8
7019-230C
May 18, 2015
Santa Fe Pellet Insert
Fire Risk
Comply with all minimum clearances
to combustibles as specifi ed.
Failure to comply may cause house
fi re.
WARNING
NOTE:
•
Illustrations
refl ect typical installations and
are FOR DESIGN PURPOSES ONLY.
•
I
llustrations/diagrams are not drawn to
scale.
•
Actual installation may vary due to
individual design preference.
A
C
B
D
C
B
0 in. Clearance To Exposed Section And Face Trim
CL
B. Clearance To Combustibles, UL and ULC
Inches
Millimeters
A
Top of Hopper
Top Vent
2.0
51
Rear Vent
2.5
64
B
Side of Hopper
Top or Rear Vent
2.0
51
C
Back of Hopper
Top or Rear Vent
2.5
64
D
Vent Pipe to Combustible
Top or Rear Vent
3.0
76
12 in
(305mm)
Combustible
Mantel
6 in
(152mm)
Outside Air
Top Vent:
2 in. (51mm)
Rear Vent:
2.5 in (64mm)
Back of Hopper:
2.5 in (64mm)
Vent Pipe to
Combustibles:
3 in (76mm)
INSTALLED AS A BUILT-IN UNIT
Shown with Rear Vent and Optional Outside Air
Figure 8.1
Figure 8.2
AS A BUILT-IN