background image

 22 

 

 

 

 

                        7022-514C 

 

 

 

 

   July 7, 2015

CASTILE INSERT

Panel Extension

Panel Leg 

Cast Trim Footer 

Figure 22.1 

F. Hearth Support (Cont’d)
Base Plate Only Installation

Parts Needed

:  (1) cast ring (2) base zero clearance panel 

extensions. Discard balance of parts.

Tools Needed:  

Phillips head screwdriver

1.  Attach base zero clearance panel extensions to cast 

ring.

2.  Place assembly under appliance.

G.  Surround & Trim Set, Econo

Included in Surround Kit:

   2 side pieces, left and right, top 

piece and fastener package.

Included in Basic Trim Kit: 

2 side pieces, left and right, top piece 

and “L” brackets.

Tools Needed:

  4-6 inch long Philips head screwdriver, 

pliers and fl at head screwdriver

1. Lay surround face down on a fl at protected surface to 

prevent  scratching.

2. Using the Philips head screwdriver attach the side 

surrounds to the top surround using 2 sheet metal screws 
provided with the kit on each side.

3.  Assemble the trim with the two corner brackets provided.

4.  Slide the assembled trim over the assembled surround 

set.

5. Remove the cast sides before attaching the surround 

and trim. Lift up the top to expose the thumb screws that 
secure the cast sides. Remove the thumb screw and top 
bracket and then remove the cast side. NOTE: The right 
cast side bracket has the hopper cut out switch attached.  
Remove the retainer from the right side and allow to 
hang down into the insert or disconnect the switch when 
removing side.

6.  Install the power cord in the surround. 

7.  If power enters the appliance on the right side:  Using 

the pliers, attach cord restraint 12 inches from the female 
end of the cord and then press into the right side panel.  

Figure 22.2.

8.  If power enters appliance on the left side: The cord will 

have to be routed through the back of the insert. When 
routing the power cord, keep cord lying fl at as possible, 
keeping the cord away from all exhaust surfaces and 
moving parts. After routing, install cord restraint and 
press into the left side panel.

9. Slide surround over the top of the insert into 

place. 

Surround attaches to bottom and top of insert sides with 
the supplies 1/4 inch screws. 

10. Plug cord into inlet on junction box routing the wire.

11. Install plug into unused hole.

Back of Top Panel

Back of Side Panel

Screws

Figure  22.3

Figure 22.2 

Figure 22.5

Thumb 
Screw

Bracke

Surround Set 
attaches to top 
and bottom of 
insert sides.

Figure 22.4

Summary of Contents for CASTILEI-MBK

Page 1: ...on in these instruc tions is not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flam mable vapors and liquids in the vicini...

Page 2: ...ensions 7 B Clearance To Combustibles UL and ULC 8 C Masonry and Zero Clearance Fireplaces 9 D Minimum Opening for Masonry and Zero Clearance Fireplaces 9 E Hearth Extension 9 F Floor Protection 9 G I...

Page 3: ...for replacement glass D Electrical Rating 115 VAC 60 Hz Start 4 1 Amps Run 1 1 Amps NOTE Some generator or battery back up systems may not be compatible with the micro processor electronics on this ap...

Page 4: ...nce and chimney will affect performance Consideration must be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to minimize the use of chimney offsets Place t...

Page 5: ...ostat Wall Control Location The thermostat wall control s location will have some affect on the appliance s operation Maximum wire length from appliance is 100 feet 30 48m continuous unspliced wire Re...

Page 6: ...ey meets the minimum height requirements Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 7 Combustible materials not installed in non combustible areas Ver...

Page 7: ...3mm 25 in 629mm 10 in 249mm 13 in 330mm 2 in 51mm A B Overall Size A B Metal Surround w Cast Trim STD 42 1 2 in 1080mm 30 in 762mm Metal Surround w Cast Trim LRG 48 in 1219mm 34 in 864mm Metal Surroun...

Page 8: ...ance To Combustibles UL and ULC Inches Millimeters A Top of Hopper Top Vent 2 0 51 Rear Vent 2 5 64 B Side of Hopper Top or Rear Vent 2 0 51 C Back of Hopper Top or Rear Vent 4 0 102 D Vent Pipe to Co...

Page 9: ...ween the masonry of the fireplace and the facing masonry E Hearth Extension If employing a hearth extension any parts or materials used in construction must be non combustible Side Wall Mantel Maximum...

Page 10: ...insert The 2 x 4 may need to be cut to the appro priate size 250 2061 WARNING THIS FIREPLACE MAY HAVE BEEN ALTERED TO ACCOMMODATE AN INSERT IT MUST BE RETURNED TO ITS ORIGINAL CONDITION BEFORE USE AS...

Page 11: ...chimney liner meeting type UL 103 HT requirements 2100 F per UL 1777 If the chimney is not listed as meeting HT requirements or if the factory built fireplace was tested prior to 1998 a full height li...

Page 12: ...protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table be...

Page 13: ...e air supply kit can supply most of the demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appli ance It may be n...

Page 14: ...mney NOTICE Hearth Home Technologies assumes no responsibility for the improper performance of the chimney system caused by Inadequate draft due to environmental conditions Downdrafts Tight sealing co...

Page 15: ...shielding or guards may be required WARNING Figure 15 2 3 in or 4 in 76mm or 102mm Diameter Pipe Equivalent Pipe Length In Feet ALTITUDE IN THOUSANDS OF FEET 0 20 30 1 2 3 4 5 6 7 8 9 10 4 in 102mm D...

Page 16: ...ting of your pellet appliance The more vertical rise you can obtain in your system the better it will perform Horizontal vent runs can accumulate ash and will need to be cleaned more often Try to keep...

Page 17: ...om Wall floor or ceiling cavity Enclosed space such as an attic or garage NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scal...

Page 18: ...er ULC S628 93 ORD ULC C1482 M1990 NOTE In Canada this fireplace insert must be installed with a continuous chimney liner extending from the fire place insert to the top of the chimney The chimney lin...

Page 19: ...asure distance from floor to air vent opening in appli ance and mark location on wall 2 Use saw to cut opening in wall Cut a 2 1 2 to 3 inch 64 76mm opening on inside wall and a 3 to 3 1 2 inch 76 89m...

Page 20: ...in your straight edge Figure 20 2 4 The double sided tape that holds front and side trims to scissors has a powerful bonding adhesive Adjustments are extremely difficult once trim has adhered to tape...

Page 21: ...de up and attach the top cast ring Figure 21 4 6 Attach the hearth support panel extensions Figure 21 5 7 Attach cast footers Figure 21 6 8 Place the assembled hearth support under the insert Figure 2...

Page 22: ...he top to expose the thumb screws that secure the cast sides Remove the thumb screw and top bracket and then remove the cast side NOTE The right cast side bracket has the hopper cut out switch attache...

Page 23: ...ng the outer edge of the surround Figure 23 3 f It is best to install all of the 1 4 20 screws only half way at first to allow for adjustments After adjustment tighten the 2 screws in each footer firs...

Page 24: ...t Instructions Two Piece Log Set Installation 1 Open door to expose the firebox 2 Install the left log first and then the right log Figure 24 1 3 Lean the logs against the cast iron brick in the back...

Page 25: ...pieces apart 2 Connect your thermostat wire to the W and R terminals see Figure 25 1 3 Screw the backer plate to the wall using the hardware included 4 Snap the thermostat to the backer plate 5 Conne...

Page 26: ...D CFR 3280 Part 24 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arestor Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 26 1 CAUTION Never draw outside combust...

Page 27: ...12 Damper 3 Inch Tall Vertical Installs Only PEL DAMP3 Y Damper 4 Inch Tall Vertical Installs Only PEL DAMP4 Log Set LOGS 30 OE Log Rear Left 7050 144 Log Rear Right 7050 143 Outside Air Kit Rear 811...

Page 28: ...2 054 Surround Standard Use With Cast Trim SP CSTLI4834 CM Thermostat WALL STAT Y Thermostat Programmable WALL STAT P Trim Cast Matte Black 811 0930 Footer Left 414 7090MBK Footer Right 414 7100MBK He...

Page 29: ...ling Bolt Pkg of 25 220 0080 25 Y Nut Capped Push 1 4 Pkg of 24 7000 157 24 Y Nut Ser Flange Small 1 4 20 Pkg of 24 226 0130 24 Y Nut Wing 8 32 Pkg of 24 226 0160 24 Y Screw Flat Head 1 4 20 Pkg of 24...

Page 30: ...30 7022 514C July 7 2015 CASTILE INSERT...

Page 31: ...July 7 2015 7022 514C 31 CASTILE INSERT...

Page 32: ...ille WA 99114 Division of HNI INDUSTRIES Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com This produc...

Reviews: