Quadra-Fire • TOPAZ-MBK-IPI, TOPAZ-D-PMH-IPI, TOPAZ-D-MBK-IPI, TOPAZ-D-CSB-IPI Installation Manual • 2341-980_R10 • 11/15
28
EXHAUST VENT PIPE
INLET AIR VENT PIPE
Coaxial to Colinear Venting
The coaxial to colinear adapter (DV-46DVA-GCL) is
approved for installations into solid fuel masonry or factory
built fireplaces that have been installed in accordance with
the National, Provincial, State and local building codes.
Figure 4.29 Coaxial/Colinear Appliance Connector
WARNING! Risk of Fire!
Coaxial to colinear venting
configuration may only be used in existing non-
combustible chimney. Installation in any other venting
application could cause fire.
CAUTION! DO NOT use any flue restrictor when
venting with the DV-46DVA-GCL adapter and LINK-
DV30B kit.
This may result in poor flame appearance,
sooting, pilot malfunction, or overheating.
WARNING! Risk of Fire, Explosion or Asphyxiation!
Do NOT connect this gas appliance to a chimney flue
serving a separate solid fuel or gas burning appliance.
• May impair safe operation of this appliance or other
appliances connected to the flue.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.