Appliance Set-Up
A. Outside Air Kit Instructions
Included in Kit:
1 piece of 2 inch x 3 foot flex hose, 2 hose
clamps, 1 collar assembly, termination cap assembly, 1 trim
ring, 12 screws.
Tools Needed:
Phillips head screw driver; wire cutters;
hole saw or jig saw.
1. Rear Installation
a.
Measure distance from floor to air vent opening in
appliance and mark location on wall.
b. Use saw to cut opening in wall. Cut a 2-1/2 to 3
inch (64-76mm) opening on inside wall and a 3 to
3-1/2 inch (76-89mm) opening on outside of house.
c.
Use hose clamp to secure flex pipe to
collar assembly.
d.
Slide trim ring over flex pipe and run pipe
through wall.
e. Attach hose to outside termination cap with second
hose clamp.
f. Secure termination cap to outside surface.
g. Secure trim ring to interior wall.
h. Snip corners and remove plate
(Figure 20.1)
.
i. Align and secure collar assembly with 2 of the 4
holes as shown
(Figure 20.2)
.
Flex Hose
Hose Clamp
Collar Assembly
Trim Ring
Termination
Cap Assembly
Hose Clamp
Air Intake Channel
(Discard)
Figure 20.2
Figure 20.1
Snip Corners
and remove
plate
NO
NO
Secure Collar
Screen
Install Cover Plate
Seal Pedestal with 26 in. Rope
Figure 20.4
Figure 20.3
2. Floor Installation
a. Remove rear screen and set aside.
b.
Install cover plate over hole in right rear floor.
c.
Cut a 2 inch minimum hole in the floor to
accommodate flex hose.
d. Attach hose to termination cap.
e.
Place rope under pedestal to close off air leaks.
CAUTION
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity.
• Enclosed space such as an attic or garage.