B. Hearth Protection Requirements
FLOOR PROTECTION: It is necessary to install a Type
II floor protector.
Floor protector must be non-combustible material of a min-
imum of 3/8 inch (10mm) thick, with a minimum R value of
1.06 extending under the appliance to a minimum of 16 inches
(406mm) in front of glass, and 8 inches (203mm) to both
sides of the fuel loading door. Open the door and measure
8 inches (203mm) from the side edge of the opening in the
face of the appliance. *
See exception.
In Canada,
similar floor protection must be provided 18 inches
(457mm) in front and 8 inches (203mm) from the sides and
rear of the appliance.
Figure 8.2
*EXCEPTION:
Non-combustible floor protections must
extend beneath the flue pipe when installed with horizontal
venting and extend 2 inches (51mm) beyond each side.
See
Figure 8.4
WARNING
Fire Risk
Hearth pads must be installed exactly as specified.
High temperatures or hot embers may ignite concealed
combustibles.
60-7/8
in.
36-1/4
in.
19-1/8
in.
49-3/4
in.
16
in.
(front door opening)
USA
Figure 8.4
Corner hearth pad dimensions with single wall pipe
Corner hearth pad dimensions with double wall pipe
1594
mm
956
mm
486mm
1295
mm
457mm
(front door opening)
CANADA
1507
mm
895
mm
486
mm
1237
mm
457mm
(front door opening)
CANADA
Figure 8.5
Figure 8.6