Page 46
7051-158
April 9, 2009
R
EDGE 60 Pellet Fireplace
R
R
. The appliance must be secured to the mobile home
structure by bolting it to the floor (using lag bolts). Use
the same holes that secured the appliance to the ship
-
ping pallet. See
page 33
for detailed instructions.
4. The appliance must be grounded with #8 solid copper
grounding wire or equivalent, terminated at each end
with an NEC approved grounding device.
5. Refer to Clearances to Combustibles and floor protec
-
tion requirements on
Section 6
for listings to combus
-
tibles and appropriate chimney systems.
6. Use silicone to create an effective vapor barrier at
the location where the chimney or other component
penetrates to the the exterior of the structure.
7. Follow the chimney manufacturer’s instructions when
installing the vent system for use in a mobile home.
8.
I
nstallation shall be in accordance with the Manufacturers
Home & Safety Standard (HUD) CFR 80, Part 4.
SparkArrestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Appr
ove
d Cla
ss L
o
r
PL Pe
ll
et Vent
Figure 46.1
9
Mobile Home Installation
WARNING! Risk of Asphyxiation!
•
Never install in a sleeping room.
Consumes oxygen in the the room.
CAUTION!
Maintain the structural integrity of the floor, wall,
ceiling and/or roof of the mobile home:
Do
NOT
cut through:
• Floor joist, wall, studs or ceiling trusses.
• Any supporting material that would affect the structural
integrity.
•
Remain clear of leaves, debris, ice and/or snow.
• Be unrestricted while the appliance is in use to pre
-
vent room air starvation which causes smoke spill
-
age.
•
Smoke spillage can also set off smoke alarms.
1.
An outside air intake must be provided for the combus
-
tion air and must:
. The combustion air duct system must be made of metal
and it must:
•
Permit zero clearance to combustible construction.
• Prevent material from dropping into the inlet or into
the area beneath the dwelling.
• Must contain a rodent screen.