Page 14
7001-142C
November 2, 2005
Santa Fe Pellet Stove
R
R
R
We recommend a minimum of 60 in.
(1524mm) vertical, however above the
eave is preferred.
Both installations are approved for mobile
home installations. Must use 3 or 4 inch (76
to 102mm) “L” or “PL” listed pellet venting
or listed double wall pipe and Quadra-Fire
Outside Air Kit in mobile homes. Single
wall pipe is approved for residential instal-
lations only.
C. Vertical
D. Through The Wall & Vertical
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Noncombustible Hearth Pad
3 in. (76mm)
Min.
Cleanout Cover
24 in. (610mm)
Minimum
Ceiling Support
6 in. (152mm) Flue
Connector
6 in. (152mm) Class A
Chimney Connector
Adapter
3 in. to 6 in.
(76-152mm)
Top Vent Kit
Noncombustible Hearth Pad
Cleanout Cover
Tee
Wall Thimble
Support Bracket
every 60 in. (1524mm)
24 in. (610mm) minimum
Rain Cap
Flashing
2 in. (51mm) minimum
6 in. (152mm)
minimum
Figure 14.1
Figure 14.2