R
December 6, 2011
7051-158B
Page 41
EDGE 60 Pellet Fireplace
E. Chimney and Exhaust Connection
1.
Chimney & Connector
: Use 3 or 4 inch (76-102mm)
diameter type "L" or "PL" venting system. It can be vented
vertically or horizontally.
2. Mobile Home:
Approved for all Listed pellet vent. As
with all installations a Quadra-Fire Outside Air Kit must
be used with manufactured home installations.
3
. INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
4. Exhaust Venting
System
: Secure to the appliance with
at least 2 screws 180 degrees apart. Also secure all
connector pipe joints with at least 3 screws through each
joint.
NOTE: All pipe must be welded seam pipe whenever
possible. Seal pipe joints with high temperature silicone
(500°F [260°C] minimum rated only).
NOTE: If burning shelled fi eld corn, you must use
approved venting specifi cally designed for corn. Follow
the instructions from the venting manufacturer.
• Only LISTED venting components may be used.
• NO OTHER vent components may be used.
• Substitute or damaged vent components may impair
safe operation.
WARNING! RISK OF FIRE!
WARNING! RISK OF INJURY OR PROPERTY
DAMAGE!
• Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
• Refer to the owner’s information manual provided with this
appliance.
• For assistance or additional information consult a qualifi ed
installer, service agency or your dealer.
The table below can help you calculate the equivalent feet
of pipe which is a method used to determine pellet vent size.
Figure 40.1.
F. Equivalent Feet of Pipe
Figure 40.1
2 ft.
2 ft.
3 ft.
2 ft.
Example of 3 Elbow-Rear Vent Termination Calculation
Pellet Venting
Component
# of
Elbows
Feet of
Pipe
Multiplied
By
Equivalent
Feet
Components
Equivalent Feet
90
o
Elbow or Tee
3
X
5
15
45
o
Elbow
X
3
Horizontal Pipe
7
X
1
7
Vertical Pipe
2
X
0.5
1
Total Equivalent Feet
23
Note: This is a generic example and is not
intended to represent any specifi c fuel type.
Vent surfaces get HOT, can cause burns
if touched. Non-combustible shielding or
guards may be required.
WARNING
CAUTION!
•
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
•
DO NOT INSTALL A FLUE DAMPER IN THE EX-
HAUST VENTING SYSTEM OF THIS UNIT.