Thermostat Setup Options
Setup options for how the thermostat will function are per
-
formed using a menu on the display screen.
TO ACCESS THE SETUP MENU:
Move the System Mode Switch into the OFF position, and
then hold down the COPY button for approximately 5 sec
-
onds until the screen changes. The menu will always start
with item #01, and is advanced to each following item by a
single press of the NEXT button. The options for each item
are changed using the
UP
or
DOWN
buttons.
ITEM #01 (CLK = CLOCK FORMAT):
• 12Hr, default: This displays the clock times using stan-
dard AM and PM values.
• 24Hr: This displays the clock times using the military-
time format (example 22:00 hours, without using AM
or PM).
ITEM #02 (TMP = TEMPERATURE SCALE):
•
F, default: Shows all temperature values in Fahrenheit.
•
C: Shows all temperature values Celsius.
ITEM #03 (PROGRAMMING STYLE):
•
7 Day, default:
This style uses a separate program
routine for each of the 7 days in the week.
•
5/2 Day:
This style uses a weekday program routine
for Monday, Tuesday, Wednesday, Thursday, Friday,
and a separate weekend program routine for Saturday
and Sunday.
• Manual Non-Programmable:
In this setting, there are
no program routines for the thermostat to follow and
the temperature control will be set only by the UP and
DOWN buttons on the front panel.
ITEM #04 (PERD = EVENT OR PERIOD QUANTITY):
• 4P, default: Thermostat uses four Events per day
(called
MORN, DAY, EVE
, and
NITE
).
• 2P: The thermostat uses two Events per day (called
DAY
and
NITE
).
NOTE:
Event or Period Quantity feature is not accessible
during Manual Non-Programmable mode.
ITEM #07 (DLAY = DELAY TIME):
• 5, default: Thermostat waits 5 minutes before turning
the system back on after it was last run. This inter-
nal delay prevents the appliance from turning on too
quickly after shutting down. The 5 minute setting is
fine for most applications.
• 2:
Same operation as above but reduced to 2 minutes
between state changes.
NOTE:
This delay does not
happen when the thermostat is manually turned up
and down.
ITEM #08 (TEMPERATURE DIFFERENTIAL):
• The thermostat works by turning your heating system
on and off whenever the room temperature varies
from the desired set-point temperature.
•
Use the UP/DOWN buttons to change the number
value between 1 and 9. Generally your system should
cycle on about 3 to 6 times per hour. A smaller dif-
ferential number makes the system cycle more fre-
quently, so the room temperature is more precise and
constant. A larger differential number will make the
system remains on for a longer duration each time and
decreases the number of cycles per hour.
• Default is set to 4.
Operating Instructions
SET DAY AND TIME:
Place the
SET switch into the DAY/TIME position. With
the day flashing press UP or DOWN to set the day or the
week. Press NEXT and the clock time will start flashing.
Use UP or DOWN to set the time; verify the AM/PM indica
-
tor is correct. Return the
SET switch to RUN position when
finished.
HEATING:
Basic operation of the thermostat can be obtained with the
SET switch in the RUN position. The temperature can be
adjusted using the UP and DOWN buttons. When the ther
-
mostat is first powered on, it will follow a default tempera
-
ture routine that is preset from the factory.
Event
Time
Temperature
MORN
6:00 AM
70°F (21°C)
DAY
8:00 AM
62°F (17°C)
EVE
6:00 PM
70°F (21°C)
NITE
10:00 PM
62°F (17°C)
LCD DISPLAY BACKLIGHT:
The display screen is lighted to assist viewing at night-
time, or in locations with low light levels. Press any button
on the front panel to activate the approximate 10 second
backlight.
TEMPERATURE OVERRIDE:
While thermostat is in RUN mode, the set temperature can
be temporarily changed by pressing UP or DOWN. The
temporarily changed set temperature will return to the pro-
grammed value stored in memory when start time of the
next upcoming scheduled event is reached (MORN, DAY,
EVE, OR NITE). While the temporary changed set tem
-
perature is in effect, the word OVERRIDE will be shown
on the display screen. To cancel, move TEMPERATURE
switch to OFF and back to HEAT again.
TEMPERATURE HOLD:
Temperature hold is used for maintaining a fixed set
temperature; once a
HOLD
is initiated, the thermostat
will maintain the set temperature indefinitely. To enter a
HOLD state, press the HOLD button one time and the
word HOLD will appear on the display. To cancel, press
the HOLD button once again.
13