B.  Wood Selection & Storage

Burn only dry seasoned wood.  Store wood under cover, out 

of the rain and snow.  Dry and well-seasoned wood will not 

only minimize the chance of creosote formation, but will give 

you the most efficient fire.  Even dry wood contains at least 

15% moisture by weight, and should be burned hot enough 

to keep the chimney hot for as long as it takes to dry the 

C.  Burning Process

In recent years there has been an increasing concern about 

air quality.  Much of the blame for poor air quality has been 

placed on the burning of wood for home heating. In order to 

improve  the  situation,  we  at  Quadra-Fire  have  developed 

cleaner-burning woodstoves that surpass the requirements 

for emissions established by our governing agencies.  These 

woodstoves,  like  any  other  appliances,  must  be  properly 

operated in order to insure that they perform the way they are 

designed to perform.  Improper operation can turn most any 

wood stove into a smoldering environmental hazard.

1.  Kindling or First Stage

It helps to know a little about the actual process of burning in 

order to understand what goes on inside a stove.  The first 

stage of burning is called the kindling stage.  In this stage, the 

wood is heated to a temperature high enough to evaporate the 

moisture which is present in all wood.  The wood will reach 

the boiling point of water (212°F) and will not get any hotter 

until the water is evaporated.  This process takes heat from 

the coals and tends to cool the appliance.
Fire requires three things to burn - fuel, air and heat.  So, if 

heat is robbed from the appliance during the drying stage, 

the new load of wood has reduced the chances for a good 

clean burn.  For this reason, it is always best to burn dry, 

seasoned  firewood.    When  the  wood  isn’t  dry,  you  must 

open the air controls and burn at a high burn setting for a 

longer time to start it burning.  The heat generated from the 

fire should be warming your home and establishing the flue 

draft, not evaporating the moisture out of wet, unseasoned 

wood, resulting in wasted heat.

Do not over-fire.
Over-firing  may  ignite  creosote  or  will  damage 

the stove and chimney.
To prevent over-firing your stove, DO NOT:
•  Use flammable liquids

•  Overload with wood

•  Burn trash or large amounts of scrap lumber

•  Permit too much air to the fire

WARNING

Fire Risk

Symptoms of over-firing may include one or more of the 

following:
  •  Chimney connector or appliance glowing
  •  Roaring, rumbling noises
  •  Loud cracking or banging sounds
  •  Metal warping
  •  Chimney fire

1. Symptoms of Over-Firing

2. What To Do if Your Stove is Over-Firing

  •  Immediately close the door and air controls to reduce 

air supply to the fire.

  •  If you suspect a chimney fire, call the fire department 

and evacuate your house.

  •  Contact your local chimney professional and have your 

stove and stove pipe inspected for any damage.

  •  Do not use your stove until the chimney professional 

informs you it is safe to do so.

Hearth & Home Technologies WILL NOT warranty stoves 

that exhibit evidence of over-firing.  Evidence of over-firing 

includes, but is not limited to:
  •  Warped air tube
  •  Deteriorated refractory brick retainers
  •  Deteriorated baffle and other interior components

A.  Over-Firing Your Appliance

B.  Wood Selection & Storage (Cont’d)

wood out - about one hour.  It is a waste of energy to burn 

unseasoned wood of any kind.
Dead wood lying on the forest floor should be considered 

wet, and requires full seasoning time.  Standing dead wood 

can be considered to be about 2/ seasoned.  To tell if wood 

is dry enough to burn, check the ends of the logs.  If there 

are cracks radiating in all directions from the center, it is dry.  

If your wood sizzles in the fire, even though the surface is 

dry, it may not be fully cured.  
Splitting  wood  before  it  is  stored  reduces  drying  time.  

Wood should be stacked so that both ends of each piece 

are exposed to air, since more drying occurs through the 

cut ends than the sides.  This is true even with wood that 

has been split.  Store wood under cover, such as in a shed, 

or covered with a tarp, plastic, tar paper, sheets of scrap 

plywood, etc., as uncovered wood can absorb water from 

rain or snow, delaying the seasoning process.

Summary of Contents for Quadra-Fire 43M-ACC-MBK

Page 1: ...ood fuel only Other fuels may overfire and generate poisonous gases i e carbon monoxide Installation and service of this appliance should be performed by qualified personnel Hearth Home Technologies r...

Page 2: ...our dealer Do not use grate or elevate fire Build wood fire directly on hearth Do not overfire if heater or chimney connector glows you are overfiring Operate only with the fuel loading door closed Op...

Page 3: ...ction 6 Mobile Home 20 Section 7 Appliance Set Up A Pedestal Ash Removal System ARS Installation 21 22 B Leg Kit Ash Removal System ARS Installation 23 C Door Handle Assembly 24 D Blower Speed Adjustm...

Page 4: ...ide Air Kit part OAK ACC must be installed in a mobile home installation B Mobile Home Approved EPA Certified 1 1 grams per hour EPA Certificate Number and Date Number 656 Issued 02 05 2007 Efficiency...

Page 5: ...sisting of at least two escape routes 4 A plan to deal with a chimney fire as follows In the event of a chimney fire a Evacuate the house immediately b Notify fire department WARNING Do NOT connect th...

Page 6: ...include Exhaust fans kitchen bath etc Range hoods Combustion air requirements for furnaces water heaters and other combustion appliances Clothes dryers Location of return air vents to furnace or air c...

Page 7: ...ce after one hour of operation at each burn setting NOTE These are guidelines only and may vary somewhat for individual installations F Tools And Supplies Needed Before beginning the installation be s...

Page 8: ...ermination Cap Outside Air Rear Vent Spark Arrestor Cap Floor Protector Chimney Connector Ceiling Support Listed Chimney Listed Termination Cap Storm Collar Flashing Figure 8 3 Interior Prefabricated...

Page 9: ...2 in 292mm 16 in 406mm 20 3 4 in 527mm C L 4 1 2 in 108mm Outside Air Connection A Appliance Dimensions Figure 9 1 Front View Figure 9 2 Side View NOTE Flue Collar size is 6 inch 152mm diameter ID Mi...

Page 10: ...Top Leg Model 2 7 8 in 606mm 7 16 in 849mm 15 1 16 in 8 mm 19 1 16 in 484mm 10 15 16 in 278mm 14 15 16 in 79mm 3 11 16 in 94mm 2 1 8 in 587mm 10 8 in 264mm Back of Stove to Glass 25 8 in 645mm 6 11 16...

Page 11: ...75 95 22 559 11 75 298 2 51 12 305 49 5 1283 5 127 INSTALLATION 90 Elbow Off Top of Stove Through Backwall DOUBLE WALL PIPE Flat Top Model 8 5 216 6 152 24 5 622 15 381 10 254 17 5 445 53 5 1359 N A S...

Page 12: ...pening in the face of the appliance See exception 16 from glass 8 in Fuel loading door 4 7 8 in 3 1 8 in 31 5 8 in minimum 41 3 8 in minimum 1 5 8 i n 2 7 8 i n 7 in 4 0 1 5 1 6 i n 1 1 6 i n 135 o p...

Page 13: ...to individual design preference Hearth Home Technologies reserves the right to alter its products 16 in from glass 8 in Fuel loading door 4 3 4 in 3 1 4 in 1 5 8 in minimum 41 8 in minimum 20 mm 8 in...

Page 14: ...mes that have tightly sealed doors and windows an outside air source is needed An optional Outside Air Kit is available Flex Line Wire Tie Wire Tie Flex Adapter Termination Cap Remove circular knock o...

Page 15: ...appliance 4 Place the bracket containing the snap disc and magnet under the bottom left rear corner as shown in Figure 15 1 See page 30 for detailed operating instructions for the blower and snap disc...

Page 16: ...ld steel black or 26 gauge blued steel or an approved air insulated double wall venting pipe Thimble A manufactured or site constructed device installed in combustible walls through which the chimney...

Page 17: ...framing lumber to fit into wall opening Inside opening of frame should be no less than 14 inch x 14 inch 356mm x 356mm Figure 17 1 4 Attach the wall spacer to the chimney side of the frame 5 Nail the...

Page 18: ...nectors must conform to each other to ensure a proper fit and seal Flue Gas Direction Crimped End Toward Stove Secure pipe sections with a minimum of screws Figure 18 2 Chimney Connector Stove Pipe WA...

Page 19: ...of the roof within 10 feet 305cm Must be located away from trees or other struc tures These are safety requirements and are not meant to assure proper flue draft Figure 19 1 E 2 10 3 Rule Figure 19 2...

Page 20: ...onnector manufacturer s instructions when installing the flue system for use in a mobile home 7 Maintain clearance to combustibles 8 Floor protection requirements must be followed precisely 9 Use sili...

Page 21: ...ed Phillips head screwdriver 7 16 socket wrench 3 32 and 5 36 Allen wrench Begin installing the ARS System 1 Remove 2 front bricks as shown in Figure 21 1 2 Lay body of stove on its back on a protecti...

Page 22: ...Carefully stand stove up and place in desired location 5 Slip wooden decorative strips onto pedestal edges Finishing the ARS Installation 1 Re install the ARS channel that was removed in Step 3 on pag...

Page 23: ...he bottom of the stove with 1 4 20 Phillips head screws These screws are located in the component pack Leave the bottom 2 screws loose so you can slide the ash pan assembly bottom slots over the screw...

Page 24: ...to slow the blower and counterclockwise to increase the speed The blower speed control for this unit is adjusted at the factory and normally does not require further adjustment D Adjusting The Blower...

Page 25: ...d establishing the flue draft not evaporating the moisture out of wet unseasoned wood resulting in wasted heat Do not over fire Over firing may ignite creosote or will damage the stove and chimney To...

Page 26: ...his function is performed by sliding the con trol all the way back until it stops at the HI indicator on the label and then pulling forward to the front of the stove until it stops This activates the...

Page 27: ...This air is regulated by the Burn RateAir Control There are four settings High Medium High Medium Low and Low When the control is raised all the way up it is on the High setting and when pushed all th...

Page 28: ...102mm in diameter Be careful not to smother the fire Stack the pieces of wood carefully near enough to keep each other hot but far enough away from each other to allow adequate air flow between them 7...

Page 29: ...e 29 2 Ceramic Blanket and Baffle Board MUST be in contact with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Figure 29 1 H Correct Baffle...

Page 30: ...e is a manual over ride switch to deactivate the snap disc if necessary See page 15 I Blower Operating Instructions Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids...

Page 31: ...It is also recommended that before each heating season the entire system be professionally inspected cleaned and repaired if necessary a The stove and ashes must be completely cooled down before using...

Page 32: ...cially available oven cleaner After using an oven cleaner it is advisable to remove any residue with a glass cleaner or soap and water Oven cleaner left on during the next firing can permanently stain...

Page 33: ...ach retainer just a few turns until each is secured Check again for centering of glass in door frame Continue to tighten each retainer alternately a few turns at a time until the glass is secure DO NO...

Page 34: ...ks Slide top of brick under clips on side of firebox and push the bottom of the brick until it is flush with the side of the appliance C Firebrick Replacement Use Part 832 0550 when ordering individua...

Page 35: ...lace on top of baffle board open up and flatten and smooth out the blanket Re check the baffle board for correct positioning Figure 35 2 Figure 35 1 Baffle Figure 35 2 Ceramic Blanket E Snap Disc Repl...

Page 36: ...he tube channel assembly into side of firebox and insert each tube into the corresponding hole in the tube channel rack starting with the back hole first 3 Make sure tube channel assembly is flush aga...

Page 37: ...e appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to wood fuel sec tion Bed of coals not established before adding wood Start with paper kindling to establis...

Page 38: ...oor Assembly only Gold 430 2682 Nickel 430 5340 43 Glass Replacement 7000 012 44 Cam Latch 430 1141 45 Nut Locking 24 226 0100 24 46 Key Cam Latch 430 1151 47 Screws Glass Frame 10 1 220 0490 10 832 0...

Page 39: ...t Up Air Control 23 Air Supply Back 5 Magnet for Air Control 24 Flue Collar 6 Air Control Rod Guide Start Up 25 Panel Assembly Side Left 7 Control Arm Assembly Rear Air 26 Rear Air Channel Assembly 9...

Page 40: ...sembly Rear Air 31 Door Cast not sold separately 9 Timer Mechanical 32 Spring Handle 1 2 inch 10 Timer Arm Assembly 33 Baffle Fiberboard 2 pc 12 Gasket Front Rear Air Doors 34 Brick Retainer 13 Burn R...

Page 41: ...llennium SRV7037 003 50 Brick Set Step Top Model SRV7037 012 Brick Uncut Set of 6 832 3040 13 Burn Rate Air Control Assembly 7037 004 44 Cam Latch Door Handle 430 1141 Channel Ash Removal System Step...

Page 42: ...ue Collar Millennium Model SRV7000 302 Gasket Ash Removal Step Top Model 7033 185 Gasket Tape Glass 5 ft 832 0460 12 Gasket Front Rear Air Timer Doors 7033 282 43 Glass Assembly 15 1 2 W x 13 3 8 H 70...

Page 43: ...4 inch Gold 832 0630 14 Spring Handle Burn Rate Control 1 4 inch Nickel 250 8340 32 Spring Handle Door 1 2 inch Gold 832 0620 32 Spring Handle Door 1 2 inch Nickel 250 8330 49 Timer Air Control Assem...

Page 44: ...Page 44 7037 135E September 1 2008 R 4300 Wood Stove Series ACC Date of Service Performed By Description of Service C Service And Maintenance Log...

Page 45: ...September 1 2008 7037 135E Page 45 4300 Wood Stove Series ACC R D Homeowner s Notes...

Page 46: ...onditions Exclusions and limitations 9 01 08 CONDITIONS EXCLUSIONS LIMITATION OF LIABILITY This warranty applies to the original owner and is transferable up to two years from date of purchase to the...

Page 47: ...chlorine fluorine or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation or there is any damage to the appliance or other components due to water or wea...

Page 48: ...95 6053165 6145502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302B2 6715724B2 6729551 6736133 6748940 6748942 6769426 6774802 6796302 6840261 6848441 6...

Reviews: