditions the PS35 stove has been shown to deliver heat 
at rates ranging from 8,500 to 28,200 BTU/hr.

Summary of Contents for CASTILEI-MBK

Page 1: ...um clearances to com bustibles as specified Failure to comply may cause house fire Check building codes prior to installation Installation MUST comply with local regional state and national codes and...

Page 2: ...ervicing Replace glass only with 5mm ceramic available from your dealer To start set thermostat above room temperature the stove will light automatically To shutdown set thermostat to below room tempe...

Page 3: ...rt Standard Surround 20 21 G Surround Trim Set Econo 21 H Surround Cast Trim Set 22 I Log Set Placement 22 J Thermostat Installation 24 Section 8 Operating Instructions A Combustible Non Combustible 2...

Page 4: ...ms any responsibility for and the warranty and agency listing will be voided by the below actions DO NOT Install or operate damaged appliance Modify appliance Install other than as instructed by Heart...

Page 5: ...e the appli ance where there will be a clear passage for a factory built listed chimney through the ceiling and roof Installing an optional outside air kit would affect the loca tion of the vent termi...

Page 6: ...haust equipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces...

Page 7: ...ply most of the demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appli ance It may be necessary to add addition...

Page 8: ...meets the required minimum height 10 All labels have been removed from the glass door 11 Plated surfaces have been wiped clean if applicable 12 Thermostat or remote has been installed 13 A power outle...

Page 9: ...View Figure 9 2 Side View 819mm 707mm 594mm 203mm 483mm 629mm 249mm 330mm 51mm Overall Size A B Metal Surround w Cast Trim STD 42 1 2 in 1080mm 30 in 762mm Metal Surround w Cast Trim LRG 48 in 1219mm...

Page 10: ...ce To Exposed Section And Face Trim B Clearance To Combustibles UL and ULC Inches Millimeters A Top of Hopper Top Vent 2 0 51 Rear Vent 2 5 64 B Side of Hopper Top or Rear Vent 2 0 51 C Back of Hopper...

Page 11: ...urers instructions for installation The original factory built zero clearance fireplace chim ney cap must be re installed after installing the approved chimney liner meeting type UL 103 HT requirement...

Page 12: ...he appropriate size Ensure that the leveling bolt is positioned over the 2 x 4 before level ing the insert The fireplace must not be altered except for the exceptions listed below Do not removal the b...

Page 13: ...tions when installing venting system WARNING B Venting Termination Requirements 1 Termination must exhaust above air inlet elevation It is strongly recommended that at least 60 inches 1524mm of vertic...

Page 14: ...e vertical rise you can obtain in your system the better it will perform Horizontal vent runs can accumulate ash and will need to be cleaned more often Try to keep them as short as possible ONE 90 ELB...

Page 15: ...S ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference A Full Reline With Horizontal Outside Air Outside Air through Rear Wall Horizontal...

Page 16: ...des prior to installation Installation MUST comply with local regional state and national codes and regulations Consult local building fire officials or authorities having jurisdiction about restricti...

Page 17: ...to clearances to combustibles and floor protection requirements on pages 9 to 11 for listings to combus tibles and appropriate chimney systems 6 Use silicone to create an effective vapor barrier at t...

Page 18: ...d run pipe through wall 5 Attach hose to outside termination cap with second hose clamp 6 Secure termination cap to outside surface 7 Secure trim ring to interior wall Tools Needed Phillips head screw...

Page 19: ...ed tape that holds front and side trims to scissors has a powerful bonding adhesive Adjust ments are extremely difficult once trim has adhered to tape Do a dry run first without removing paper from ta...

Page 20: ...st Trim Footer Panel Leg 1 Remove contents from box and lay on protective surface to avoid scratching the paint 2 Lay hearth support s front and sides face down Bend the tab down toward the inside 3 T...

Page 21: ...set 5 Remove the cast sides before attaching the surround and trim Lift up the top to expose the thumb screws that secure the cast sides Remove the thumb screw and top bracket and then remove the cast...

Page 22: ...break them apart e Each clip has a clearance notch to allow room for the cast on the boss Place the clips over the boss so that the notch is facing the outer edge of the surround Figure 23 3 on page 2...

Page 23: ...ure 23 1 3 Lean the logs against the cast iron brick in the back of the firebox 4 Push the logs to the far left and far right against the sides of the firebox Figure 23 2 5 To clean the logs use a vac...

Page 24: ...cu rate readings The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air Remove any packaging from inside the thermostat before using NOTE If the th...

Page 25: ...e grain dust must be screened by sifting with 3 16 4 76mm inch mesh screening Do not use corn that contains additives such as oils or meals or has been chemically treated with pesticides It will void...

Page 26: ...on instructions 2 Double check that the ash drawer and firebox are empty 3 Close the front door CAUTION Tip of thermocouple must be in contact with the inside end of the thermocouple cover Missed igni...

Page 27: ...est setting The red call light will be on which is located on the top of the junction box behind the right access panel This indicates the thermostat is calling for heat Figure 27 1 4 The fuel feed sy...

Page 28: ...ck side of Firepot Firepot floor left open ISSUES SOLUTIONS 1 Metallic noise 1 Noise is caused by metal expanding and contracting as it heats up and cools down similar to the sound pro duced by a furn...

Page 29: ...firepot Firepot clean out plate not closed Firepot is dirty missed ignition Check that firepot clean out plate is fully closed Clean firepot Make sure there is no clinker in the firepot See page 32 Cl...

Page 30: ...g loss of vacuum Empty hopper of fuel Use a wet dry vacuum cleaner to remove remaining fuel from hopper including feed tube Check feed chute for obstructions Loosen 2 screws and jiggle feed assembly C...

Page 31: ...ick panels Change fuel brand to pre mium Check that firepot clean out plate is fully closed Reduce feed rate using feed rate adjustment control rod located inside hopper Nuisance shutdowns Low flame S...

Page 32: ...ow Cleaning or Inspection Frequency Daily Weekly Monthly Yearly Ash Pan Every 5 bags of fuel depend ing on the fuel type or ash build up OR X Ash Removal from Firebox Every 5 bags or more fre quently...

Page 33: ...bags or more frequently depending on ash build By Homeowner Locate the ash drawer underneath the firepot and slide the ash drawer straight out Empty into a non combustible container and re install ash...

Page 34: ...clear view of the firepot is obscure By Homeowner a Appliance must be completely cool before cleaning glass b Vacuum fly ash from the glass and door rope c Use a damp paper towel or any non abrasive g...

Page 35: ...Allow the appliance to completely cool down 2 Empty the hopper of any remaining pellets 3 Vacuum the hopper and feed tube 14 Preparing Firebox for Non Burn Season Frequency At the end of the heating...

Page 36: ...the firepot By Homeowner Poor quality pellet fuel or lack of maintenance can create conditions that make the firepot fill quickly with ashes and clinkers This condition makes the appliance susceptible...

Page 37: ...ss are purple white and the wires from the blower are black 6 The blower is held in place with a wing screw 7 Re install in reverse order E Combustion Blower Replacement 1 If you have adequate clearan...

Page 38: ...he igniter wires are clear of any movement i e ash drawer firepot cleaning rod cleaning slide plates etc 5 Re install the ash drawer and then re install the side panel and re connect the power 1 Open...

Page 39: ...not completely cover the top of the firebox There is an opening on the left as shown in Figure 40 5 on page 40 NOTE Improper installlation can cause poor appli ance performance Tabs Figure 39 4 Figur...

Page 40: ...2014 Castile Pellet Insert Figure 40 2 Hook on left side Tab on right side Figure 40 3 Figure 40 4 Figure 40 5 Lift brick pull forward at an angle and drop down into notches Figure 40 1 Re installing...

Page 41: ...e cover ceramic protection tube The thermocouple sends a millivolt signal to the control box indicating the preset temperatures of the green and red lights When describing the location of a component...

Page 42: ...r Call Light Snap Disc 3 Reset Button Fuse Snap Disc 1 Exhaust Blower Convection Blower Vacuum Switch Snap Disc 2 Capacitor Feed Motor Yellow Blue Gray Black Black Black Black Black White White Red Re...

Page 43: ...s Figure 43 2 Figure 43 3 RIGHT SIDE Control Box Junction Box Reset Button Heat Output Switch Power Cord Outlet Thermostat Block Fuse Red Call Light R ed G reen Am ber Light Blue Light Firepot Cleanin...

Page 44: ...rt Castile Insert B CASTILEI MBK CASTILEI PMH CASTILEI CSB CASTILEI CWL Part number list on following pages Beginning Manufacturing Date Feb 2011 Ending Manufacturing Date Active 1 2 3 4 8 9 7 6 5 10...

Page 45: ...ss Assembly Side 1 Piece 5 7 8 in W x 9 in H Interchangeable 414 5380 Y Gasket Channel 1 8 x 1 1 4 10 Ft 7000 377 10 Y 8 Backer Side Window Interchangeable 414 0280 9 Door Hinge Assembly SRV7022 012 H...

Page 46: ...16 10 Ft 240 0290 10 Y Tape Door Corner SRV7027 227 Y 23 6 Retainer Rope 7001 192 Y 24 Vacuum Switch SRV7000 531 Y 25 Corner Post SRV7022 104 26 Bolt GRD 2 Tap 3 8 x 4 223 0140 27 Snap Disc 110 20 SR...

Page 47: ...r SRV7058 148 34 Snap Disc 2 SRV7000 268 Y 35 Snap Disc Manual Reset 3 SRV230 1290 Y 36 Blower Convection 812 4900 Y 37 Feed Adjustment Plate SRV7022 119 38 1 Firepot Pull Rod Assembly 414 5270 Y Spri...

Page 48: ...CHUP CWL Power Cord 812 1180 Y Harness Thermostat Wire 230 0810 Fuse 7 Amp Junction Box Pkg of 10 812 0380 10 Y Hose Vacuum 5 32 Id 3 Ft SRV240 0450 Y Magnetic Switch 7000 375 Y Wire Harness Hopper Sw...

Page 49: ...CSTLI4834 CM Thermostat Mechanical 812 3760 Thermostat Programmable 811 0520 Trim Cast Matte Black 811 0930 Footer Left 414 7090MBK Footer Right 414 7100MBK Header 414 7110MBK Trim Leg Left 414 7120MB...

Page 50: ...apped Push 1 4 Pkg of 24 7000 157 24 Y Nut Ser Flange Small 1 4 20 Pkg of 24 226 0130 24 Y Nut Wing 8 32 Pkg of 24 226 0160 24 Y Screw Flat Head 1 4 20 Pkg of 24 7000 130 24 Y Screw 1 4 20X3 8 Phillip...

Page 51: ...May 12 2014 7022 122D Page 51 Castile Pellet Insert Date of Service Performed By Description of Service E Service And Maintenance Log...

Page 52: ...Page 52 7022 122D May 12 2014 Castile Pellet Insert Date of Service Performed By Description of Service E Service And Maintenance Log Cont d...

Page 53: ...May 12 2014 7022 122D Page 53 Castile Pellet Insert F Homeowner s Notes...

Page 54: ...the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distribut...

Page 55: ...HDWLQJ DSSOLDQFH VRPH FKDQJHV LQ FRORU RI LQWHULRU DQG H WHULRU VXUIDFH ILQLVKHV PD RFFXU 7KLV LV QRW D IODZ DQG LV QRW FRYHUHG XQGHU ZDUUDQW DPDJH WR SULQWHG SODWHG RU HQDPHOHG VXUIDFHV FDXVHG E ILQJ...

Page 56: ...e following patents United States 6830000 and 5582117 or other U S and foreign patents pending We recommend that you record the following pertinent information for your CASTILE PELLET INSERT Date purc...

Reviews: