7. Baffle Removal and Installation
Figure 4.8
Removing Baffle Protection Channel
8. Fan Replacement
The Fireplace comes equipped with two fans, installed
at the factory with electric access on both sides of the
fireplace.
CAUTION!
Risk of Shock!
Disconnect power by turn
-
ing off circuit breaker before servicing or unplugging
control board from junction box in behind the access
panel..
• Fan Replacement Instructions
• Remove all ash from firebox and place into a metal
container.
• Remove the baffle protection channel by lifting it up
and turning it down and pulling it out of the firebox.
See Figure 4.8.
WARNING! Hot Surfaces!
Glass and other surfaces are hot during operation AND cool
down.
DO NOT
clean fireplace until it is cooled.
•
The baffle board is in two pieces. Pull one piece at a
time forward, tilting it down and out. See Figure 4.9.
• Remove the other piece the same way.
•
If replacing the ceramic blanket, pull it forward/down
and out.
• Reinstall the ceramic blanket up and over the
manifold tubes, making sure it is laying flat and
pushed back.
•
Reinstall the baffle boards and the baffle protection
channel. See Figures 4.10 and 4.11.
Figure 4.10
Reinstall Baffle Boards
Protection Channel
Figure 4.11
Reinstall Baffle Protection Channel
Fans are located behind
these Access Panels
Lower Face removed for picture clarity
Figure 4.12 Fan Locations
Figure 4.9
Baffle Board Locations
31
Quadra-Fire • Pioneer III Owner’s Manual • 4182-900 • Rev D • 08/19