Page 32
7014-179K
May 6, 2015
R
CB 1200 Pellet Stove
7. Cleaning Beneath Heat Exchanger
• Frequency:
Monthly or after burning 1 ton of fuel
• By:
Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
b. A more thorough cleaning is needed to remove the
excess ash that is left behind from the use of the cleaning
rods for the heat exchanger tubes.
c. The ash will be resting on the back of the baffl es.
This will require removing the baffl es. Please refer to
page 33
for instructions on removing the baffl es.
8. Cleaning Exhaust Path
• Frequency:
Yearly or more frequently depending on
ash build-up.
• By:
Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
b.
Remove access door on the right of the appliance (4
screws).
c.
Use a small vacuum hose attachment to clean area.
d.
Re-install and close trap door.
NOTE: There are heavy duty vacuum cleaners specifi cally
designed for solid fuel appliance cleaning.
9. Cleaning the Glass
• Frequency:
When clear view of the fi repot becomes
obscure.
• By:
Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Use a damp paper towel or any nonabrasive glass
cleaner. Wipe off with dry towel.
Handle glass assembly with care.
When cleaning glass:
• Avoid striking, scratching or slamming
glass.
CAUTION
• Do NOT clean glass when it is hot.
• Do NOT use abrasive cleaners.
• Use a hard water deposit glass cleaner on white fi lm.
• Refer to maintenance instructions.
10. Door Latch Inspection
• Frequency:
Prior to heating season
• By:
Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
b. To adjust, open the latch and pivot the holding rod out.
Loosen the jam nut on the rod.
c. With a Phillips head screw driver, turn the rod clockwise
to tighten. The latch handle should snap securely in place
when adjusted properly.
d. After adjusting the latch, be sure to tighten the jam nut
on the rod to hold the adjustment.
11. Door Gasket Inspection
• Frequency:
Prior to heating season
• By:
Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
b. To inspect the door rope (gasket), open the door and
see that the door rope extends approximately 1/8 inch
(3mm) to 3/16 inch (9.5mm) from the door rope channel.
c. It should show signs of compaction all the way around
the door where the rope contacts the face of the appliance.
Confi rm there are no air leaks.
12. Cleaning the Hopper
• Frequency:
Monthly or after burning 1 ton of fuel
• By:
Homeowner
After burning approximately 1 ton of fuel or changing fuels
you will need to clean the hopper to prevent sawdust build-
up.
A combination of sawdust and pellets on the auger reduces
the amount of fuel supply to the fi repot. This can result in
nuisance shutdowns and mis-starts.
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b
Empty the hopper of any remaining pellets.
c.
Vacuum the hopper and feed tube.
13. Cleaning Exhaust Blower - Requires No Lubri-
cation
• Frequency:
Yearly or as needed
• By:
Quality Service Technician/Homeowner
• Task:
Contact your local dealer.
14. Cleaning Convection Blower - Requires No
Lubrication
• Frequency:
Yearly or as needed
• By:
Qualifi ed Service Technician
•
Task: Contact your local dealer.
Summary of Contents for CB1200M-MBK
Page 47: ...R May 6 2015 7014 179K Page 47 CB 1200 Pellet Stove E Warranty Policy...
Page 48: ...Page 48 7014 179K May 6 2015 R CB 1200 Pellet Stove...
Page 49: ...R May 6 2015 7014 179K Page 49 CB 1200 Pellet Stove...
Page 50: ...Page 50 7014 179K May 6 2015 R CB 1200 Pellet Stove...
Page 51: ...R May 6 2015 7014 179K Page 51 CB 1200 Pellet Stove...