MT VERNON-AE TROUBLE SHOOTING MANUAL
7020-057D
9-30-2010
8:
THE FIREPOT THERMO-
COUPLE STARTS READING
THE TEMPERATURE RISE
AND THE UNIT WILL GO INTO
“SOFT-START LOW”.
OPERATION CHART
PAGE 4
12:
THE DROP TUBE
THERMOCOUPLE WILL
BEGIN READING TEMPERA-
TURE. 105 DEGREES WILL
BE NEEDED TO TURN THE
CONVECTION BLOWER ON.
13:
AS THE TEMPERATURE
RISES, THE CONVECTION
BLOWER WILL INCREASE IN
SPEED.
11:
SOFT-START MEDIUM
WILL DISPLAY AFTER SOFT
START LOW HAS EXPIRED.
THE LENGTH OF THIS MODE
WILL VARY DEPENDING ON
THE FUEL SELECTED.
9:
SOFT-START LOW IS A
TIMED MODE AND WILL VARY
IN LENGTH DEPENDING ON
THE FUEL TABLE SELECTED.
SOFT-START LOW TIMES: (REV 3)___________(REV 4)
SOFTWOOD......................4 MINUTES...............4 MINUTES
HARDWOOD.....................4 MINUTES...............4 MINUTES
UTILITY..............................4 MINUTES...............4 MINUTES
CORN................................12 MINUTES.............10 MINUTES
WHEAT...............................9 MINUTES..............9 MINUTES
SUNFLOWER SEEDS.......4 MINUTES...............4 MINUTES
10:
THE IGNITER WILL SHUT
OFF AFTER SS LOW EXPIRES
FOR FUEL TABLE REV 2 & 3. REV
4 WILL SHUT OFF AFTER START-
UP EXPIRES.
(PELLET ONLY)
SOFT-START MEDIUM TIMES: (REV 3) (REV 4)
SOFTWOOD......................5 MINUTES.............5 MINUTES
HARDWOOD.....................5 MINUTES..............5 MINUTES
UTILITY..............................5 MINUTES..............5 MINUTES
CORN................................12 MINUTES............10 MINUTES
WHEAT...............................8 MINUTES..............8 MINUTES
SUNFLOWER SEEDS.......5 MINUTES..............5 MINUTES
NORMAL SETTING:
135 DEGREES TO REACH MAX SPEED.
QUIET SETTING:
165 DEGREES TO REACH MAX SPEED