2700-I WOOD INSERT (ACT)
Page 12
September 1, 2008
R
7007-161H
OpTIONAL qUICK CONNECT COLLAR
OUTSIDE AIR INSTALLATION
The Outside Air Cover Boxes must be installed
on both panel legs FIRST before installing the
panels on the insert. The boxes are included
with the panel and Trim Kit Assembly.
NOTE: The Factory-Built Fireplace must meet (UM) 84-
HUD requirements for outside combustion air supply to
the fireplace fire chamber.
1. Slide the Outside Air Cover Box over the louvers in
the panel leg and wedge it between the panel leg and
flange. Secure with screw provided.
2. Repeat for other side.
Chimney Ring Bolts
Grap handle and pull
venting into firebox
Turn clockwise to lock
Line up slot
with chimney
ring bolt
Secure venting
to collar
I
f you would like to use the Quick Connect Collar for easy
flue installation and removal, follow the directions below.
1. Attach venting to Quick Connect Collar. Secure with 2
screws.
2. Remove baffle and ceramic blanket.
See page 20.
. Partially insert chimney ring bolts (1/4-20) supplied in
component pack.
4. Slide appliance into place.
5. From inside the unit, reach through chimney ring hole,
grab the horizontal bar handle pulling venting to the unit.
Line up the slots in Quick Connect Collar with the bolts.
6. Rotate Quick Connect Collar clockwise and tighten
bolts.
7. Re-install baffle and ceramic blanket making sure they
are fully pushed back into position.
Outside Air Inlet
Outside Air
Cover Box
Back of
Panel
Figure 12.1
Figure 12.2
Figure 12.3
WARNING
Do not draw outside combustion air from:
• Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
• Close proximity to exhaust vents or chimneys.
Fumes or odor may result
Fire Risk.
Asphyxiation Risk.
Asphyxiation Risk.
Outside air inlet must be located to prevent blockage
from:
• Leaves, snow, ice or other debris
Blockage may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensitive
individuals
WARNING
Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed
the length of the vertical height of the exhaust flue.
•
Fire will not burn properly
•
Smoke spillage occurs when door is opened due
to air starvation
WARNING