13
17 August, 2018
7075-177A
VOYAGEUR GRAND AU
D. Venting Systems
Chimney Connector:
It is also known as flue pipe or stove pipe. It must be
152mm minimum diameter stainless steel connector pipe.
Chimney:
The chimney can be new or existing, masonry or
prefabricated and must meet the following minimum
requirements as specified below.
E. Inspections
Existing chimneys should be inspected and cleaned by a
qualified professional prior to installation. The chimney must
not have cracks, loose mortar or other signs of deterioration
and blockage. Hearth & Home recommends a certified pro-
fessional or a technician, under the direction of a certified
professional.
F. Larger Chimneys
Hearth & Home recommended that chimneys with larger
diameters than 152mm be fully relined. An oversized flue
can affect draft and impair performance and will allow
increased build-up of creosote.
WARNING
Risk of Fire!
Follow venting manufacturer’s clearances and
instructions when installing venting system.
Fire Risk.
Inspection of Chimney:
•
Chimney must be in good condition.
•
Factory-built chimney must be 152mm.
WARNING
NOTICE:
Check with your local building authorities.