4300 Wood Stove Series (ACC)

Hearth & Home Technologies welcomes you to our tradi

-

tion of excellence!  In choosing a Quadra-Fire appliance, 

you have our assurance of commitment to quality, durabil

-

ity, and performance.
This commitment begins with our research of the market, 

including ‘Voice of the Customer’ contacts, ensuring we 

make products that will satisfy your needs. Our Research 

and Development facility then employs the world’s most 

advanced technology to achieve the optimum operation of 

our stoves, inserts and fireplaces.  And yet we are old-fash

-

ioned when it comes to craftsmanship.  Each unit is meticu

-

lously fabricated and surfaces are hand-finished for lasting 

beauty and enjoyment.  Our pledge to quality is completed 

as each model undergoes a quality control inspection.   
We wish you and your family many years of enjoyment in 

the warmth and comfort of your hearth appliance.  Thank 

you for choosing Quadra-Fire.

and Welcome to the Quadra-Fire Family

!

Serial No.

Model Name

Test Lab & 

Report No.

Mfg. Date

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION:  BACK OF APPLIANCE

INSTALLATION: FULL VERTICAL OR HORIZONTAL WITH MINIMUM 2 FOOT VERTICAL OFF STOVE TOP

INSTALLATION: ENTIÈREMENT VERTICALE OU HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE

SINGLE WALL PIPE

H

Flat Top Model

18 (457)  15.5 (394)  26 (660)  17 (432)  10 (255)  18.5 (470)  52.5 (1334)  18 (457)*

Step Top Model

12 (305)  8.5 (216)  23 (584)  13 (330)  2 (51)  13 (330) 

50.5 (1283)  18 (457)*

DOUBLE WALL PIPE

 Flat Top Model

13 (330)  10.5 (267)  24.5 (622)  15 (381)  10 (255)  18.5 (470)  52.5 (1334)  10 (254)

Step Top Model

10 (254)  6.5 (165)  23 (584)  13 (330)  2 (51)  13 (330) 

50.5 (1283)  5 (127)

INSTALLATION:  90o ELBOW OFF TOP OF STOVE THROUGH BACKWALL

INSTALLATION:  90o DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIÈRE

DOUBLE WALL PIPE

 Flat Top Model

8.5 (216)  6 (152)  24.5 (622)  15 (381)  10 (254)  18.5 (470)  52.5 (1334)  18 (457)*

 Step Top Model

7.5 (191)  4 (102)  19 (483)  9 (229)  2 (51)  13 (330) 

50.5 (1283)  18 (457)*

I

NSTALLATION:   ALCOVE -

 Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT* listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home 

must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1220mm) with a minimum height of 45.5 inches (1156mm) to top of unit, and the referenced clearances.  Please 

refer to the clearances below for minimum Alcove height requirement to top of unit.

INSTALLATION: ALCÔVE - De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT de Classe "A", ou une cheminée de briques. (Les maisons 

mobiles doivent être équipées d'un arrêt d'étincelle). La profondeur maximum de l'alcôve ne doit pas être de plus de 48 inches (1220mm) avec une hauteur minimum de 45.5 inches (1156mm) du haut de l'appareil, et des espaces 

libres alloués.  Référez vous s'il vous plaît aux dégagements repirs ci-dessus pour la hauteru minimum requise entre le dessus ole l'appareil et l'alcove (de la chimineé).

DOUBLE WALL PIPE

Flat Top Model

 13 (330)     10.5 (267)  24.5 (622)  15 (381) 

N/A 

N/A 

52.5 (1334) 

N/A

 Step Top Model 

10 (254)  6.5 (165)  23 (584)  13 (330) 

N/A 

N/A 

37 (940) 

N/A

*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650oC Factory-built chimney.

*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650oC cheminée bâtit en usine.

*

 NFPA 211 MINIMUM CLEARANCES - NOT TESTED

SPÉCIFICATIONS DE LA VENTILATION:

MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de minimum 

d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine UL103HT* de 

Classe "A", adéquate pour usage avec les combustions solides, ou une cheminée de briques, 

avec espaces libres référés. 

MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé 

pour mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou une cheminée 

de briques, avec espaces libres alloués. 

MAISON MOBILE:  Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk Metalbestos 

DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les espaces libres pour mur 

double comme mentionné ci-bas. 

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters) 

NOTE:  All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar. 

LISTED  ROOM  HEATER,  SOLID  FUEL  TYPE.   

ALSO FOR USE IN MOBILE HOMES. (UM) 84 HUD   

1445 N. Highway, Colville, WA 99114 

www.quadrafire.com 

I

n

stall  and  use  only  in  accordance  with 

manufacturer's  installation  and  operating 

instructions.    Contact  local  building  or  fire 

officials  about  restrictions  and  installation 

inspections  in  your  area.  Do  not  obstruct  the 

space beneath heater.

WARNING - For Mobile Homes:  Do not install 

in a sleeping room.  An outside combustion air 

inlet must be provided and unrestricted while unit 

is in use.  The structural integrity of the mobile 

home floor, ceiling and walls must be maintained.  

The stove needs to be properly grounded to the 

frame of the mobile home.  Components required 

for mobile home installation:  Outside Air Kit, Part 

Number OAK-ACC.

Refer  to  manufacturer's  instructions  and 

local codes for precautions required for passing 

chimney  through  a  combustible  wall  or  ceiling 

and maximum offsets.

Inspect  and  clean  chimney  frequently  -  Under 

Certain Conditions of Use, Creosote Buildup May 

Occur Rapidly.

Do not connect this unit to a chimney serving another 

appliance.

Optional  Components:    Optional  Blower,  Part 

BK-ACC.

Electrical Rating:  115 VAC, 1.2 Amps, 60 Hz.

Route power cord away from unit.  Do not route 

cord under or in front of appliance.

DANGER:  Risk  of  electrical  shock.

Disconnect power supply before servicing.

Replace glass only with 5mm ceramic available 

from your dealer.

Do not use grate or elevate fire.  Build wood fire 

directly on hearth.

Do  not  overfire  -  if  heater  or  chimney 

connector glows, you are overfiring.

Operate  only  with  the  fuel  loading  door 

closed.  Open only to add fuel to the fire.

CAUTION

:

U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to 

comply with July 1990 particulate emission standards. 

2008  2009  2010  Jan.  Feb.  Mar.  Apr.  May  June July  Aug. Sept. Oct.  Nov.  Dec.

PREVENT HOUSE FIRES 

FLOOR PROTECTION

:

Floor  protector  must  be  a  3/8  inch  min.  thickness,  

non-combustible  material  or  equivalent,  extending 

beneath heater and to front/sides/rear as indicated on 

the diagram below. Exception: Non-combustible floor 

protections  must  extend  beneath  the  flue  pipe  when 

installed  with  horizontal  venting  and  extend  2  inches 

(51mm) beyond each side.

O-T L 

Tested and 

Listed by 

Portland

Oregon USA

OMNI-Test Laboratories, Inc. 

C

Report / Rapport

#061-S-67-7

TESTED TO:/ TESTÉ À:

   UL 1482,  ULC S627-00 

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS.  KEEP FURNISHINGS AND OTHER 

COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS. 

VENT SPECIFICATIONS:

SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or blued steel connector 

pipe,  with  a  listed  factory-built  UL103HT*  Class  "A"  chimney,  suitable  for  use  with  solid  fuels,  or  a 

masonry chimney, and the referenced clearances. 

DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air insulated connector pipe 

with  listed  factory-built  UL103HT*  Class  "A"  chimney,  or    a  masonry  chimney  and  the  referenced 

clearances

MOBILE HOME:  Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double 

wall connector pipe. Must be equipped with a spark arrestor.  Apply double wall clearances below when 

installing unit. 

SERIAL NO. 

/

NUMÉRO D

E

SÉRIE

4300 ACC Series 

R

7037-136

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES 

BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. 

ATTENTION: 

APPAREIL  DE  CHAUFFAGE  DE  PIÈCE,  DE  TYPE  DE 

COMBUSTIBLE  SOLIDE,  POUR  USAGE  DANS  LES 

MAISONS  MOBILES.  (UM)  84  HUD. 

"Pour  Usage 

Avec Bois Solide Seulement" 

I

nstallez  et  utilisez  en  accord  avec  les  instructions 

d'installation  et  d'opération  du  fabricant.  Contactez  le 

bureau de la construction ou le bureau des incendies au 

sujet des restrictions et des inspections d'installation dans 

votre voisinage. Ne pas obstruez l'espace en dessous de 

l'appareil.

AVIS - Pour Les Maisons Mobiles:  Ne pas installer dans 

une chambre à coucher. Un tuyau extérieur de combustion 

d'air doit être installé et ne doit pas être obstrué lorsque 

l'appareil est en usage. La structure intégrale du plancher, 

du  plafond  et  des  murs  de  la  maison  mobile  doit  être 

maintenue intacte. L'appareil de chauffage doit être fixé à 

la charpente de la maison mobile. Les composants requis 

pour  l'installation  des  maisons  mobiles: Assemblage  d'air 

extérieur, Numéro de Pièce OAK-ACC..

Référez vous aux instructions du fabricant et des codes 

locaux  pour  les  précautions  requises  pour  passer  une 

cheminée à travers un mur ou un plafond combustibles, et les 

compensations maximums.

Inspectez  et  nettoyez  la  cheminée  fréquemment.  Sous 

certaines conditions, il se peut que la créosote s'accumule 

rapidement.

Ne pas connecter cet appareil à une cheminée servant un 

autre appareil.

Composants  Optionnels:  Ventilateur  Optionnel,  Pièce 

BK-ACC.

Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.

Éloignez le fil électrique de l'appareil. Ne pas faire passer 

le fil électrique au dessus ou en dessous de l'appareil.

DANGER:  Il  y  a  risque  de  décharge  électrique.

Déconnectez le fil électrique de la prise de contact avant le 

service.

Remplacez la vitre seulement avec une vitre céramique de 

5 mm disponible chez votre fournisseur.

N'élevez pas le feu. Bâtissez le feu de bois directement sur 

l'âtre.

Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau 

de cheminée rougissent, vous surchauffez.

Opérez  l'appareil  seulement  lorsque  la  porte  de 

chargement est fermée. Ouvrez la porte seulement lorsque 

vous devez ajouter des combustibles dans le feu.

PRÉVENTION DES FEUX DE MAISON 

PROTECTION DU PLANCHER:

Le protecteur de plancher doit être d'un minimum de 3/8 

inch d'épaisseur, de matériel incombustible ou équivalent, 

s'étendant  du  dessous  de  l'appareil  de  chauffage  à 

l'avant,  aux  cotés  et  à  l'arrière  comme  indiqué  sur  le 

diagramme  suivant.  Exception:  Les  protections 

incombustibles du plancher doivent s'étendre en dessous 

du  conduit  de  cheminée  lorsqu'installées  avec  une 

ventilation à l'horizontale et s'étendre de 2 inches (51mm) 

de chaque côté.

ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:En Pouces & (millimètres) 

NOTE:  Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de l'entrée du conduit. 

BACKWALL/SIDEWALL 

MUR ARRIÈRE/MUR DE CÔTÉ  

CORNER INSTALLATION

/

INSTALLATION DU COIN  

ALCOVE TOP VIEW / 

VUE DU HAUT DE L'ALCÔVE

ALCOVE SIDE VIEW /  

VUE DE CÔTÉ DE L'ALCÔVE 

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Made in U.S.A./Fait Aux États-Unis

Manufactured by: 

Fabriqué par: 

G

B

C

D

B

C

D

90

o

 OFF TOP 

UP & OUT CEILING CLEARANCE

ESPACE LIBRE DU DESSUS DE 

L'APPAREIL AU PLAFOND AVEC 90

DE COURBURE 

STOVE TO CEILING CLEARANCE
ESPACE LIBRE DU POÊLE AU 

PLAFOND

G

G

H*

E

F

E

F

G

H

G

B

16" from glass 

8"

USA 

Fuel loading door 

4-1/2"

3-1/2"

31-5/8" minimum 

40-7/16"

minimum

CANADA 

203mm (8") 

203mm

(8")

203mm

(8")

457mm (18") 

1281mm

(50-7/16")

minimum

1080mm (42-1/2") 

minimum

CONDUIT DU MUR SIMPLE 

Modèle au dessus en appartement 

Modèle au dessus en escalier 

CONDUIT DU MUR DOUBLE 

Modèle au dessus en appartement 

Modèle au dessus en escalier 

CONDUIT DU MUR DOUBLE 

Modèle au dessus en appartement 

Modèle au dessus en escalier 

CONDUIT DU MUR DOUBLE 

Modèle au dessus en escalier

Modèle au dessus en appartement 

007003

SAMPLE

Summary of Contents for Quadra-Fire 43M-ACC-MBK

Page 1: ...ood fuel only Other fuels may overfire and generate poisonous gases i e carbon monoxide Installation and service of this appliance should be performed by qualified personnel Hearth Home Technologies r...

Page 2: ...our dealer Do not use grate or elevate fire Build wood fire directly on hearth Do not overfire if heater or chimney connector glows you are overfiring Operate only with the fuel loading door closed Op...

Page 3: ...ction 6 Mobile Home 20 Section 7 Appliance Set Up A Pedestal Ash Removal System ARS Installation 21 22 B Leg Kit Ash Removal System ARS Installation 23 C Door Handle Assembly 24 D Blower Speed Adjustm...

Page 4: ...ide Air Kit part OAK ACC must be installed in a mobile home installation B Mobile Home Approved EPA Certified 1 1 grams per hour EPA Certificate Number and Date Number 656 Issued 02 05 2007 Efficiency...

Page 5: ...sisting of at least two escape routes 4 A plan to deal with a chimney fire as follows In the event of a chimney fire a Evacuate the house immediately b Notify fire department WARNING Do NOT connect th...

Page 6: ...include Exhaust fans kitchen bath etc Range hoods Combustion air requirements for furnaces water heaters and other combustion appliances Clothes dryers Location of return air vents to furnace or air c...

Page 7: ...ce after one hour of operation at each burn setting NOTE These are guidelines only and may vary somewhat for individual installations F Tools And Supplies Needed Before beginning the installation be s...

Page 8: ...ermination Cap Outside Air Rear Vent Spark Arrestor Cap Floor Protector Chimney Connector Ceiling Support Listed Chimney Listed Termination Cap Storm Collar Flashing Figure 8 3 Interior Prefabricated...

Page 9: ...2 in 292mm 16 in 406mm 20 3 4 in 527mm C L 4 1 2 in 108mm Outside Air Connection A Appliance Dimensions Figure 9 1 Front View Figure 9 2 Side View NOTE Flue Collar size is 6 inch 152mm diameter ID Mi...

Page 10: ...Top Leg Model 2 7 8 in 606mm 7 16 in 849mm 15 1 16 in 8 mm 19 1 16 in 484mm 10 15 16 in 278mm 14 15 16 in 79mm 3 11 16 in 94mm 2 1 8 in 587mm 10 8 in 264mm Back of Stove to Glass 25 8 in 645mm 6 11 16...

Page 11: ...75 95 22 559 11 75 298 2 51 12 305 49 5 1283 5 127 INSTALLATION 90 Elbow Off Top of Stove Through Backwall DOUBLE WALL PIPE Flat Top Model 8 5 216 6 152 24 5 622 15 381 10 254 17 5 445 53 5 1359 N A S...

Page 12: ...pening in the face of the appliance See exception 16 from glass 8 in Fuel loading door 4 7 8 in 3 1 8 in 31 5 8 in minimum 41 3 8 in minimum 1 5 8 i n 2 7 8 i n 7 in 4 0 1 5 1 6 i n 1 1 6 i n 135 o p...

Page 13: ...to individual design preference Hearth Home Technologies reserves the right to alter its products 16 in from glass 8 in Fuel loading door 4 3 4 in 3 1 4 in 1 5 8 in minimum 41 8 in minimum 20 mm 8 in...

Page 14: ...mes that have tightly sealed doors and windows an outside air source is needed An optional Outside Air Kit is available Flex Line Wire Tie Wire Tie Flex Adapter Termination Cap Remove circular knock o...

Page 15: ...appliance 4 Place the bracket containing the snap disc and magnet under the bottom left rear corner as shown in Figure 15 1 See page 30 for detailed operating instructions for the blower and snap disc...

Page 16: ...ld steel black or 26 gauge blued steel or an approved air insulated double wall venting pipe Thimble A manufactured or site constructed device installed in combustible walls through which the chimney...

Page 17: ...framing lumber to fit into wall opening Inside opening of frame should be no less than 14 inch x 14 inch 356mm x 356mm Figure 17 1 4 Attach the wall spacer to the chimney side of the frame 5 Nail the...

Page 18: ...nectors must conform to each other to ensure a proper fit and seal Flue Gas Direction Crimped End Toward Stove Secure pipe sections with a minimum of screws Figure 18 2 Chimney Connector Stove Pipe WA...

Page 19: ...of the roof within 10 feet 305cm Must be located away from trees or other struc tures These are safety requirements and are not meant to assure proper flue draft Figure 19 1 E 2 10 3 Rule Figure 19 2...

Page 20: ...onnector manufacturer s instructions when installing the flue system for use in a mobile home 7 Maintain clearance to combustibles 8 Floor protection requirements must be followed precisely 9 Use sili...

Page 21: ...ed Phillips head screwdriver 7 16 socket wrench 3 32 and 5 36 Allen wrench Begin installing the ARS System 1 Remove 2 front bricks as shown in Figure 21 1 2 Lay body of stove on its back on a protecti...

Page 22: ...Carefully stand stove up and place in desired location 5 Slip wooden decorative strips onto pedestal edges Finishing the ARS Installation 1 Re install the ARS channel that was removed in Step 3 on pag...

Page 23: ...he bottom of the stove with 1 4 20 Phillips head screws These screws are located in the component pack Leave the bottom 2 screws loose so you can slide the ash pan assembly bottom slots over the screw...

Page 24: ...to slow the blower and counterclockwise to increase the speed The blower speed control for this unit is adjusted at the factory and normally does not require further adjustment D Adjusting The Blower...

Page 25: ...d establishing the flue draft not evaporating the moisture out of wet unseasoned wood resulting in wasted heat Do not over fire Over firing may ignite creosote or will damage the stove and chimney To...

Page 26: ...his function is performed by sliding the con trol all the way back until it stops at the HI indicator on the label and then pulling forward to the front of the stove until it stops This activates the...

Page 27: ...This air is regulated by the Burn RateAir Control There are four settings High Medium High Medium Low and Low When the control is raised all the way up it is on the High setting and when pushed all th...

Page 28: ...102mm in diameter Be careful not to smother the fire Stack the pieces of wood carefully near enough to keep each other hot but far enough away from each other to allow adequate air flow between them 7...

Page 29: ...e 29 2 Ceramic Blanket and Baffle Board MUST be in contact with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Figure 29 1 H Correct Baffle...

Page 30: ...e is a manual over ride switch to deactivate the snap disc if necessary See page 15 I Blower Operating Instructions Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids...

Page 31: ...It is also recommended that before each heating season the entire system be professionally inspected cleaned and repaired if necessary a The stove and ashes must be completely cooled down before using...

Page 32: ...cially available oven cleaner After using an oven cleaner it is advisable to remove any residue with a glass cleaner or soap and water Oven cleaner left on during the next firing can permanently stain...

Page 33: ...ach retainer just a few turns until each is secured Check again for centering of glass in door frame Continue to tighten each retainer alternately a few turns at a time until the glass is secure DO NO...

Page 34: ...ks Slide top of brick under clips on side of firebox and push the bottom of the brick until it is flush with the side of the appliance C Firebrick Replacement Use Part 832 0550 when ordering individua...

Page 35: ...lace on top of baffle board open up and flatten and smooth out the blanket Re check the baffle board for correct positioning Figure 35 2 Figure 35 1 Baffle Figure 35 2 Ceramic Blanket E Snap Disc Repl...

Page 36: ...he tube channel assembly into side of firebox and insert each tube into the corresponding hole in the tube channel rack starting with the back hole first 3 Make sure tube channel assembly is flush aga...

Page 37: ...e appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to wood fuel sec tion Bed of coals not established before adding wood Start with paper kindling to establis...

Page 38: ...oor Assembly only Gold 430 2682 Nickel 430 5340 43 Glass Replacement 7000 012 44 Cam Latch 430 1141 45 Nut Locking 24 226 0100 24 46 Key Cam Latch 430 1151 47 Screws Glass Frame 10 1 220 0490 10 832 0...

Page 39: ...t Up Air Control 23 Air Supply Back 5 Magnet for Air Control 24 Flue Collar 6 Air Control Rod Guide Start Up 25 Panel Assembly Side Left 7 Control Arm Assembly Rear Air 26 Rear Air Channel Assembly 9...

Page 40: ...sembly Rear Air 31 Door Cast not sold separately 9 Timer Mechanical 32 Spring Handle 1 2 inch 10 Timer Arm Assembly 33 Baffle Fiberboard 2 pc 12 Gasket Front Rear Air Doors 34 Brick Retainer 13 Burn R...

Page 41: ...llennium SRV7037 003 50 Brick Set Step Top Model SRV7037 012 Brick Uncut Set of 6 832 3040 13 Burn Rate Air Control Assembly 7037 004 44 Cam Latch Door Handle 430 1141 Channel Ash Removal System Step...

Page 42: ...ue Collar Millennium Model SRV7000 302 Gasket Ash Removal Step Top Model 7033 185 Gasket Tape Glass 5 ft 832 0460 12 Gasket Front Rear Air Timer Doors 7033 282 43 Glass Assembly 15 1 2 W x 13 3 8 H 70...

Page 43: ...4 inch Gold 832 0630 14 Spring Handle Burn Rate Control 1 4 inch Nickel 250 8340 32 Spring Handle Door 1 2 inch Gold 832 0620 32 Spring Handle Door 1 2 inch Nickel 250 8330 49 Timer Air Control Assem...

Page 44: ...Page 44 7037 135E September 1 2008 R 4300 Wood Stove Series ACC Date of Service Performed By Description of Service C Service And Maintenance Log...

Page 45: ...September 1 2008 7037 135E Page 45 4300 Wood Stove Series ACC R D Homeowner s Notes...

Page 46: ...onditions Exclusions and limitations 9 01 08 CONDITIONS EXCLUSIONS LIMITATION OF LIABILITY This warranty applies to the original owner and is transferable up to two years from date of purchase to the...

Page 47: ...chlorine fluorine or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation or there is any damage to the appliance or other components due to water or wea...

Page 48: ...95 6053165 6145502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302B2 6715724B2 6729551 6736133 6748940 6748942 6769426 6774802 6796302 6840261 6848441 6...

Reviews: