R
Page 6
September 1, 2008
Cumberland Gap Wood Stove
7006-188E
B
A
C1
Non-fuel
door side
D2
Fuel Door
side
C2
D1
CLEARANCES TO COMBUSTIBLES (UL and ULC)
G
(Ceiling)
H
E1
E2
F1
F2
Fuel door
side
Non-fuel
door side
G
(Ceiling)
Max Mantel Depth
10" (254mm)
G
(Mantel)
IF SIDE FUEL LOADING DOOR IS NOT USED:
• Must remain in the locked position at all times
• Use clearances for non-fuel side door for both sides
TOP VENT VERTICAL
A B
C1 C2
D1 D2
E1
E2 F1 F2 G H
Single Wall-USA
13(330) 11.5(292) 27(686) 27(686) 18(457) 18(457) 16.5(419) 16.5(419) 20(508) 20(508) 56.5(1435) N/A
Single Wall-Canada
13(330) 11.5(292) 27(686) 27(686) 18(457) 18(457) 16.5(419) 18(457) 20(508) 21.5
(546)
56.5(1435) N/A
Double Wall-USA
12(305) 10.5(267) 25(635) 26(660) 15(381) 16(406) 11(279) 16(406) 14(356) 19(483) 56.5(1435) N/A
Double Wall-Canada
12(305) 10.5(267) 25(635) 28(711) 15(381) 18(457) 11(279) 18(457) 14(356) 21(533) 56.5(1435) N/A
HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP.
(Note: Horizontal must be with 2ft (609mm) vertical
and NOT directy off stove).
Single Wall-USA
13.5(343)
12(305)
27(686)
27(686)
17(432)
17(432)
N/A
N/A N/A N/A
42.5(1080) 10.5(267)
Single Wall-Canada
13.5(343) 12(305) 27(686) 28(711) 17(432) 18(457) N/A
N/A
N/A
N/A
42.5(1080) 10.5(267)
Double Wall-USA
11(279)
9.5(241)
27(686)
27(686)
17(432)
17(432)
N/A
N/A N/A N/A
39(991)
8(203)
Double Wall-Canada
11(279) 9.5(241) 27(686) 28(711) 17(432) 18(457) N/A
N/A
N/A
N/A
39(991)
8(203)
ALCOVE -
Six inch (6") (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT listed factory-built Class "A"
chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.)
Double Wall-USA
12(305)
10.5(267)
25(635)
26(660)
15(381)
16(406)
N/A
N/A N/A N/A
44(1118)
N/A
Double Wall-Canada
12(305)
10.5(267)
25(635) 28(711) 15(381)
18(457)
N/A N/A
N/A N/A 44(1118) N/A
REAR VENT INSTALLATIONS IN A MASONRY FIREPLACE OR THROUGH THE WALL . HORIZONTAL FLUE HEAT SHIELD, PART HTSHLD-7006,
REQUIRED ON REAR VENT INSTALLATIONS
:
Six inch (6") (152mm) diameter listed double wall air insulated connector pipe with UL103 HT listed
factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Additional specifications include a
MAXIMUM 10" (254mm) MANTEL WIDTH
and the following clearances.
Double Wall-USA
N/A 12(305)
27(686) 27(686)
17.5(445)
17.5(445)
N/A N/A N/A N/A
39(991)
ceiling
N/A
Double Wall-Canada
N/A 12(305)
27(686)
27.5(699)
17.5(445)
18(457)
N/A N/A N/A N/A
39(991)
ceiling
N/A
USA or Canada - Single or Double Wall Pipe
: 31(787)
mantel
N/A
USA or Canada - Single or Double Wall Pipe
: 24(610)
mantel
*
N/A
*
with metal shield spaced 1" (25mm) away from bottom mantel surface
HEARTH MOUNT - SIDE DOOR MUST BE LOCKED CLOSED
Single Wall-USA
18(457)
10(254)
22(559)
31(787)
N/A
N/A
N/A
N/A N/A
N/A N/A N/A
Single Wall-Canada
18(457)
10(254)
22(559) 31(787) N/A N/A N/A N/A N/A N/A
N/A
N/A
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
Max Depth
Min Width
Min Height
Front Door
48(1219)
55(1397)
72(1829)
Side Door-USA
48(1219)
57(1448)
72(1829)
Side Door-Canada
48(1219)
61(1549)
72(1829)
NOTE: Optional Fire Screen, Part SCR-7006, can only be used in FULL Vertical
installations