background image

October 12, 2017 

 

 

 

           7080-162B 

 

 

 

         

                  3

MT VERNON E2-C

The Quadra-Fire Mt. Vernon E2 Pellet Appliance meets the U.S. 

ENVIRONMENTAL PROTECTION AGENCY 

Certified  to  comply 

with 2020 particulate emission standards at 0.74 G/HR EPA CFR 

subpart AAA, using ASTM E2779-10, ASTM 2515-11 Method- 
Pellet Appliance sections, CSA B415.1-10

This pellet  appliance 

needs periodic inspection and repair for proper operation. It 

is against federal regulations to operate this pellet appliance 

in a manner inconsistent with the operating instructions in 

the owner’s manual.

Emissions Report Number: 0061PS094E

EPA Certification #:

98-17

EPA Certified Emissions:

0.74 g/hr

*LHV Tested Efficiency:

83.2%

**HHV Tested Efficiency:

77.9%

***EPA BTU Output: 12,682 - 39,428 / HR

****BTU Input: 16,396 - 50,775 / HR

Vent Size: 3 or 4, “L” or “PL”

Hopper Capacity: 80 lbs.

Fuel Wood Pellets

* Weighted average LHV efficiency using data collected during 

EPA emissions test.

**

Weighted average HHV efficiency using data collected during 

EPA emissions test.

***

A range of BTU outputs based on HHV and the burn rates from 

the low and high EPA tests.

****

Based on the maximum feed rate per hour multiplied by 

approximately 8600 BTU’s which is the average BTU’s from a 

pound of pellets.

Important Safety Information

NOTE:  Hearth & Home Technologies, manufacturer of this appli-

ance, reserves the right to alter its products, their specifications 

and/or price without notice.

Improper installation, adjustment, alteration, service or maintenance 

can cause injury or property damage. 

For assistance or additional information, consult a qualified installer, 

service agency or your dealer.

•  Installation and use of any damaged appliance. 

•  Modification of the appliance.

•  Installation other than as instructed by Hearth & Home 

Technologies.

•  Installation and/or use of any component part not approved by 

Hearth & Home Technologies.

•  Operating appliance without fully assembling all components.
•  Operating appliance without legs attached (if supplied with 

appliance).

•  Do NOT Over fire - If appliance or chimney connector glows, 

you are over firing.

Any such action that may cause a fire hazard.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty will be voided by, 

the following actions: 

C. Glass Specifications

This appliance is equipped with 5mm ceramic glass.  

Replace glass only with 5mm ceramic glass.  Please con-

tact your dealer for replacement glass.

Model

Mt. Vernon Pellet Appliance E2

Laboratory

OMNI Test Laboratories, Inc.

Report No.

061-S-83-2

Type

Solid Fuel Room Appliance, Pellet Fuel Burn-
ing Type

Standard

ASTM E1509-12, ULC S627-00 and (UM) 

84-HUD, Mobile Home Approved.

FCC

Complies with Part 15 of FCC Rules. Opera-

tion is subject to the following two conditions:  

(1) this device may not cause harmful inter-

ference, and (2) this device must accept any 

interference received, including interference 

that may cause undesired  operation.

A. Appliance Certification

NOTICE:  

This installation must conform with local codes. In the 

absence of local codes you must comply with the 

ASTM E1509-

12, ULC S627-00, (UM) 84-HUD and  ULC/ORD-C-1482. 

B. BTU & Efficiency Specifications

D. Electrical Rating

115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps

E. Mobile Home Approved

 • 

This appliance is approved for mobile home installa-

tions when not installed in a sleeping room and when 

an outside combustion air inlet is provided.

 • 

The structural integrity of the mobile home floor, ceil

-

ing, and walls must be maintained.  

 • 

The appliance must be properly grounded to the 

frame of the mobile home and use only Listed pellet 

vent Class “L” or “PL” connector pipe.  

 • 

Outside Air Kit, part OAK-3 must be installed in a mo-

bile home installation.

F.  Non-Combustible Materials

Material which will not ignite and burn, composed of any 

combination of the following: 

  - Steel 

- Plaster  

- Brick 

- Iron 

  - Concrete  - Tile 

- Glass 

- Slate

Materials reported as passing 

ASTM E 136, Standard 

Test Method for Behavior of Metals, in a Vertical Tube 

Furnace of 750° C. 

G. Combustible Materials

Material made of/or surfaced with any of the following 

materials: 

 

- Wood  

 

- Compressed Paper

 

- Plant Fibers   

- Plastic

 

- Plywood/OSB   

- Sheet Rock (drywall)

Any material that can ignite and burn: flame proofed or not, 

plastered or non-plastered. 

Summary of Contents for MT VERNON E2-C

Page 1: ...y or death Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firi...

Page 2: ...B Tools And Supplies Needed 5 C Inspect Appliance and Components 5 D Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Clearances to Combustibles US Canada 10 C Hearth Pad...

Page 3: ...or chimney connector glows you are over firing Any such action that may cause a fire hazard WARNING Fire Risk Hearth Home Technologies disclaims any responsibility for and the warranty will be voided...

Page 4: ...installation Location of the appliance and chimney will affect performance Consideration must be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to minimiz...

Page 5: ...lasses Framing Square Electric Drill Bits 1 4 Level May also need Vent Support Straps Venting Paint Tools and building supplies normally required for installation unless installing into an existing ma...

Page 6: ...checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the appliance Check outlet w...

Page 7: ...1 8 in 155mm 6 1 8 in 155mm 14 in 357mm q q 5 13 16 in 147mm 2 9 16 in 65mm 3 13 16 in 97mm 14 1 16 in 357mm Figure 7 2 Top View with Top Vent Adapter TPVNT 3 and Offset Adapter 811 0720 Figure 7 4 To...

Page 8: ...e View Figure 8 4 Side View with Top Vent Adapter TPVNT 3 and Offset Adapter 811 0720 Figure 8 2 Front View 28 1 8 in 714mm 32 in 813mm 11 3 4 in 297mm 18 1 2 in 469mm 28 7 16 in 722mm Figure 8 1 Top...

Page 9: ...PVNT 3 and Offset Adapter 812 3570 Figure 9 2 Side View with Top Vent Adapter TPVNT 6 and Offset Adapter 812 3570 Figure 9 3 Side View with Top Vent Adapter TPVNT 6 and Offset Adapter 811 0720 25 1 2...

Page 10: ...ck Wall to Appliance 8 203 Installations with TPVNT 3 Top Vent Adapter with Heat Shield and Clean out TPVNT 6 Top Vent Adapter with Clean out 811 0720 3 to 4 Offset Adapter 812 3570 3 to 6 Offset Adap...

Page 11: ...area to the wall thimble 152mm 152mm FUEL DOOR OPENING 514mm minimum 44 1 8 in 22 5 8 in 24 1 4 in 39 3 4 in USA 6 in from the fuel door opening 1121mm 575mm 616mm 1010mm 152mm front door opening CANA...

Page 12: ...llustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference D Alcove Figure 12 1 All minimums listed are to a combustible surface Minimum Maximum Inch...

Page 13: ...paved driveway located on public property M 12 in Under an open veranda porch deck or balcony N See Note below Electric service above below or to the side location must not obstruct or interfere with...

Page 14: ...demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appli ance It may be necessary to add additional ventilation...

Page 15: ...ly or horizontally 2 Mobile Home Approved for all Listed pellet vent If using the 3 inch 76mm vertical Top Vent Adapter Kit or the 3 to 6 inch 76 152mm Top Vent Offset Adapter use Listed double wall f...

Page 16: ...you may use 3 or 4 inch 76 to 102mm diameter type L or PL vent G Pipe Selection Chart The chart will help you in determining proper venting size according to the equivalent feet of pipe calculated pr...

Page 17: ...mm Minimum 2 in 51mm Minimum 6 in 152mm Minimum 6 in 152mm Minimum 45 Degree 5 Venting Systems A Through The Wall Horizontal termination cap must be a minimum of 6 inches 152mm from the wall Approved...

Page 18: ...stop Non combustible Hearth Pad 12 in 305 mm Minimum Rain Cap Flashing 3 in 76mm Min 6 in 152mm Min 3 to 3 in 76 to 76mm Top Vent Kit Clean out Cover Figure 18 3 All three installations are approved f...

Page 19: ...5mm clearance with firestop Figure 19 1 Figure 19 2 Concrete Cap Non combustible Hearth Pad 6 in 152mm Min Airtight clean out door Sheathing 1 in 25mm clearnance Flashing Fireclay Flue Liner with airs...

Page 20: ...T INCLUDED Tools Needed Phillips head screw driver wire cutters hole saw or jig saw 1 Measure distance from floor to air vent opening in appli ance and mark location on wall Use saw to cut opening in...

Page 21: ...4 Install the 5 mounting screws 3 on the left and 2 on the right 5 Drill 2 holes with 26 drill bit through the rear exhaust outlet using the 2 holes already in the short horizontal pipe in the top ven...

Page 22: ...e appliance warranty Figure 22 1 Log fits over screws Left Log Log has indentations on the bottom to fit over the screw heads Log rests in front of screws Right Log Figure 22 3 Figure 22 4 E Optional...

Page 23: ...terminal block located on the back lower left corner of the appliance directly above the power cord inlet The center 2 screws are for the thermostat wires Figure 23 2 Programming Thermostat The thermo...

Page 24: ...e next time period Leave Repeat steps 2 and 3 for each weekday time period 5 Press NEXT to set weekend time periods Sat Sun then press DONE to save exit NOTE You can press CANCEL PERIOD to eliminate u...

Page 25: ...w for variations in elevation venting and installation configurations and fuel types hard wood soft wood Rotating this dial will adjust the air fuel ratio to the appliance Clockwise adjustments increa...

Page 26: ...art Number OAK 3 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield Firestop Approved Class L or PL Pellet Vent Figure 26 1 CAUTION Never draw outside...

Page 27: ...ssembly 18 120 VAC 300 Watt Wood Pellet Fuel Only SRV7000 647 Y Pkg of 10 SRV7000 647 10 Y Wing Thumb Screw 8 32 X 1 2 Pkg of 24 7000 223 24 Y Wire Clip Pkg of 10 7000 400 10 Y ACCESSORIES Collar Offs...

Page 28: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dea...

Reviews: