11
June 4, 2019
7027-801C
CB1200 Free Standing
USA INSTALLATIONS
: A
non-combustible floor protection
is recommended extending beneath the flue pipe when
installed with horizontal venting or under the Top Vent
Adapter with vertical installation.
CANADA INSTALLATIONS
: A non-c
ombustible floor
protection
extending beneath the flue pipe
is
required
with horizontal venting or under the Top Vent Adapter with
vertical installation.
33-1/2 in.
minimum
30-3/4 in.
minimum
6 in
(FROM SURFACE OF
GLASS)
6 in
USA
21-1/2 in.
minimum
850mm
minimum
781mm
minimum
152mm
(FROM SURFACE OF
GLASS)
152mm
545mm
minimum
Must extend 51mm
beyond each side
of pipe (shaded area)
to the wall thimble.
CANADA
47-3/4 in.
26-1/4 in.
21-1/2 in.
41-3/8 in.
6 in.
from the fuel door
opening
USA
1214mm
666mm
545mm
1051mm
152mm
(front door opening)
CANADA
Must extend 51mm
beyond each side
of pipe (shaded area)
to the wall thimble.
Figure 11.1
Figure 11.2
Figure 11.3
Figure 11.4
EMBER PROTECTION:
It is necessary to install a Type I
floor protector.
Floor protector must be non-combustible material,
extending beneath appliance with a minimum of 6 inches
(152mm) in front of glass and 6 inches (152mm) to both
sides of the fuel loading door. Open the door and measure
6 inches (152mm) from the side edge of the opening in the
face of the appliance.
*See exception
.
C. Hearth Pad Requirements (UL and ULC)
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
Failure to comply may cause house fire.
WARNING