REVERSIBLE FLUE COLLAR
The flue collar is reversible for either a top or rear venting
installation. The unit is shipped with the flue collar in the top
vent position.
CONVERTING COLLAR FOR REAR VENT INSTALLATION
1. Remove 5 Phillips head screws from the rear shield, lift
shield up and set aside.
2. Remove bolts from each side of the flue transition (2
total). (Place your free hand in flue opening to locate
and retrieve nuts attached to bolts.)
3. Turn vent to horizontal position. Inspect sealant to ensure
a leak free application.
4. Re-assemble in reverse order.
Mounting Screws
Bend Flange Down
Please note this cover plate will not
work with the Low-Profile Kit
REAR FLUE DEFLECTOR COVER PLATE
This cover plate is used when the flue collar is turned for a
rear vent application.
2. Bend the cover plate flange down.
3. Secure the cover plate with the remaining two screws.
1. After the flue collar has been reversed for a rear vent
installation, install the cover plate on the stove with the