background image

Page  4

7014-145

May 9, 2008

Tools Needed: 

Shop Vac and Phillips head screwdriver

1200 Pellet Stove

1. 

Lift the hopper lid to access the cleaning rods.  Both 

black bent handle pull rods are located close to the face 

of the appliance to the left and right side.  

Figure 4.1.

2. 

Pull the rods straight out until they stop, approximately 

0 inches (508mm). 

 

.  To clean, slide the rods OUT and IN a couple of times.

A. Cleaning the Heat Exchanger Chambers

Heat Exchanger Cleaning Rods

Figure 4.1

1.  Open the upper right side panel door and then open 

the glass door.

.  The    baffles  are  located  at  the  top  inside  of  fire

-

box.

.  Place your hand on the baffle and slide it up and the 

bottom edge will fall down and then you can lift the 

baffle out.  Repeat for the other side.

4.  Re-install in reverse order.

B.  Remove Baffle to Access Heat Exchanger 

Tubes and Firebox Exhaust Exits

Exposed Heat Exchanger Tubes

Drop Tube

1. 

Use a Shop Vac to vacuum any fly ash and soot from the 

heat exchanger tubes and firebox area.  

Figure 4.2

.

.  Remove any debris that may be in the drop tube.

C.  Vacuum Heat Exchanger Tubes, Firebox Area 

and Drop Tube

Figure 4.2

D.  Clean Exhaust Exit Behind the Exhaust Blower 

1.  Open  both  the  upper  and  lower  right  side  panels.

Figure 4.3

.

.  Using a Phillips head screwdriver remove the 4 screws 

from the clean-out plate and set aside. 

 Figure 4.3. 

.  Use a small vacuum hose attachment to clean area.  

Figure 4.4

.

4.  Re-attach clean-out plate and close side panels.

Clean-Out Plate Removed

Exhaust Blower

Clean-Out Plate

Remove 4 Screws

Open Right 

Side Panels

Figure 4.3

Figure 4.4

Reviews: