Page 44
7051-158
April 9, 2009
R
EDGE 60 Pellet Fireplace
R
R
Non-combustible
Hearth Extension
Clean-out
Cover
Tee
Wall Thimble
Support
Bracket
every 60 in.
(1524mm)
12 in.
(305mm)
minimum
Termination
Cap
Flashing
0 in. (0mm) to Standoff
6 in. (152mm)
minimum
Firestop
Flashing
Termination
Cap
6 in.
(152mm)
Min.
Non-combustible
Hearth Extension
1 in. (25mm)
Minimum
*See Note
12 in.
(305mm)
Minimum
0 in. (0mm) to
Standoff
J. Vertical - Interior - Typical Installation
K. Through the Wall & Vertical - Exterior
Figure 44.1
Figure 44.2
We recommend a minimum of 60 inches (154mm)
vertical, however above the eave is preferred.
Both installations are approved for mobile home instal
-
lations. Must use or 4 inch (76 to 10mm) “L” or
“PL” Listed pellet venting or Listed double wall pipe
and Quadra-Fire Outside Air Kit in all installations.
Single wall pipe is approved for residential installa
-
tions only.
*NOTE:
Clearance to combustibles are for 1 inch
(5mm) clearance approved pellet pipe. If pellet pipe
has a inch or inch (51mm or 76mm) air clearance
to combustibles, increase the clearance from rear
standoff accordingly to meet pipe manufacturer clear
-
ance requirements