F. Programmable Wall Thermostat Installation
The appliance comes standard with a wall thermostat and 25’
of wire. If you need to run more than 25’ make sure you use
a continuous strand of 18 to 22 gauge thermostat wire. For
optimum performance your thermostat should be located on
an inside wall approximately 5’ up from the floor.
How to Install Your Programmable Wall Ther-
mostat
1. Separate the body of the thermostat from the mounting
plate by gently pulling the two pieces apart
2. Connect your thermostat wire to the W and R terminals
(see figure below)
3. Screw the backer plate to the wall using the hardware
included
4. Snap the thermostat to the backer plate
5. Connect the wires to the 2 center screws on the terminal
block on the back of the product
Figure 23.1
Figure 23.3
There is a 4 screw terminal block located on the back lower
left corner of the appliance directly above the power cord inlet.
The center 2 screws are for the thermostat wires.
Figure 23.2
Programming Thermostat
The thermostat maintains a desired room temperature. The
5-2 day programmable function allows one program for week
days and a separate program for Saturday/Sunday. (Up to
4 periods per day).
Thermostat Controls
Saturday and Sunday can be programmed individually
by changing the format from 5-2 to 5-1-1. To change
the format :
1. Press and hold the up button and the center button
until the display changes.
2. Press up or down to change system function number
to 16.
3. Press
NEXT
to advance to next function.
4. Press up or down to change status number to 1.
5. Press
DONE
to exit and save settings.
Function buttons
Press to select the function
displayed just above each
button. (Functions change
depending on the task.)
Digital display
Temperature buttons
Press up or down to set preferred
temperature.
Hold Button
Press to override
programed tem-
perature control