19
Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18
Figure
8.2 IntelliFire™ Touch Wiring Diagram
FLAME
SENSE
IGNITER
TO CORD
ASSMBLY
110-120 VAC
FAN 110-120 VAC
RF MODULE
6V TRANSFORMER
PLUG
I
S
6 PIN
BATTERY PACK
ORANGE
(PILOT)
GREEN
(MAIN)
IFT-RC400
REMOTE
CONTROL
BLK
RED
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
BLK
RED
MODULE
RESET
SWITCH
TO CORD ASSEMBLY 110-120 VAC
2550-013 (NG)
2550-014 (LP)
2326-131
2326-152
2326-130
2326-150
2550-135
2206-299
2326-120
2166-302 (NG)
2166-303 (LP)
2550-301
GFK-210-C
2326-134
2550-753
LIGHT WIRE
ASSEMBLY
2532-017
2201-150
HALOGEN BULBS (X 2)
B. Wiring Requirements - IntelliFire™ Touch
Ignition System Wiring
NOTICE:
Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.2, IntelliFire
TM
Touch (IFT) Wiring
Diagram.
• This appliance is equipped with an IntelliFire control valve
which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the supplied cord
assembly to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
Battery Pack
Battery pack is not factory installed in appliances. See
appliance manual bag for battery pack. Battery pack
should only be installed during power outages.