R
May 6, 2015
7014-179K
Page 17
CB 1200 Pellet Stove
Fire Hazard
Inspection of Chimney:
•
Masonry chimney must be in good condition.
•
Meets minimum standard of NFPA 211
• Factory-built chimney must be minimum 6 in. (152mm)
UL103 HT.
WARNING
F. Masonry
G. Alternate Masonry
Non-Combustible Hearth Pad
Airtight
Clean-out Door
Cleanout Cover
Sheathing
3 in. (76mm) Minimum
1 in. (25mm) Clearance
Flashing
Fireclay Flue
Liner with Airspace
Concrete Cap
1 in. (25mm) Clearance
with Firestop
6 in. (152mm)
Minimum
Non-Combustible Hearth Pad
Sheathing
2 in. (51mm) Minimum
1 in. (25mm)
Clearance
Flashing
Fireclay Flue Liner
with Airspace
Concrete Cap
6 in. (152mm)
Minimum
Airtight Clean-out Door
1 in. (25mm) Clearance
with Firestop
Figure 17.1
Figure 17.2
Summary of Contents for CB1200M-MBK