May 18, 2015
7019-230C
9
Santa Fe Pellet Insert
A
B
C
D
D. Minimum Opening for Masonry and Zero
Clearance Fireplaces
Inches
Millimeters
A
Insert side to combustible side wall
16
406
B
Insert top to mantel
12
305
C
Insert top to maximum. 2-1/4 inch (57mm)
face trim
4-3/4 121
D
Insert side to maximum. 2-1/4 inch (57mm)
face trim
10 254
Location
Inches
Millimeters
A
Rear Width
24
610
B
Depth
16
406
C
Height
23-1/4
591
D
Front Width
29-1/4
743
Figure 9.1
C. Masonry and Zero Clearance Fireplaces
Inches
Millimeters
E
Floor protection hearth extension from door
opening
6
152
F
Floor protection to the side of door opening
6
152
F. Floor Protection
Figure 9.2
Side W
a
ll
Mantel
Maximum Mantel Depth: 12 inches (305mm)
Face
Trim
E
F
A
D
C
B
NOTE
It is necessary to permanently seal any opening between
the masonry of the fi replace and the facing masonry.
E. Hearth Extension
If employing a hearth extension, any parts or materials used
in construction must be non-combustible.