R
December 6, 2011
7051-158B
Page 11
EDGE 60 Pellet Fireplace
2. Soft Start Cycle (SS-Low / SS-Med)
Once the fi re is lit:
• The appliance moves into the low soft-start cycle as it
continues to build the fi re
• More fuel will be added
• As the fi re builds, the appliance will change to medium
soft-start mode
• The heating cycle begins
3. Heating Cycle ( Auto / Man - L, ML, M, MH, H)
There are two choices in the Automatic / Manual menu of
how your appliance will operate:
Automatic Mode
• The wall control will turn the heat output level up or down
depending on how far the room temperature is from the
desired temperature
• The digital display will read AUTO:M, i.e. automatic-me-
dium level
• As the room temperature approaches the desired tem-
perature, the appliance will turn down to lower settings
• When the home reaches your set temperature, the appli-
ance will go into the shutdown cycle
Manual Mode
• Set the heat output setting from the main screen
• The right bottom button will read HEAT OUTPUT
• You can operate the appliance from any of the 5 levels
• On the lowest level (MAN: L) the appliance will stay on
longer, burn less fuel per hour, and will take longer to
bring the home up to your desired temperature
• On the highest setting (MAN:H) the appliance will burn
more fuel per hour, and bring your home up to tempera-
ture more quickly
• In Manual mode the heat output does not change but
will stay at the setting you chose until the comfort level
is reached (meaning the thermostat has been satisfi ed).
Turn to OFF to stop operation.
4. Shutdown Cycle
Once your home has reached your set temperature:
• Appliance will stop feeding fuel and allow the fi re to dimin-
ish
• Convection blower will continue to run until the appliance
cools to appropriate temperature
• Appliance will begin the auto-clean cycle
5. Auto-Clean Cycle
The fi repot auto-clean system will cycle:
• When the appliance is fi rst plugged in
• When the house reaches temperature and the appliance
shuts down
• At prescribed intervals, depending on the type of fuel se-
lected
• When starting up after an electrical interruption
If your appliance is running and the auto-clean cycle is initi-
ated, the appliance will revert to shutdown cycle.
• The fl oor of the fi repot will open and dump the ash into
the ash pan
• It takes approximately 2 minutes to complete the auto-
clean cycle
• The fl oor will then shut, and if the thermostat is still call-
ing for heat, the fi re will start again
• During this auto-clean cycle, the convection blower may
continue to run. The combustion blower will continue to
run.
Additional Screen Messages:
READY
It is telling you that the home is up to temperature
and doesn’t need any heat.
- - - - -
The screen will show 5 dashes when the wall
control and the control board are NOT communicating with
each other. Check that the wiring on the thermostat is prop-
erly connected.
MAINTENANCE BURN
This indicates the appliance is
operating on battery backup, prior to the auto-clean. The
maintenance burn will keep the system from shutting down
as the appliance will not automatically re-light in battery
back-up mode.
OFF
The AUTO/MANUAL SETTING screen has been set
to OFF. Set the appliance to OFF when performing periodic
maintenance to prevent an unexpected startup.
BLANK SCREEN
The ON/OFF switch may in OFF posi-
tion. Turn to ON position.
Tested and approved for wood pellets, shelled fi eld
corn, wheat and black oil sunfl ower seeds. Burning
of any other type of fuel voids your warranty.
CAUTION