background image

7

7027-802K

10/21

This product and the fuels used to operate this product (wood), and the 

products of combustion of such fuels, can expose you to chemicals 

including carbon black, which is known to the State of California to 

cause cancer, and carbon monoxide, which is known to the State of 

California to cause birth defects or other reproductive harm. For more 

information go to: WWW.P65Warnings.ca.gov

WARNING

Improper  installation,  adjustment,  alteration,  service  or 

maintenance can cause injury or property damage.
For assistance or additional information, consult a qualified 

installer, service agency or your dealer.

D. Glass Specifications

This  appliance  is  equipped  with  5mm  ceramic  glass. 

Replace glass only with 5mm ceramic glass. Please contact 

your dealer for replacement glass.

E. Electrical Rating

115 VAC, 60 Hz, Start 3.75 Amps, Run 1.88 Amps.

F. Mobile Home Approved

•  This appliance is approved for mobile home installations 

when  not  installed  in  a  sleeping  room  and  when  an 

outside combustion air inlet is provided.

•  The structural integrity of the mobile home floor, ceiling, 

and walls must be maintained.

•  The appliance must be properly grounded to the frame 

of the mobile home and use only Listed pellet vent Class 

“L” or “PL” connector pipe.

•  Outside  Air  Kit,  part  811-0570  or  811-0872    must  be 

installed in a mobile home installation.

G. Sleeping Room

When installed in a sleeping room it is recommended that 

3ft  of  vertical  be  installed  prior  to  horizontally  exiting  the 

room and a smoke/CO alarm be installed in the bedroom. 

The size of the room must be at least 50ft³ per 1,000 Btu/hr 

stove input, if the stove exceeds the room size, outside air 

must be installed.

H. California - Prop65

NOTE: 

Hearth  &  Home  Technologies,  manufacturer  of 

this  appliance,  reserves  the  right  to  alter  its  products, 

their specifications and/or price without notice.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 

responsibility  for,  and  the  warranty  will  be 

voided by, the following actions:

•  Installation and use of any damaged appliance.

•  Modification of the appliance.

•  Installation other than as instructed by Hearth & Home 

Technologies.

•  Installation  and/or  use  of  any  component  part  not 

approved by Hearth & Home Technologies.

•  Operating  appliance  without  fully  assembling 

all components.

•  Operating appliance without legs attached (if supplied 

with appliance).

•  Do NOT Over fire - If appliance or chimney connector 

glows, you are over firing.

Any such action that may cause a fire hazard.

Summary of Contents for CB1200-C

Page 1: ...anual please contact your dealer or visit www quadrafire com REMARQUE Pour obtenir une traduction fran aise de ce manuel s il vous pla t contacter votre revendeur ou visitez www quadrafire com Tested...

Page 2: ...trictions and inspection in your area WARNING FOR MOBILE HOMES Do not install appliance in a sleeping room An outside combustion air inlet must be provided The structural integrity of the mobile home...

Page 3: ...e Safety 8 B Non Combustible Materials 8 C Combustible Materials 8 D Fuel Material and Fuel Storage 8 E Before Your First Fire 9 F Filling the Hopper 9 G General Operating Information 10 H Starting Yo...

Page 4: ...earlier However the Warranty coverage shall commence no later than 24 months following the date of Product shipment from HHT regardless of the installation or occupancy date The term Lifetime in the t...

Page 5: ...forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supplied with the applicable Product or any ot...

Page 6: ...with the requirements of CSA B415 1 Arange of BTU outputs calculated using HHV efficiency and the burn rates from the EPA tests Based on the maximum feed rate per hour multiplied by approximately 860...

Page 7: ...e properly grounded to the frame of the mobile home and use only Listed pellet vent Class L or PL connector pipe Outside Air Kit part 811 0570 or 811 0872 must be installed in a mobile home installati...

Page 8: ...d maintain regularly Conveniently locate a Class A fire extinguisher to contend with small fires In the event of a hopper fire Evacuate the house immediately Notify fire department B Non Combustible M...

Page 9: ...hat would hinder routine cleaning and maintenance Size Pellets are either 1 4 inch or 5 16 inch 6 8mm in diameter Length should be no more that 1 1 2 inches 38mm Pellet lengths can vary from lot to lo...

Page 10: ...hermostat is calling for heat 6 Once the appliance has ignited let it burn for approximately 15 minutes then set the thermostat to the desired room temperature Adjust the heat output control switch to...

Page 11: ...ld see a fire shortly If not follow Starting Your First Fire on page 10 L Restarting the Appliance Restart Process 1 When the unit has run out of fuel add pellet fuel to the hopper 2 Dump the ashes an...

Page 12: ...RCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS APPLIANCE DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL DO NOT USE CHEMICALS OR FLUIDS TO...

Page 13: ...ries from the desired set point temperature Use the UP DOWN buttons to change the number value between 1 and 9 Generally your system should cycle on about 3 to 6 times per hour A smaller differential...

Page 14: ...eatures need to be completed in a timely manner as the thermostat will time out after 10 seconds NOTE The word COPY will not appear on the display for Monday but will display each day afterwards for a...

Page 15: ...of the thermostat can be removed from the back half by using the tabs on the top edge of the thermostat housing Figure 15 2 HARDWARE RESET The hardware reset button labeled HW RST is a small round pu...

Page 16: ...enance and Service on page 17 What is the metal object with the bend in it that came inside the plastic bag It is a clean out tool used to help clean the fire pot and remove any jams in the rare event...

Page 17: ...l types OR X Top Vent Adapter More frequently depending on the fuel type or ash build up OR X Venting System More frequently depending on the fuel type OR X Follow the detailed instructions found in t...

Page 18: ...move ash with an ash vacuum or whisk broom and small dust pan d This ash is deposited in the same ash pan as the fire pot debris The ash pan should be emptied every time you clean the firebox Remember...

Page 19: ...appliance is allowed to cool has been unplugged and the exhaust blower is off b Empty the hopper of any remaining pellets c Vacuum the hopper and feed tube 6 Cleaning Heat Exchanger Chambers Drop Tub...

Page 20: ...epending on ash build up By Qualified Service Technician Homeowner Be sure the appliance is allowed to cool has been unplugged and the exhaust blower is off The products of combustion will contain sma...

Page 21: ...rom the firebox and vacuum thoroughly c Paint all exposed steel including cast iron Use the Touch Up paint supplied with the appliance or Purchase paint from your local dealer Must use a high temperat...

Page 22: ...Homeowner Poor quality pellet fuel or lack of maintenance can create conditions that make the fire pot fill quickly with ashes and clinkers This condition makes the appliance susceptible to overfilli...

Page 23: ...n fire pot Fire pot clean out plate not closed Fire pot is dirty The ignition hole between the igniter bracket and fire pot is blocked Igniter not working Control box defective Check that fire pot cle...

Page 24: ...t or does not shut off Blower not plugged in Blower is clogged with ash Blower is defective Control box is defective Check that blower is plugged into wire harness Clean exhaust system Replace blower...

Page 25: ...to housing c Re connect wiring use jumper wire if necessary Re connect power supply Remove 2 Screws Remove 4 Screws Outside Air Flex Hose Convection Blower Figure 25 2 5 5 Service Parts Replacement 2...

Page 26: ...and remove the ash drawer 2 Follow instructions to remove the ash pan found on page 18 Cleaning Ash Pan Remove the access plate directly above it by removing the 2 screws just below the ash catcher 3...

Page 27: ...frame and slightly bend up and out of the way d Slide glass out the side and slide new glass in e Re install the side glass frame and tighten the top and bottom frames f Re install the door latch if...

Page 28: ...Check the wall receptacle for 120 volt 60 Hz standard current Make sure the outlet is grounded and has the correct polarity A good surge protector is recommended 13 Red Call Light The red call light i...

Page 29: ...xchanger system is dirty or plugged or if the firebox door is open 21 Wiring Harness See Figure 29 1 below 16 Thermostat The appliance is designed to run on a 12 volt AC thermostat The heat anticipato...

Page 30: ...Tubes Figure 30 2 Power Outlet Terminal Block Center 2 screws for Thermostat Wires Figure 30 3 Figure 30 1 Heat Output Fan Speed Reset Button Call Light HIGH HIGH MED LOW LOW Outside Air Flex Hose Con...

Page 31: ...31 7027 802K 10 21 C Service and Maintenance Log Date of Service Performed By Description of Service...

Page 32: ...32 7027 802K 10 21 Date of Service Performed By Description of Service...

Page 33: ...33 7027 802K 10 21 Date of Service Performed By Description of Service...

Page 34: ...March 2019 Ending Manufacturing Date Active Classic Bay Freestanding Pellet Stove Part number list on following page 04 21 1 6 2 7 8 9 3 4 5 10 11 12 13 14 15 16 17 17 22 18 19 20 21 23 24 25 26 27 3...

Page 35: ...2 Pkg of 12 220 0490 12 Y Hopper Lid Magnetic Switch SRV7000 375 Y 2 Baffle Assembly Left 510 5350 3 Baffle Assembly Right 510 5360 4 Hinge Plate 812 4030 Hinge Door Male SRV450 2810 Screw Pan Head Ph...

Page 36: ...Loop Igniter Pkg of 1 SRV7000 462 Y Pkg of 10 SRV7000 462 10 Y Wing Thumb Screw 8 32 X 1 2 Pkg of 24 7000 223 24 Y 11 2 Combustion Plenum Trap Door 812 4100 12 Thermocouple Cover Qty 1 812 1322 Y Pkg...

Page 37: ...Y 22 Snap Disc Convection Blower 1 SRV230 0060 Y 23 Convection Blower 130 60 CFM 812 3370 Y Nut Keps Lock 8 32 Pkg of 40 226 0060 40 Y Screw Pan Head Philips 8 32 X 3 4 Pkg of 24 229 1100 24 Y 24 Snap...

Page 38: ...Assembly SRV229 0920 36 Control Board 3 Speed SRV7000 704 Y Fuse 8 Amp Control Box Pkg of 10 812 3780 10 Y 37 Cover Control Box 410 6321 38 Feed Adjustment Plate 812 4170 39 Cover Feed Motor SRV7027 0...

Page 39: ...nt 812 3570 Damper 3 Inch Tall Vertical Installs Only PEL DAMP3 Y Damper 4 Inch Tall Vertical Installs Only PEL DAMP4 Heat Exchange Repair Kit 812 4970 Log Set 811 0592 Outside Air Kit Floor 811 0570...

Page 40: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...